Transballoon intravascular ultrasound imaging during balloon angioplasty in animal models with coarctation and branch pulmonary stenosisStock, John H... ...BACKGROUND: Intravascular ultrasound (IVUS) studies performed after balloon dilation provide a method for evaluating the adequacy of angioplastyature of associated changes in vessel walls. ... Previously, IVUS studies required the use of separate scanning catheters inserted independently before and after balloonangioplasty. We tested a 0.035-in, 30-MHz IVUS transducer wire that images from within commercially available 5F balloon dilation catheters. METHODS AND RESULTS: Seven stenoses were created in the left pulmonary artery (n = 3) and in the aortic isthmus (n = 4) in six lambs (weight, 3.4 to 12.5 kg). The balloon catheter selected was advanced across the stenotic area and the IVUS wire advanced in the guide lumen to the center of the balloon. Continuous IVUS images were obtained through balloons before, during, and after dilation. Transballoon imaging confirmed balloon location within the stenotic segment. Luminal diameters of stenotic and adjacent vessel segments before and after angioplasty by IVUS showed good correlation with angiographicmeasurements (r = .93, P less th. or = .001). After successful dilation, imaging during deflation allowed the assessment of vascular elastic recoil, mural dissection, and luminal size without requiring changes in balloon position. Repeat dilation could be undertaken and the inflation pressure and technique modified on the basis of the observed results. CONCLUSIONS: This transballoon IVUS system provides important on-line information about lumen diameter and wall structure for evaluation of angioplasty without the need for catheter changes, providing a method to possibly reduce the likelihood of excessive wall damage and to potentially reduce the number of angiograms required to accomplish and confirm results.Source: Circulation. - ISSN 0009-7322 (Let. 95, št. 10, 1997, str. 2354-2357)Type of material - article, component partPublish date - 1997Language - englishCOBISS.SI-ID - 7152089
Author
Stock, John H... |
Reller, Mark D... |
Sharma, Sanjeev |
Pavčnik, Dušan, 1948-2019 |
Shiota, Takahiro |
Sahn, David J...
Topics
Angioplasty, balloon |
Aortic coarctation |
Therapy |
Ultrasonography |
Radiography |
Pulmonary valve stenosis |
Therapy |
Ultrasonography |
Radiography |
Ultrasonography, interventional |
Angiography |
Animals, newborn |
Sheep
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|---|
Pavčnik, Dušan, 1948-2019 | 12718 |
Select pickup location:
Material pickup by post
Notification
Subject headings in COBISS General List of Subject Headings
Select pickup location
Pickup location | Material status | Reservation |
---|
Please wait a moment.