-
Multifragmentalni zlom nosne piramide in ukrivljen nosni pretin = Multi-fragmental fracture of the nasal pyramid and deviation of the nasal septumMunda, Anton ...Fractures of the nasal pyramid with dislocation cause changes in the statics, aesthetics and functions of the nose. Fracture of the bent cartilaginous nasalseptum and/or its bony frame releases ... intrinsic forces in the cartilage. Despite successful primary bone reduction, there can later be a progressive distortion of the quadrangular cartilage in the direction of the prevailing forces. As a consequence, the still unfixed bone fragments are pulled by theseforces, which results in a deformed appearance of the nose. Therefore, the best solution would be an excision-replacement reconstruction of the deformed nasal septum. After remodelling on the instrument-table (extracorporeal), all the available parts are reinserted and the septum is restored in the straight median position. As the septum goes, so goes the nose! The bony part of the nasal pyramid should be restored simultaneously with the restoration of the nasal septum.Source: Medicinski razgledi. Supplement. - ISSN 0353-3484 (Letn. 39, supl. 3, jun. 2000, str. 125-128)Type of material - article, component partPublish date - 2000Language - slovenianCOBISS.SI-ID - 11756505
Author
Munda, Anton |
Becner, Drago |
Čizmarevič, Bogdan |
Grošeta, Tomislav |
Žic, Rado |
Lanišnik, Boštjan |
Didanovič, Vojislav
Topics
Nasal bone |
Injuries |
Nasal septum |
Injuries |
Skull fractures |
Surgery |
Complications |
Diagnosis |
Cartilage |
Esthetics |
Patient selection |
Treatment outcome |
nos |
kosti |
poškodbe |
zlomi |
kirurško zdravljenje
![loading ... loading ...](themes/default/img/ajax-loading.gif)
source: Medicinski razgledi. Supplement. - ISSN 0353-3484 (Letn. 39, supl. 3, jun. 2000, str. 125-128)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|---|
Munda, Anton | ![]() |
Becner, Drago | ![]() |
Čizmarevič, Bogdan | 26175 |
Grošeta, Tomislav | ![]() |
Žic, Rado | 04088 |
Lanišnik, Boštjan | 32413 |
Didanovič, Vojislav | 28716 |
Select pickup location:
Material pickup by post
Notification
Subject headings in COBISS General List of Subject Headings
Select pickup location
Pickup location | Material status | Reservation |
---|
Please wait a moment.
Naročanje gradiva za izposojo v čitalnice
Naročanje kopij člankov
Urnik dostave gradiva z oznako DS v signaturi