Magnetic Resonance-guided radiotherapy (MRgRT) marks the beginning of a new era. MR is a versatile and suitable imaging modality for radiotherapy, as it enables direct visualization of the tumor and ...the surrounding organs at risk. Moreover, MRgRT provides real-time imaging to characterize and eventually track anatomical motion. Nevertheless, the successful translation of new technologies into clinical practice remains challenging. To date, the initial availability of next-generation hybrid MR-linac (MRL) systems is still limited and therefore, the focus of the present preview was on the initial applicability in current clinical practice and on future perspectives of this new technology for different treatment sites.MRgRT can be considered a groundbreaking new technology that is capable of creating new perspectives towards an individualized, patient-oriented planning and treatment approach, especially due to the ability to use daily online adaptation strategies. Furthermore, MRL systems overcome the limitations of conventional image-guided radiotherapy, especially in soft tissue, where target and organs at risk need accurate definition. Nevertheless, some concerns remain regarding the additional time needed to re-optimize dose distributions online, the reliability of the gating and tracking procedures and the interpretation of functional MR imaging markers and their potential changes during the course of treatment. Due to its continuous technological improvement and rapid clinical large-scale application in several anatomical settings, further studies may confirm the potential disruptive role of MRgRT in the evolving oncological environment.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
Patients with left-sided breast cancer frequently receive deep inspiration breath-hold (DIBH) radiotherapy to reduce the risk of cardiac side effects. The aim of the present study was to analyze ...intra-breath-hold stability and inter-fraction breath-hold reproducibility in clinical practice.
Overall, we analyzed 103 patients receiving left-sided breast cancer radiotherapy using a surface-guided DIBH technique. During each treatment session the vertical motion of the patient was continuously measured by a surface guided radiation therapy (SGRT) system and automated gating control (beam on/off) was performed using an audio-visual patient feedback system. Dose delivery was automatically triggered when the tracking point was within a predefined gating window. Intra-breath-hold stability and inter-fraction reproducibility across all fractions of the entire treatment course were analyzed per patient.
In the present series, 6013 breath-holds during beam-on time were analyzed. The mean amplitude of the gating window from the baseline breathing curve (maximum expiration during free breathing) was 15.8 mm (95%-confidence interval: 8.5-30.6 mm) and had a width of 3.5 mm (95%-CI: 2-4.3 mm). As a measure of intra-breath-hold stability, the median standard deviation of the breath-hold level during DIBH was 0.3 mm (95%-CI: 0.1-0.9 mm). Similarly, the median absolute intra-breath-hold linear amplitude deviation was 0.4 mm (95%-CI: 0.01-2.1 mm). Reproducibility testing showed good inter-fractional reliability, as the maximum difference in the breathing amplitudes in all patients and all fractions were 1.3 mm on average (95%-CI: 0.5-2.6 mm).
The clinical integration of an optical surface scanner enables a stable and reliable DIBH treatment delivery during SGRT for left-sided breast cancer in clinical routine.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
Intra-fraction motion represents a crucial issue in the era of precise radiotherapy in several settings, including breast irradiation. To date, only few data exist on real-time measured ...intra-fraction motion in breast cancer patients. Continuous surface imaging using visible light offers the capability to monitor patient movements in three-dimensional space without any additional radiation exposure. The aim of the present study was to quantify the uncertainties of possible intra-fractional motion during breast radiotherapy.
One hundred and four consecutive patients that underwent postoperative radiotherapy following breast conserving surgery or mastectomy were prospectively evaluated during 2028 treatment sessions. During each treatment session the patients' motion was continuously measured using the Catalyst™ optical surface scanner (C-RAD AB, Sweden) and compared to a reference scan acquired at the beginning of each session. The Catalyst system works through an optical surface imaging with light emitting diode (LED) light and reprojection captured by a charge coupled device (CCD) camera, which provide target position control during treatment delivery with a motion detection accuracy of 0.5 mm. For 3D surface reconstruction, the system uses a non-rigid body algorithm to calculate the distance between the surface and the isocentre and using the principle of optical triangulation. Three-dimensional deviations and relative position differences during the whole treatment fraction were calculated by the system and analyzed statistically.
Overall, the maximum magnitude of the deviation vector showed a mean change of 1.93 mm ± 1.14 mm (standard deviation SD) (95%-confidence interval: 0.48-4.65 mm) and a median change of 1.63 mm during dose application (beam-on time only). Along the lateral and longitudinal axis changes were quite similar (0.18 mm ± 1.06 mm vs. 0.17 mm ± 1.32 mm), on the vertical axis the mean change was 0.68 mm ± 1.53 mm. The mean treatment session time was 154 ± 53 (SD) seconds and the mean beam-on time only was 55 ± 16 s. According to Friedman's test differences in the distributions of the three possible directions (lateral, longitudinal and vertical) were significant (p < 0.01), in post-hoc analysis there were no similarities between any two of the three directions.
The optical surface imaging system is an accurate and easy tool for real-time motion management in breast cancer radiotherapy. Intra-fraction motion was reported within five millimeters in all directions. Thus, intra-fraction motion in our series of 2028 treatment sessions seems to be of minor clinical relevance in postoperative radiotherapy of breast cancer.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
Bladder cancer represents the most common type of urothelial carcinoma, with a median overall survival of 12.5–15 months in the case of metastatic disease. We evaluated the role of stereotactic body ...radiation therapy (SBRT) in the management oligometastatic urothelial cancer.
Data on patients with a maximum of five metastases were collected from three institutions. Concomitant systemic therapy was allowed. End points were the local control of treated metastases, distant progression-free survival (PFS), overall PFS and overall survival.
Data for 82 lesions and 61 patients were included. The primary tumour was located in the bladder in 82% of patients, followed by kidney pelvis (11.5%). The most common treated site was lung (40.2%). Twenty-nine (47.5%) and 14 (23%) patients received systemic therapy before and during SBRT, respectively. The median BED10 value was 78.7 Gy. The median follow-up was 17.2 months. Rates of local control at 1 and 2 years were 92% and 88.9%, respectively, with correlation with systemic therapy before SBRT (hazard ratio 2.62, P = 0.034). Overall PFS at 1 and 2 years was 47.9% and 38.1%, respectively. The number of metastases was a predictive factor (hazard ratio 2.65, P = 0.008). The median overall survival was 25.6 months. Total dose (hazard ratio 0.93, P = 0.003) and BED10 (hazard ratio 0.97, P = 0.006) were correlated with overall survival. No grade ≥2 adverse events were reported.
SBRT represents an effective and safe treatment in metastatic urothelial carcinoma. Prospective randomised trials are necessary to better evaluate the benefit on delaying the onset of new systemic therapies.
•Surgical approach for metastases from urothelial carcinoma is not always feasible, due to lesions' or patient's characteristics.•SBRT can be considered an effective non-invasive and well-tolerated local treatment.•Adoption of SBRT early in the management of oligometastatic urothelial carcinoma can improve disease control.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
•Spine SBRT yields greater complete/partial pain response rates than expected.•Spine SBRT is associated with high rates of local control.•∼10 % get post-SBRT vertebral compression fractures ...with < 2 % needing surgery.•Radiation myelopathy is rare with modern image-guided SBRT and evidence-based dose limits applied to the spinal cord.
Advances in characterizing cancer biology and the growing availability of novel targeted agents and immune therapeutics have significantly changed the prognosis of many patients with metastatic disease. Palliative radiotherapy needs to adapt to these developments. In this study, we summarize the available evidence for stereotactic body radiotherapy (SBRT) in the treatment of spinal metastases.
A systematic review and meta-analysis was performed using PRISMA methodology, including publications from January 2005 to September 2021, with the exception of the randomized phase III trial RTOG-0631 which was added in April 2023. Re-irradiation was excluded. For meta-analysis, a random-effects model was used to pool the data. Heterogeneity was assessed with the I2-test, assuming substantial and considerable as I2 > 50 % and I2 > 75 %, respectively. A p-value < 0.05 was considered statistically significant.
A total of 69 studies assessing the outcomes of 7236 metastases in 5736 patients were analyzed. SBRT for spine metastases showed high efficacy, with a pooled overall pain response rate of 83 % (95 % confidence interval CI 68 %-94 %), pooled complete pain response of 36 % (95 % CI: 20 %-53 %), and 1-year local control rate of 94 % (95 % CI: 86 %-99 %), although with high levels of heterogeneity among studies (I2 = 93 %, I2 = 86 %, and 86 %, respectively). Furthermore, SBRT was safe, with a pooled vertebral fracture rate of 9 % (95 % CI: 4 %-16 %), pooled radiation induced myelopathy rate of 0 % (95 % CI 0–2 %), and pooled pain flare rate of 6 % (95 % CI: 3 %-17 %), although with mixed levels of heterogeneity among the studies (I2 = 92 %, I2 = 0 %, and 95 %, respectively). Only 1.7 % of vertebral fractures required surgical stabilization.
Spine SBRT is characterized by a favorable efficacy and safety profile, providing durable results for pain control and disease control, which is particularly relevant for oligometastatic patients.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Purpose/Objective:
Reproducible patient positioning remains one of the major challenges in modern radiation therapy. Recently, optical surface scanners have been introduced into clinical practice in ...addition to well-established positioning systems, such as room laser and skin marks. The aim of this prospective study was to evaluate setup errors of the optical surface scanner Catalyst HD (C-RAD AB) in different anatomic regions.
Material/Methods:
Between October 2016 and June 2017 a total of 1902 treatment sessions in 110 patients were evaluated. The workflow of this study included conventional setup procedures using laser-based positioning with skin marks and an additional registration of the 3-dimensional (3D) deviations detected by the Catalyst system. The deviations of the surface-based method were then compared to the corrections of cone beam computed tomography alignment which was considered as gold standard. A practical Catalyst setup error was calculated between the translational deviations of the surface scanner and the laser positioning. Two one-sided t tests for equivalence were used for statistical analysis.
Results:
Data analysis revealed total deviations of 0.09 mm ± 2.03 mm for the lateral axis, 0.07 mm ± 3.21 mm for the longitudinal axis, and 0.44 mm ± 3.08 mm vertical axis for the Catalyst system, compared to −0.06 ± 3.54 mm lateral, 0.53 ± 3.47 mm longitudinal, and 0.19 ± 3.49 mm vertical for the laser positioning compared to cone beam computed tomography. The lowest positional deviations were found in the cranial region, and larger deviations occurred in the thoracic and abdominal sites. A statistical comparison using 2 one-sided t tests showed a general concordance of the 2 methods (P ≤ 0.036), excluding the vertical direction of the abdominal region (P = 0.198).
Conclusion:
The optical surface scanner Catalyst HD is a reliable and feasible patient positioning system without any additional radiation exposure. From the head to the thoracic and abdominal region, a decrease in accuracy was observed within a comparable range for Catalyst and laser-assisted positioning.
Recent progress in diagnostics and treatment of metastatic cancer patients have improved survival substantially. These developments also affect local therapies, with treatment aims shifting from ...short-term palliation to long-term symptom or disease control. There is consequently a need to better define the value of stereotactic body radiotherapy (SBRT) for the treatment of spinal metastases.
This ESTRO clinical practice guideline is based on a systematic literature review conducted according to PRISMA standards, which formed the basis for answering four key questions about the indication and practice of SBRT for spine metastases.
The analysis of the key questions based on current evidence yielded 22 recommendations and 5 statements with varying levels of endorsement, all achieving a consensus among experts of at least 75%. In the majority, the level of evidence supporting the recommendations and statements was moderate or expert opinion, only, indicating that spine SBRT is still an evolving field of clinical research. Recommendations were established concerning the selection of appropriate patients with painful spine metastases and oligometastatic disease. Recommendations about the practice of spinal SBRT covered technical planning aspects including dose and fractionation, patient positioning, immobilization and image-guided SBRT delivery. Finally, recommendations were developed regarding quality assurance protocols, including description of potential SBRT-related toxicity and risk mitigation strategies.
This ESTRO clinical practice guideline provides evidence-based recommendations and statements regarding the selection of patients with spinal metastases for SBRT and its safe implementation and practice. Enrollment of patients into well-designed prospective clinical trials addressing clinically relevant questions is considered important.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP