Exact localisation of thoracic lymph nodes (LNs) on fluorine-18 fluoro-2-deoxy-d-glucose positron emission tomography (FDG-PET) can be hampered by the paucity of anatomical landmarks. In non-small ...cell lung cancer (NSCLC) patients referred for locoregional LN staging, we prospectively examined to what extent localisation of LNs at PET reading could be improved by visual correlation with computed tomography (CT), or by anatometabolic PET+CT fusion images. Fifty-six patients with potentially operable NSCLC underwent CT, PET and surgical staging. Prospective reading was performed for CT, PET without CT, PET+CT visual correlation and PET+CT fusion. Reading was blinded to surgical pathology data and noted on a standard LN map. Surgical staging was available for 493 LN stations. In the evaluation per individual LN station, CT was accurate in 87%, PET in 91% and visual correlation and fusion in 93%. In the identification of the nodal stage, CT was correct in 28/56 patients (50%), PET in 37/56 (66%), visual correlation in 40/56 (71%), and fusion in 41/56 (73%). It is concluded that in the exact localisation of metastatic thoracic LNs, the accuracy of reading of PET is increased if the PET images can be visually correlated with CT images. PET+CT anatometabolic fusion images add only a marginal benefit compared with visual correlation.PUBLICATION ABSTRACT
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
We present high-resolution ultrasonography of a paraurethral cyst, a rare cause of an interlabial mass in a newborn. Although not always performed in these cases, ultrasonographic evaluation is an ...easily performed examination in assessment of the final diagnosis and therapeutic decisions.
Full text
Available for:
EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, VSZLJ, ZAGLJ
Gamma-ray bursts (GRBs) are highly energetic explosions signaling the death of massive stars in distant galaxies. The Gamma-ray Burst Monitor and Large Area Telescope onboard the Fermi Observatory ...together record GRBs over a broad energy range spanning about 7 decades of gamma-ray energy. In September 2008, Fermi observed the exceptionally luminous GRB 080916C, with the largest apparent energy release yet measured. The high-energy gamma rays are observed to start later and persist longer than the lower energy photons. A simple spectral form fits the entire GRB spectrum, providing strong constraints on emission models. The known distance of the burst enables placing lower limits on the bulk Lorentz factor of the outflow and on the quantum gravity mass.
Full text
Available for:
BFBNIB, NMLJ, NUK, PNG, SAZU, UL, UM, UPUK
Response of the GLAST LAT calorimeter to relativistic heavy ions Lott, B.; Piron, F.; Blank, B. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
05/2006, Volume:
560, Issue:
2
Journal Article
Peer reviewed
The CsI calorimeter of the Gamma-Ray Large-Area Space Telescope (GLAST) will be calibrated in flight with cosmic-ray heavy ions. In order to determine the response of the calorimeter to relativistic ...heavy ions lighter than Fe, an experiment was carried out at the GSI heavy ion facility using the Fragment Separator (FRS). The measured response exhibits an unexpected feature for light ions, opposite to that observed at low incident energy: for a given deposited energy, the observed signal is greater for these ions than for protons (or more generally
Z
=
1
minimum ionizing particles). Pulse shapes are found to be almost identical for carbon ions and
Z
=
1
particles, with a significant slow scintillation component, which constitutes another departure from the low-energy behavior. Data on the energy resolution for the individual CsI crystals and on the loss of ions due to nuclear reactions in the calorimeter are also presented.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
The energy response of plastic scintillators (Eljen Technology EJ-204) to polarized soft gamma-ray photons below 100
keV has been studied, primarily for the balloon-borne polarimeter, PoGOLite. The ...response calculation includes quenching effects due to low-energy recoil electrons and the position dependence of the light collection efficiency in a 20
cm long scintillator rod. The broadening of the pulse-height spectrum, presumably caused by light transportation processes inside the scintillator, as well as the generation and multiplication of photoelectrons in the photomultiplier tube, were studied experimentally and have also been taken into account. A Monte Carlo simulation based on the Geant4 toolkit was used to model photon interactions in the scintillators. When using the polarized Compton/Rayleigh scattering processes previously corrected by the authors, scintillator spectra and angular distributions of scattered polarized photons could clearly be reproduced, in agreement with the results obtained at a synchrotron beam test conducted at the KEK Photon Factory. Our simulation successfully reproduces the modulation factor, defined as the ratio of the amplitude to the mean of the distribution of the azimuthal scattering angles, within
∼
5
%
(relative). Although primarily developed for the PoGOLite mission, the method presented here is also relevant for other missions aiming to measure polarization from astronomical objects using plastic scintillator scatterers.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK