The diagnosis of acute rejection in cardiac transplant recipients requires invasive technique with endomyocardial biopsy (EMB) which has risks and limitations. Cardiovascular magnetic resonance ...imaging (CMR) with T2 and T1 mapping is a promising technique for characterizing myocardial tissue. The purpose of the study was to evaluate T2, T1 and extracellular volume fraction (ECV) quantification as novel tissue markers to diagnose acute rejection.
CMR was prospectively performed in 20 heart transplant patients providing 31 comparisons EMB-CMR. CMR was performed close to EMB. Images were acquired on a 1.5 Tesla scanner including T2 mapping (T2 prepared balanced steady state free precession) and T1 mapping (modified Look-Locker inversion recovery sequences: MOLLI) at basal, mid and apical level in short axis view. Global and segmental T2 and T1 values were measured before and 15 min (for T1 mapping) after contrast administration.
Acute rejection was diagnosed in seven patients: six cellular rejections (4 grade IR, 2 grade 2R) and one antibody mediated rejection. Patients with acute rejection had significantly higher global T2 values at 3 levels: 58.5 ms 55.0-60.3 vs 51.3 ms 49.5-55.2 (p = 0.007) at basal; 55.7 ms 54.0-59.7 vs 51.8 ms 50.1-53.6 (p = 0.002) at median and 58.2 ms 54.0-63.7 vs 53.6 ms 50.8-57.4 (p = 0.026) at apical level. The area under the curve (AUC) for each level was 0.83, 0.79 and 0.78 respectively. Patients with acute rejection had significantly higher ECV at basal level: 34.2% 32.8-37.4 vs 27.4% 24.6-30.6 (p = 0.006). The AUC for basal level was 0.84. The sensitivity, specificity and diagnosis accuracy for basal T2 (cut off: 57.7 ms) were 71, 96 and 90% respectively; and for basal ECV: (cut off 32%) were 86, 85 and 85% respectively. Combining basal T2 and basal ECV allowed diagnosing all acute rejection and avoiding 63% of EMB.
In heart transplant patients, a combined CMR approach using T2 mapping and ECV quantification provides a high diagnostic accuracy for acute rejection diagnosis and could potentially decrease the number of routine EMB.
Full text
Available for:
DOBA, GEOZS, IJS, IMTLJ, IZUM, KILJ, KISLJ, NLZOH, NUK, OILJ, PILJ, PNG, SAZU, SBCE, SBJE, UILJ, UKNU, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Forensic age estimation is a challenging field in forensic sciences because of the increase of migratory flows. Medicolegal age assessment is a key point because it has many implications for ...authorities. Dental age estimation is an essential part of the global age assessment. The aim of this study was to evaluate and test the accuracy of Cameriere’s cutoff values of the third molar maturity index (I3M) in assessing legal adult age of 18 years in a French population. The sample was constituted of 431 orthopantomograms performed between January 2014 and August 2017 on patients aged between 14 and 22 years. The reproducibility and repeatability of the method were high. Age distribution gradually decreases as I3M increases in both sexes. 0.08 seemed to be the best I3M cutoff. For females, the sensitivity and specificity of the test were 74.51% and 88.23%, respectively. The sensitivity and specificity for males were 92.19% and 88.35%, respectively. The accuracies were 80.74% for female, 90.57% for male. Estimated post-test probabilities were 0.879 for female and 0.899 for male. To conclude, the specific cutoff value of I3M ˂ 0.08 may be a useful additional tool in discriminating adults and minors in French population.
Purpose
Ultrasonographic quantitative measurements enable characterizing the stiffness and viscosity of liver parenchyma. Normal Shear Wave Elastography (SWE) values have been reported in adults and ...children. The Attenuation Imaging (ATI) coefficient is a measure of local sound energy loss thought to reflect steatosis in adults. The aim of our study was to provide normal SWE and ATI liver values in healthy children.
Methods
A prospective monocentric study was conducted recruiting 86 children (45 boys and 41 girls) from a single University Hospital between January 2019 and June 2020, having a clinically indicated ultrasound examination, without a known or documented history of liver disease. Examinations were performed using an Aplio i800 (Canon Medical Systems) ultrasound system with an i8CX1 transducer. SWE measurements were obtained using a color map showing an automated measurement area grid overlay. ATI coefficients were generated automatically for each region of interest in the right liver.
Results
Overall median age for the pediatric population was 106 months (1–180 months; SD 49 months). Children were normal weighted. Liver SWE was available for all children. The median liver SWE was 4.6 kPa 3.3–6.6. ATI yielded valid measurements in 77 patients. The median ATI coefficient was 0.65 0.5–0.81 dB/cm/MHz. No impact of age, sex, weight and Body Mass Index was observed.
Conclusion
SWE and ATI liver values were provided in healthy children. The normative quantitative data might be useful to characterize liver parenchyma in children better.
Full text
Available for:
EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, VSZLJ, ZAGLJ
Objectives
To develop technical guidelines for magnetic resonance imaging aimed at characterising renal masses (multiparametric magnetic resonance imaging, mpMRI) and at imaging the bladder and upper ...urinary tract (magnetic resonance urography, MRU).
Methods
The French Society of Genitourinary Imaging organised a Delphi consensus conference with a two-round Delphi survey followed by a face-to-face meeting. Two separate questionnaires were issued for renal mpMRI and for MRU. Consensus was strictly defined using a priori criteria.
Results
Forty-two expert uroradiologists completed both survey rounds with no attrition between the rounds. Fifty-six of 84 (67%) statements of the mpMRI questionnaire and 44/71 (62%) statements of the MRU questionnaire reached final consensus. For mpMRI, there was consensus that no injection of furosemide was needed and that the imaging protocol should include T2-weighted imaging, dual chemical shift imaging, diffusion-weighted imaging (use of multiple
b
-values; maximal
b
-value, 1000 s/mm
2
) and fat-saturated single-bolus multiphase (unenhanced, corticomedullary, nephrographic) contrast-enhanced imaging; late imaging (more than 10 min after injection) was judged optional. For MRU, the patients should void their bladder before the examination. The protocol must include T2-weighted imaging, anatomical fast T1/T2-weighted imaging, diffusion-weighted imaging (use of multiple
b
-values; maximal
b
-value, 1000 s/mm
2
) and fat-saturated single-bolus multiphase (unenhanced, corticomedullary, nephrographic, excretory) contrast-enhanced imaging. An intravenous injection of furosemide is mandatory before the injection of contrast medium. Heavily T2-weighted cholangiopancreatography-like imaging was judged optional.
Conclusion
This expert-based consensus conference provides recommendations to standardise magnetic resonance imaging of kidneys, ureter and bladder.
Key Points
• Multiparametric magnetic resonance imaging (mpMRI) aims at characterising renal masses; magnetic resonance urography (MRU) aims at imaging the urinary bladder and the collecting systems.
• For mpMRI, no injection of furosemide is needed.
• For MRU, an intravenous injection of furosemide is mandatory before the injection of contrast medium; heavily T2-weighted cholangiopancreatography-like imaging is optional.
This study evaluated the ability of T1 and T2 mapping cardiovascular magnetic resonance to assess myocardial involvement in Takotsubo syndrome (TTS). We hypothesized that non-contrast mapping ...techniques can be accurate and sufficient.
We prospectively analysed 30 patients with TTS and 34 controls. CMR was performed a mean 5 days after the onset of symptoms and after a mean 3 month follow-up.
On admission, compared to controls, TTS patients had significantly higher global T2 values (59 ± 8 ms vs 51 ± 4 ms, p < 0.001), native T1 (1053 ± 75 ms vs 960 ± 61 ms, p < 0.001) and extracellular volume (ECV) fraction (29% ± 5 vs 23% ±3, p < 0.001). The sensitivity and specificity for T2 (cut off: 56 ms) were 62% and 97% respectively; for native T1: (cut off 1011 ms) were 72% and 91% respectively; and for ECV (cut off: 27%) were 72% and 97% respectively. Combining T2 and native T1 provided the best sensitivity (91.7%) with a good specificity (88.2%). No patients had late gadolinium enhancement.
Segmental analysis showed that T2, native T1 and ECV values were significantly higher in regions with wall motion abnormalities (WMA) compared to normokinetic segments (62 ± 9 ms vs 55 ± 5 ms, p < 0.001; 1060 ± 65 ms vs 1025 ± 56 ms, p = 0.02; and 34% ± 5 vs 29% ± 1, p = 0.02). At follow up, native T1 and ECV values did not normalized.
In TTS patients, a non-contrast mapping technique provides a high diagnostic accuracy allowing identification of acute and persistent myocardial injury. Segmental analysis showed that myocardial injury is preferably detected in segments with WMA.
•Non-contrast mapping technique allows non-invasive quantification of acute myocardial injury in Takotsubo cardiomyopathy.•Native T1 mapping could diagnose persistent inflammation in TC.•Segments with wall motion abnormalities are more involved by the acute process than normokinetic segments.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
•Isolated camptocormia in a heterozygous carrier of the 759_761 CAPN3 deletion.•759_761 CAPN3 deletion causes loss of a single lysine in CAPN3 catalytic domain.•Lys254del CAPN3 abolishes both ...autolytic and proteolytic CAPN3 activity.•Consider dominant calpainopathy in the differential diagnosis of late camptocormia.
Camptocormia is defined by a pathological involuntary flexion of the thoracic and lumbar spine that is fully reducible in the supine position. Although originally described as a manifestation of conversion disorder, it is more commonly caused by a wide range of neurological diseases, in particular movement and neuromuscular disorders. We describe here a rare case of late onset camptocormia caused by autosomal dominant calpainopathy due to a heterozygous in-frame deletion in CAPN3 leading to loss of a single lysin amino acid in the catalytic domain of calpain-3. Creatine kinase levels, electromyography, and thigh muscle MRI were normal. Muscle biopsy did not show lobulated fibers and calpain-3 protein expression was not decreased, but in vitro functional assays showed impaired proteolytic function of. Lys254del CAPN3. Autosomal dominant calpainopathy should be considered in the differential diagnosis of late onset camptocormia and unexplained paravertebral myopathies even in presence of normal creatine kinase levels, and in absence of lobulated fibers, of decreased calpain-3 protein expression, and of muscle limb involvement.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Ultrasound is currently recommended as the first-line examination for abdominal symptoms in children. However, a pediatric radiologist is not always available on site, especially during on-call duty. ...This study was aimed at evaluating the reliability of an innovative 3-D virtual abdominal tele-ultrasonography in this context. A prospective study was conducted between December 2020 and May 2021 that recruited 103 children undergoing ultrasound for abdominal pain. Trauma cases were excluded. Four tridimensional acquisitions were performed with a Smart Sensor 3D device (Canon Medical Systems, Otawara, Japan). Each tele-ultrasonography was secondarily blindly reviewed by two radiologists (one senior and one resident) with Fusion software (Canon Medical Systems). Acceptance and quality of the acquisitions were evaluated on a Likert scale. Inter-rater reliability was quantified using Cohen's κ coefficient and intraclass correlation coefficient. The ultrasound examination was normal in 66 cases (64%), abnormal in 36 cases (35%) and inconclusive in 1 case (1%). The acquisitions were obtained without objections from the children, their parents or the operators in more than 95% of cases. The quality of the acquisitions was considered good to excellent in 84% and 70% of cases. The sensitivity of the senior radiologist and the resident was 86% and 84%, respectively; specificity was 95% and 92%, positive predictive value 92% and 86% and negative predictive value 92 and 91% when comparing the conclusions of the standard and the tele-ultrasound examinations. Cohen's κ coefficients of the diagnosis obtained with the standard and the tele-ultrasound examinations were 0.82 and 0.71, respectively. The inter-rater Cohen's κ coefficient was 0.84. The intraclass correlation coefficient between the standard abdominal examination and the 3-D tele-ultrasound reformatted images for the following quantitative variables on pathological cases was 0.99 (confidence interval: 0.98-0.99). Virtual abdominal tele-ultrasonography is a promising method in pediatric emergencies.
Background
Pediatric magnetic resonance imaging (MRI) and computed tompgraphy (CT) require patient immobility and therefore often require sedation or general anesthesia of patients. Consensus on ...these procedures is lacking in France.
Objective
Thus, the aim of this study was to describe the current sedation practices for pediatric MRI and CT in France.
Material and methods
From January 2019 to December 2019, an online questionnaire was delivered by electronic mail to a representative radiologist in 60 pediatric radiology centers registered by the French-speaking pediatric and prenatal imaging society. Questions included protocols, drugs used, monitoring and side effects.
Results
Representatives of 40 of the 60 (67%) radiology centers responded to the survey. Among them, 31 performed sedation including 17 (55%) centers where radiologists performed sedation without anesthesiologists present during the procedure. The premedication drugs were hydroxyzine (
n
= 8, 80%) and melatonin (
n
= 2, 20%), Sedation drugs used for children ages 0 to 6 years old were pentobarbital (
n
= 9, 60%), midazolam (
n
= 2, 13%), chloral hydrate (
n
= 2, 13%), diazepam (
n
= 1, 6.5%) and chlorpromazine (
n
= 1, 6.5%). A written sedation protocol was available in 10/17 (59%) centers. In 6/17 (35%) centers, no monitoring was used during the procedures. Blood pressure monitoring and capnography were rarely used (< 10%) and post-sedation monitoring was heterogeneous. No life-threatening adverse effect was reported, but 6 centers reported at least one incident per year.
Conclusion
For half of the responding radiology centers, radiologists performed sedation alone in agreement with the local anesthesiology team. Sedation procedures and monitoring were heterogenous among centers. Adjustment and harmonization of the practices according to the capacity of each center may be useful.
Full text
Available for:
EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, VSZLJ, ZAGLJ
Abstract
Pelvis radiography is a frequent X-ray examination. The objective of our study was to determine the minimum dose to be delivered without reducing the quality. We included 60 children having ...a pelvis X-ray in four groups that were equally represented by weight ranges. A software simulated, for each radiograph, six additional simulated photonic noise images corresponding to 100, 80, 64, 50, 40 and 32% of the initial dose. The 360 radiographs were blindly scored by two radiologists using a semi-quantitative Likert scale. There was no significant difference in scoring between the reference radiograph and simulated radiographs at 80% of the dose in children between 0 and 15 kg and over 35 kg. Inter-observer reproducibility was moderate to very good. Pelvis X-ray doses might be reduced by 20% in children in our institution. Software that produces simulated X-ray with decreasing dose might be a useful tool for an optimization process.