The Recoil Directionality (ReD) Experiment Sanfilippo, S; Agnes, P; Albergo, S ...
Journal of physics. Conference series,
11/2022, Volume:
2374, Issue:
1
Journal Article
Peer reviewed
Open access
Directional sensitivity to nuclear recoils would provide a smoking gun for a possible discovery of dark matter in the form of WIMPs (Weakly Interacting Massive Particles). A hint of directional ...dependence of the response of a dual-phase argon Time Projection Chamber (TPC) was found in the SCENE experiment. Given the potential importance of such a capability in the framework of dark matter searches, a new dedicated experiment, ReD (Recoil Directionality), was designed by the Global Argon Dark Matter Collaboration, in order to scrutinize this hint. Prior to the irradiation with a neutron beam, the ReD TPC underwent a long campaign of characterization and optimization: some selected results are presented in this contribution.
Large-area PhotoMultiplier Tubes (PMT) allow to efficiently instrument Liquid Scintillator (LS) neutrino detectors, where large target masses are pivotal to compensate for neutrinos' extremely ...elusive nature. Depending on the detector light yield, several scintillation photons stemming from the same neutrino interaction are likely to hit a single PMT in a few tens/hundreds of nanoseconds, resulting in several photoelectrons (PEs) to pile-up at the PMT anode. In such scenario, the signal generated by each PE is entangled to the others, and an accurate PMT charge reconstruction becomes challenging. This manuscript describes an experimental method able to address the PMT charge reconstruction in the case of large PE pile-up, providing an unbiased charge estimator at the permille level up to 15 detected PEs. The method is based on a signal filtering technique (Wiener filter) which suppresses the noise due to both PMT and readout electronics, and on a Fourier-based deconvolution able to minimize the influence of signal distortions—such as an overshoot. The analysis of simulated PMT waveforms shows that the slope of a linear regression modeling the relation between reconstructed and true charge values improves from 0.769±0.001 (without deconvolution) to 0.989±0.001 (with deconvolution), where unitary slope implies perfect reconstruction. A C++ implementation of the charge reconstruction algorithm is available online at 1.
We present the results of a search for dark matter weakly interacting massive particles (WIMPs) in the mass range below 20 GeV/c^{2} using a target of low-radioactivity argon with a 6786.0 kg d ...exposure. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso. The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detector at 0.5 keVee is about 1.5 event/keVee/kg/d and is almost entirely accounted for by known background sources. We obtain a 90% C.L. exclusion limit above 1.8 GeV/c^{2} for the spin-independent cross section of dark matter WIMPs on nucleons, extending the exclusion region for dark matter below previous limits in the range 1.8-6 GeV/c^{2}.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UL, UM
We present new constraints on sub-GeV dark-matter particles scattering off electrons based on 6780.0 kg d of data collected with the DarkSide-50 dual-phase argon time projection chamber. This ...analysis uses electroluminescence signals due to ionized electrons extracted from the liquid argon target. The detector has a very high trigger probability for these signals, allowing for an analysis threshold of three extracted electrons, or approximately 0.05 keVee. We calculate the expected recoil spectra for dark matter-electron scattering in argon and, under the assumption of momentum-independent scattering, improve upon existing limits from XENON10 for dark-matter particles with masses between 30 and 100 MeV/c^{2}.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UL, UM
The Belle II Physics Book Kou, E; Bishara, F; Brod, J ...
Progress of theoretical and experimental physics,
12/2019, Volume:
2019, Issue:
12
Journal Article
Peer reviewed
Open access
We present the physics program of the Belle II experiment, located on the intensity frontier SuperKEKB e+e- collider. Belle II collected its first collisions in 2018, and is expected to operate for ...the next decade. It is anticipated to collect 50/ab of collision data over its lifetime. This book is the outcome of a joint effort of Belle II collaborators and theorists through the Belle II theory interface platform (B2TiP), an effort that commenced in 2014. The aim of B2TiP was to elucidate the potential impacts of the Belle II program, which includes a wide scope of physics topics: B physics, charm, tau, quarkonium, electroweak precision measurements and dark sector searches. It is composed of nine working groups (WGs), which are coordinated by teams of theorist and experimentalists conveners: Semileptonic and leptonic B decays, Radiative and Electroweak penguins, φ1 and φ2 (time-dependent CP violation) measurements, φ3 measurements, Charmless hadronic B decay, Charm, Quarkonium(like), tau and low-multiplicity processes, new physics and global fit analyses. This book highlights "golden- and silver-channels", i.e. those that would have the highest potential impact in the field. Theorists scrutinised the role of those measurements and estimated the respective theoretical uncertainties, achievable now as well as prospects for the future. Experimentalists investigated the expected improvements with the large dataset expected from Belle II, taking into account improved performance from the upgraded detector.
We present a search for the direct production of a light pseudoscalar a decaying into two photons with the Belle II detector at the SuperKEKB collider. We search for the process e+e−→γa, a→γγ in the ...mass range 0.2<ma<9.7 GeV/c2 using data corresponding to an integrated luminosity of (445±3) pb−1. Light pseudoscalars interacting predominantly with standard model gauge bosons (so-called axionlike particles or ALPs) are frequently postulated in extensions of the standard model. We find no evidence for ALPs and set 95% confidence level upper limits on the coupling strength gaγγ of ALPs to photons at the level of 10−3 GeV−1. The limits are the most restrictive to date for 0.2<ma<1 GeV/c2.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UL, UM
.
Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid ...Argon Time Projection Chamber (LAr TPC) with an active (fiducial) mass of 23 t (20 t). This paper describes a preliminary design for the experiment, in which the DarkSide-20k LAr TPC is deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). This preliminary design provides a baseline for the experiment to achieve its physics goals, while further development work will lead to the final optimization of the detector parameters and an eventual technical design. Operation of DarkSide-50 demonstrated a major reduction in the dominant
39
Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of
>
3
×
10
9
is achievable. This, along with the use of the veto system and utilizing silicon photomultipliers in the LAr TPC, are the keys to unlocking the path to large LAr TPC detector masses, while maintaining an experiment in which less than
<
0
.
1
events (other than
ν
-induced nuclear recoils) is expected to occur within the WIMP search region during the planned exposure. DarkSide-20k will have ultra-low backgrounds than can be measured
in situ
, giving sensitivity to WIMP-nucleon cross sections of
1
.
2
×
10
-
47
cm
2
(
1
.
1
×
10
-
46
cm
2
) for WIMPs of 1 TeV/c
2
(10 TeV/c
2
) mass, to be achieved during a 5 yr run producing an exposure of 100 t yr free from any instrumental background.
Full text
Available for:
EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NLZOH, NUK, OBVAL, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
We present a search for dark matter particles with sub-GeV/c^{2} masses whose interactions have final state electrons using the DarkSide-50 experiment's (12 306±184) kg d low-radioactivity liquid ...argon exposure. By analyzing the ionization signals, we exclude new parameter space for the dark matter-electron cross section σover ¯_{e}, the axioelectric coupling constant g_{Ae}, and the dark photon kinetic mixing parameter κ. We also set the first dark matter direct-detection constraints on the mixing angle |U_{e4}|^{2} for keV/c^{2} sterile neutrinos.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UL, UM
Theories beyond the standard model often predict the existence of an additional neutral boson, the Z^{'}. Using data collected by the Belle II experiment during 2018 at the SuperKEKB collider, we ...perform the first searches for the invisible decay of a Z^{'} in the process e^{+}e^{-}→μ^{+}μ^{-}Z^{'} and of a lepton-flavor-violating Z^{'} in e^{+}e^{-}→e^{±}μ^{∓}Z^{'}. We do not find any excess of events and set 90% credibility level upper limits on the cross sections of these processes. We translate the former, in the framework of an L_{μ}-L_{τ} theory, into upper limits on the Z^{'} coupling constant at the level of 5×10^{-2}-1 for M_{Z^{'}}≤6 GeV/c^{2}.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UL, UM
The next-generation of all-sky EAS detector will be able to lower the threshold below the TeV region and will provide a huge data flux, due to the large detecting area and the high duty cycle. In ...this paper we discuss in detail the possibility of using this detector in order to study the cosmic ray spectrum in the TeV region. The peculiarities of this class of next-generation detectors will make it possible to study the energy profile in the region where direct measurements are available with a large statistical significance. In such a way the measurement obtained by an indirect technique can be fully overlapped with direct measurement data, in order not only to study the cosmic ray spectrum but also to investigate the reliability of the full Monte Carlo simulation process. The sensitivity of such a measurement is also discussed and the data taking time required for a significative measurement is estimated. A standard chi-square fit and a Bayesian unfolding procedure are applied in order to obtain a measurement of the spectral index of the incoming primaries.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK