Abstract
The current work presents the optimization of large area silicon drift detectors developed by the SIDDHARTA-2 collaboration for high precision x-ray measurements of light exotic atom ...transitions. Two different radiation sources were employed in the study: an x-ray tube, for investigating the energy resolution and the charge collection efficiency of the device in the range 4000 eV–13 000 eV, and a
β
−
90
Sr radioactive source for measuring the timing response, thus qualifying the charge drift parameters inside the semiconductor. The study reports the spectroscopic response optimization, together with the tuning of the electron dynamics for the given Silicon technology, by adjusting the applied electric field and the working temperature, which allow a good control of the device’s performances for high precision, timed x-ray spectroscopy applications.
The K¯N system at threshold is a sensitive testing ground for low energy QCD, especially for the explicit chiral symmetry breaking. Therefore, we have measured the K-series X-rays of kaonic hydrogen ...atoms at the DAΦNE electron–positron collider of Laboratori Nazionali di Frascati, and have determined the most precise values of the strong-interaction energy-level shift and width of the 1s atomic state. As X-ray detectors, we used large-area silicon drift detectors having excellent energy and timing resolution, which were developed especially for the SIDDHARTA experiment. The shift and width were determined to be ϵ1s=−283±36(stat)±6(syst) eV and Γ1s=541±89(stat)±22(syst) eV, respectively. The new values will provide vital constraints on the theoretical description of the low-energy K¯N interaction.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
Abstract
The SIDDHARTA-2 experiment at the DAΦNE collider aims to perform the first kaonic deuterium x-ray transitions to the fundamental level measurement, with a systematic error at the level of a ...few eV. To achieve this challenging goal the experimental apparatus is equipped with 384 Silicon Drift Detectors (SDDs) distributed around its cryogenic gaseous target. The SDDs developed by the SIDDHARTA-2 collaboration are suitable for high precision kaonic atoms spectroscopy, thanks to their high energy and time resolutions combined with their radiation hardness. The energy response of each detector must be calibrated and monitored to keep the systematic error, due to processes such as gain fluctuations, at the level of 2–3 eV. This paper presents the SIDDHARTA-2 calibration method which was optimized during the preliminary phase of the experiment in the real background conditions of the DAΦNE collider, which is a fundamental tool to guarantee the high precision spectroscopic performances of the system over long periods of data taking, as that required for the kaonic deuterium measurement.
The VIolation of Pauli exclusion principle -2 experiment, or VIP-2 experiment, at the Laboratori Nazionali del Gran Sasso searches for X-rays from copper atomic transitions that are prohibited by the ...Pauli exclusion principle. Candidate direct violation events come from the transition of a 2p electron to the ground state that is already occupied by two electrons. From the first data taking campaign in 2016 of VIP-2 experiment, we determined a best upper limit of Formula omitted for the probability that such a violation exists. Significant improvement in the control of the experimental systematics was also achieved, although not explicitly reflected in the improved upper limit. By introducing a simultaneous spectral fit of the signal and background data in the analysis, we succeeded in taking into account systematic errors that could not be evaluated previously in this type of measurements.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Abstract
The SIDDHARTINO experiment at the DAΦNE collider of INFN-LNF, the pilot run for the SIDDHARTA-2 experiment which aims to perform the measurement of kaonic deuterium transitions to the ...fundamental level, has successfully been concluded in July 2021. The paper reports the main results of this run, including the optimization of various components of the apparatus, among which the degrader needed to maximize the fraction of kaons stopped inside the target, through measurements of kaonic helium transitions to the 2p level. The obtained shift and width values are
ε
2p
=
E
exp
−
E
e.m
= 0.2 ± 2.5(stat) ± 2.0(syst) eV and Γ
2p
= 8 ± 10 eV (stat), respectively. This new measurement of the shift, in particular, represents the most precise one for a gaseous target and is expected to contribute to a better understanding of the kaon–nuclei interaction at low energy. The results obtained in this pilot run, combined with the foreseen additional veto systems and projected for the total 48 SDD arrays of the SIDDHARTA-2 final setup, represent a solid starting point for the successful measurement of the kaonic deuterium 2p → 1s transition, main goal of the experiment.
The VIolation of Pauli exclusion principle -2 experiment, or VIP-2 experiment, at the Laboratori Nazionali del Gran Sasso searches for X-rays from copper atomic transitions that are prohibited by the ...Pauli exclusion principle. Candidate direct violation events come from the transition of a 2
p
electron to the ground state that is already occupied by two electrons. From the first data taking campaign in 2016 of VIP-2 experiment, we determined a best upper limit of
3.4
×
10
-
29
for the probability that such a violation exists. Significant improvement in the control of the experimental systematics was also achieved, although not explicitly reflected in the improved upper limit. By introducing a simultaneous spectral fit of the signal and background data in the analysis, we succeeded in taking into account systematic errors that could not be evaluated previously in this type of measurements.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Abstract In this paper we present the results of a new kaonic helium-4 measurement with a 1.37 g l −1 gaseous target by the SIDDHARTA-2 experiment at the DAΦNE collider. We measured, for the first ...time, the energies and yields of three transitions belonging to the M-series. Moreover, we improved by a factor about three, the statistical precision of the 2p level energy shift and width induced by the strong interaction, obtaining the most precise measurement for gaseous kaonic helium, and measured the yield of the L α transition at the employed density, providing a new experimental input to investigate the density dependence of kaonic atoms transitions yield.
The most important information still missing in the field of the low-energy antikaon-nucleon inter actions studies is the experimental determination of the hadronic energy shift and width of kaonic ...deuterium. This measurement will be performed by the SIDDHARTA-2 experiment, installed at the DAΦNE collider and presently in data taking campaign. The precise measurement of the shift and width of the 1s level with respect to the purely electromagnetic calculated values, generated by the presence of the strong interaction, through the measurement of the X-ray transitions to this level, in kaonic hydrogen, was performed by the SIDDHARTA collaboration, the kaonic deuterium is underway by SIDDHARTA-2. These measurement will allow the first precise experimental extraction of the isospin dependent antikaon-nucleon scattering lengths, funda mental quantities for understanding low-energy QCD in the strangeness sector. The experimental challenge of the kaonic deuterium measurement is the very small X-rays yield, the even larger width (compared to kaonic hy drogen), and the difficulty to perform X-rays spectroscopy with weak signals in the high radiation environment of DAΦNE. It was, therefore, crucial to develop a new apparatus involving large-area X-rays detector system, to optimize the signal and to control and by improve the signal-to-background ratio by gaining in solid angle, increasing the timing capability, and as well implementing additional charge particle tracking veto systems.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
KAMEO (Kaonic Atoms Measuring Nuclear Resonance Effects Ob-servables) is a proposal for an experiment aiming to perform the first consistent measurement of the E2 nuclear resonance effects in kaonic ...molybdenum A=94,96,98,100 isotopes. The E2 nuclear resonance mixes atomic states, due to the electrical quadrupole excitation of nuclear rotational states. It occurs in atoms having the energy of a nuclear excitation state closely matching an atomic de-excitation state energy, and affects the rates of X-ray atomic transitions matching the energy of the resonance. The measurement E2 nuclear resonance effect in KMO isotopes allows the study of the strong kaon-nucleus interaction in a rotational excited nuclear state. Moreover, the effect enables the K - to access an inner atomic level not easily reachable by the kaon normal cascade, due to the nuclear absorption. The KAMEO proposed apparatus consists of 4 enriched Mo A=94,96,98,100 isotope strips, exposed to the kaons produced by the DAφNE collider, for kaonic atoms formation, with a high-purity germanium detector, cooled with liquid nitrogen, used to measure the X-ray atomic transitions. The DAφNE collider is located at the National Laboratories of Frascati (LNF-INFN), in Italy. It is already suited for kaonic atoms measurement by the SIDDHARTA-2 collaboration.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK