Sinus of Valsalva Pseudoaneurysm Centemero, Marinella; Urdanetta, Luis Rafael; Maschiarelli, Ibraim ...
JACC. Case reports,
05/2023, Volume:
14
Journal Article
Peer reviewed
Open access
We present a case of a young man with complete atrioventricular block and aneurysm of the right sinus of Valsalva penetrating the interventricular septum and causing severe aortic regurgitation. ...Chest trauma and inflammatory or infectious diseases are potential causes. Bentall–de Bono surgical repair was performed. Anatomopathologic analysis demonstrated fibrosis, hyalinization, and extensive myxoid material. (Level of Difficulty: Beginner.)
Display omitted
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
The ZoMaxx Coronary Stent System elutes the antiproliferative agent zotarolimus via a biocompatible phosphorylcholine polymer loaded onto a novel, thin, stainless steel stent platform containing an ...0.0007-inch inner layer of tantalum that enhances fluoroscopic radiopacity. The objective of this single-arm prospective clinical trial was to assess the safety and performance of the ZoMaxx stent for the treatment of coronary artery stenosis. Forty consecutive patients with ischemic coronary occlusive disease due to single de novo obstructive lesions of native coronary arteries were treated with 3 × 18 mm ZoMaxx stents at the Dante Pazzanese de Cardiologie in Saõ Paulo, Brazil, between April and July 2005. Independent core laboratories analyzed quantitative coronary angiography and intravascular ultrasound results immediately after stent implantation, and after 4 months. The lesion, procedure, and device-deployment success rates were all 100% (40 of 40). There were no major adverse cardiac events during the study. Follow-up quantitative coronary angiography at 4 months revealed in-stent and in-segment late lumen losses of 0.20 ± 0.35 and 0.17 ± 0.35 mm, respectively. Follow-up intravascular ultrasound at 4 months revealed 6.5 ± 6.2% neointimal volume obstruction. There were no instances of late acquired stent incomplete apposition or stent thrombosis. In conclusion, the ZoMaxx Coronary Stent can be safely implanted for the treatment of de novo coronary artery stenosis. The inhibition of neointima formation as measured by follow-up angiography and IVUS after 4 months suggests therapeutic potential for the reduction of restenosis.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
Background Lately drug-eluting stents (DES) have dramatically reduced restenosis rates and need for repeat revascularization in a wide subset of lesion and patients. However, their benefit for the ...treatment of large vessels (>3.0 mm) has yet to be established. Objective We investigated whether DES are superior to bare metal stents (BMS) in terms of clinical outcomes for the treatment of large coronary vessels. Methods This study assessed the long-term outcomes (cardiac death, acute myocardial infarction, and need for repeat intervention in the treated vessel) of patients treated with either a DES (Cypher and Taxus) or a BMS of ≥3.5 mm in diameter. A total of 250 consecutive patients who underwent DES implantation were clinically followed for 1 year and compared to 250 patients who were treated with BMS. Interventions in the setting of acute ST elevation myocardial infarction and treatment of bypass grafts were excluded. Results Cypher was the DES deployed in 70.8% of cases. Most of the enrolled patients were men (78%) with single vessel disease (65.6%). The left anterior descending artery was the culprit vessel in 34.2% of cases. Bare metal stent and DES cohorts had equivalent interpolated reference vessel diameter (3.19 ± 0.3 mm for BMS vs 3.18 ± 0.2 for DES; P = .1). Lesion was significantly longer in the group treated with DES (13.4 ± 5.1 mm for BMS group vs 14.3 ± 3.5 for DES; P = .0018). After 1 year of clinical follow-up, 95.2% of patients treated with DES and 91.2% of the patients who received BMS were free of major events ( P = .2). A trend toward higher target-lesion revascularization was noticed in the group treated with BMS (4.8% vs 1.6%; P = .07). Conclusion Percutaneous treatment of large coronary vessels carries a low risk of clinical events irrespective of the type of stent used.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
Bioresorbable vascular scaffolds (BVS) were developed to improve the long-term results of percutaneous coronary intervention, restoring vasomotion.
To report very late follow-up of everolimus-eluting ...Absorb BVS (Abbott Vascular, Santa Clara, USA) in our center.
Observational retrospective study, in a single Brazilian center, from August 2011 to October 2013, including 49 patients submitted to Absorb BVS implantation. Safety and efficacy outcomes were analyzed in the in-hospital and very late follow-up phases (> 2 years).
All 49 patients underwent a minimum follow-up of 2.5 years and a maximum of 4.6 years. Mean age was 56.8 ± 7.6 years, 71.4% of the patients were men, and 26.5% were diabetic. Regarding clinical presentation, the majority (94%) had stable angina or silent ischemia. Device success was achieved in 100% of cases with 96% overall procedure success rate. Major adverse cardiovascular events rate was 4% at 30 days, 8.2% at 1 year, and 12.2% at 2 years, and there were no more events until 4.6 years. There were 2 cases of thrombosis (1 subacute and 1 late).
In this preliminary analysis, Absorb BVS showed to be a safe and effective device in the very late follow-up. Establishing the efficacy and safety profiles of these devices in more complex scenarios is necessary.
Os suportes vasculares bioabsorvíveis (SVB) foram desenvolvidos com o intuito de melhorar os resultados da intervenção coronária percutânea a longo prazo, restabelecendo-se a vasomotricidade.
Reportar o seguimento muito tardio do implante do SVB eluidor de everolimus Absorb® (Abbot Vascular, Santa Clara, EUA) em nosso centro.
Estudo observacional, retrospectivo, em um único centro brasileiro, que incluiu 49 pacientes submetidos ao implante do SVB Absorb® entre agosto/2011 e outubro/2013. Foram analisados os desfechos de segurança e eficácia na fase hospitalar e bastante tardia (> 2 anos).
Todos os 49 pacientes completaram um seguimento mínimo de 2,5 anos, sendo o máximo de 4,6 anos. A média de idade foi 56,8 ± 7,6 anos, sendo 71,4% da população estudada do sexo masculino e 26,5% composta por diabéticos. Considerando a apresentação clínica, a grande maioria (94%) tinha angina estável ou isquemia silenciosa. Obteve-se sucesso do dispositivo em 100% dos casos e do procedimento, em 96%. A taxa de eventos cardiovasculares maiores foi de 4% aos 30 dias, de 8,2% em 1 ano, e de 12,2% em 2 anos, sem mais eventos até 4,6 anos. Houve 2 casos de trombose (1 subaguda e 1 tardia) até o último seguimento.
Nesta análise preliminar, o uso do SVB Absorb® mostrou-se seguro e eficaz no seguimento bastante tardio. Faz-se necessário estabelecer o perfil de eficácia e segurança destes dispositivos em cenários de maior complexidade.
Despite the potential benefits of percutaneous procedures for the assessment and treatment of coronary artery disease, these interventions require the use of iodine contrast, which might lead to ...contrast-induced nephropathy (CIN) and increased risk of dialysis and major adverse cardiac events (MACE).
We sought to compare two different iodine contrasts (low vs. iso-osmolar) for the prevention of CIN among high-risk patients.
This is a single-center, randomized (1:1) trial comparing consecutive patients at high risk for CIN referred to percutaneous coronary diagnostic and/or therapeutic procedures with low (ioxaglate) vs. iso-osmolarity (iodixanol) iodine contrast. High risk was defined by the presence of at least one of the following conditions: age >70 years, diabetes mellitus, non-dialytic chronic kidney disease, chronic heart failure, cardiogenic shock, and acute coronary syndrome (ACS). The primary endpoint was the occurrence of CIN, defined as a >25% relative increase and/or >0.5 mg/dL absolute increase in creatinine (Cr) levels compared with baseline between the 2nd and 5th day after contrast media administration.
A total of 2,268 patients were enrolled. Mean age was 67 years. Diabetes mellitus (53%), non-dialytic chronic kidney disease (31%), and ACS (39%) were highly prevalent. The mean volume of contrast media was 89 ml ± 48.6. CIN occurred in 15% of all patients, with no significant difference regarding the type of contrast used (iso = 15.2% vs. low = 15.1%, P>.99). Differences were not observed in specific subgroups such as diabetics, elderly, and ACS patients. At 30-day follow-up, 13 patients in the iso-osmolarity group and 11 in low-osmolarity group required dialysis (P =.8). There were 37 (3.3%) deaths in the iso-osmolarity cohort vs. 29 (2.6%) in the low-osmolarity group (P =.4).
Among patients at high risk for CIN, the incidence of this complication was 15%, and independent of the use of low- or iso-osmolar contrast.
We present a case of a young man with complete atrioventricular block and aneurysm of the right sinus of Valsalva penetrating the interventricular septum and causing severe aortic regurgitation. ...Chest trauma and inflammatory or infectious diseases are potential causes. Bentall-de Bono surgical repair was performed. Anatomopathologic analysis demonstrated fibrosis, hyalinization, and extensive myxoid material. (
).
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP