Aerogel Cherenkov counters for the KEDR detector Barnyakov, M.Yu; Bobrovnikov, V.S; Buzykaev, A.R ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
10/2000, Volume:
453, Issue:
1
Journal Article
Peer reviewed
The project of Cherenkov counters based on Aerogel, wavelength SHIfter, and PHotomultiplier (ASHIPH) for the KEDR detector is described. The Monte Carlo simulation of number of photoelectrons was ...carried out. The first counters have been produced. Measurements with cosmic particles were performed. As compared with the direct light collection on PMT, the ASHIPH method allows the diminishment of the number of PMTs essentially. The optical properties of aerogels produced at KEK and at Novosibirsk are presented.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
42.
ASHIPH counters for the KEDR detector Barnyakov, A.Yu; Barnyakov, M.Yu; Bobrovnikov, V.S ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
11/2002, Volume:
494, Issue:
1
Journal Article
Peer reviewed
The status of the ASHIPH (Aerogel, wavelength SHIfter, and PHotomultipliers) system of the KEDR detector is described. The measurement of the quality of the particle identification with the ASHIPH ...counters was performed. The π/K separation is 4.5
σ for the momentum
1.2
GeV/c
and 4.7
σ for the momentum
0.86
GeV/c
. Timing properties of the ASHIPH counter are measured. The time resolution for pions is
2
ns
, and the BBQ decay time is
15
ns
. The advantages and disadvantages of Cherenkov counters filled with aerogel crumb are discussed. The process of the mass counter production for the KEDR detector is described.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
We report on the results obtained using thick samples of silica aerogel as radiators for a Ring Imaging Cherenkov counter. Four large-diameter hybrid photodiodes with 2048 channels have been used as ...photon detectors. Pions and protons with momenta ranging from 6 to 10GeV/c were separated and identified. The number of photoelectrons and the radius of the Cherenkov rings together with the Cherenkov angle resolution were measured. A comparison with a simulation program based on GEANT4 is discussed.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
46.
The status of the KEDR ASHIPH system Barnyakov, A.Yu; Barnyakov, M.Yu; Bobrovnikov, V.S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2004, Volume:
518, Issue:
1
Journal Article
Peer reviewed
Cherenkov counters based on Aerogel, wavelength SHIfter, and PHotomultipliers (ASHIPH) for the KEDR detector are described. As compared with the direct light collection on PMT, the ASHIPH method ...allows us to diminish the number of PMTs essentially. The quality of the particle identification with the ASHIPH counters was tested. The π/K separation is 4.5
σ for the momentum
1.2
GeV/c
. The mass production of the ASHIPH counters was organized in Budker Institute of Nuclear Physics (Novosibirsk, Russia). 80 counters filled with
500
ls
of aerogel have been produced and tested with cosmic muons. These counters were installed into the KEDR detector in 2003. The stability of the micro-channel PMTs without protecting layer was studied. The first results on a long-term stability of the ASHIPH counters filled with the hygroscopic aerogel are presented.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
47.
FARICH optimization for precise velocity measurement Barnyakov, A.Yu; Barnyakov, M.Yu; Bobrovnikov, V.S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
2009, 2009-1-00, Volume:
598, Issue:
1
Journal Article
Peer reviewed
Lately aerogel samples of refractive index as high as 1.13 were synthesized in Novosibirsk. Light scattering length for some samples approaches 12
cm.
We performed a Geant4 simulation for a FARICH ...with aerogel of 1.10 index of refraction. Two photodetector options were considered: Burle MCP PMT and a novel photodetector—Hamamatsu MPPC. It is shown that FARICH with MPPC photodetector is able to separate at
3
σ
level pions and kaons up to 8
GeV/
c, muons and pions up to 1.5
GeV/
c
momentum.
The project of Forward RICH for SuperB factory based on focusing aerogel radiator is presented.
It is demonstrated that using a FARICH detector for the momentum measurement the momentum precision can be significantly improved.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
48.
Synthesis of aerogel tiles with high light scattering length Danilyuk, A.F.; Kravchenko, E.A.; Okunev, A.G. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
08/1999, Volume:
433, Issue:
1
Journal Article
Peer reviewed
The possibility of aerogel tiles production for RICH detectors is described. Monolithic blocks of silica aerogel were synthesized by two-step sol–gel processing of tetraethoxysilane Si(OEt)
4
...followed by high temperature supercritical drying with organic solvent. The important characteristic of aerogel is the light scattering length. In the wide range of refraction indexes the light scattering length exceeds 4
cm at 400
nm.
Full text
Available for:
IJS, IMTLJ, KILJ, KISLJ, NUK, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
The paper is devoted to the development of Cherenkov counters based on the Aerogel, wavelength SHIfters and PHotomultiplier tubes (ASHIPH) for the SND detector at VEPP-2000. The ASHIPH counter system ...for the SND detector is designed. The counters will separate π and K mesons in the momentum range from 300 to
900
MeV/c
. Optical properties of aerogel samples with refraction index 1.13 are measured and results are presented. As photodetectors, the microchannel plate photomultipliers with multialkali photocathodes are used. Monte Carlo simulation of the ASHIPH counter predicts more than 7 photoelectrons for a relativistic particle.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
50.
Aerogel as Cherenkov radiator for RICH detectors Bellunato, T.; Braem, A.; Buzykaev, A.R. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
04/2003, Volume:
502, Issue:
1
Journal Article
Peer reviewed
We present here the results obtained using silica aerogel as Cherenkov radiator for the separation and identification of particles in the momentum range from 6 to 10GeV/c. Photoelectron yield and ...Cherenkov ring resolution were studied under different experimental conditions and compared to the simulation.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK