Cancer-therapy related cardiotoxicity (CTRCT) is a significant and frequent complication of monoclonal antibody directed therapy, especially Trastuzumab, for human epidermal growth factor receptor 2 ...(HER2) overexpressing breast cancers. Reliable, clinically available molecular predictive markers of CTRCT have not yet been developed. Identifying specific genetic variants and their molecular markers, which make the host susceptible to this complication is key to personalised risk stratification. A systematic review was conducted until April 2021, using the Medline, Embase databases and Google Scholar, to identify studies genetic and RNA-related markers associated with CTRCT in HER2 positive breast cancer patients. So far, researchers have mainly focused on HER2 related polymorphisms, revealing codons 655 and 1170 variants as the most likely SNPs associated with cardiotoxicity, despite some contradictory results. More recently, new potential genetic markers unrelated to the HER2 gene, and linked to known cardiomyopathy genes or to genes regulating cardiomyocytes apoptosis and metabolism, have been detected. Moreover, microRNAs are gaining increasing recognition as additional potential molecular markers in the cardio-oncology field, supported by encouraging preliminary data about their relationship with cardiotoxicity in breast cancers. In this review, we sought to synthesize evidence for genetic variants and RNA-related molecular markers associated with cardiotoxicity in HER2-positive breast cancer.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Acute right-sided heart failure (RHF) is a complex clinical syndrome, with a wide range of clinical presentations, associated with increased mortality and morbidity, but about which there is a ...scarcity of evidence-based literature. A temporary right-ventricular assist device (t-RVAD) is a potential treatment option for selected patients with severe right-ventricular dysfunction as a bridge-to-recovery or as a permanent solution. We sought to conduct a systematic review to determine the safety and efficacy of t-RVAD implantation. Thirty-one studies met the inclusion criteria, from which data were extracted. Successful t-RVAD weaning ranged between 23% and 100%. Moreover, 30-day survival post-temporary RAVD implantation ranged from 46% to 100%. Bleeding, acute kidney injury, stroke, and device malfunction were the most commonly reported complications. Notwithstanding this, t-RVAD is a lifesaving option for patients with severe RHF, but the evidence stems from small non-randomized heterogeneous studies utilizing a variety of devices. Both the etiology of RHF and time of intervention might play a major role in determining the t-RVAD outcome. Standardized endpoints definitions, design and methodology for t-RVAD trials is needed. Furthermore, efforts should continue in improving the technology as well as improving the timely provision of a t-RVAD.
Left ventricular assist device (LVAD) therapy has been instrumental in saving lives of patients with end-stage heart failure (HF). Recent generation devices have short-to-mid-term survival rates ...close to heart transplantation. Unfortunately, up to 1 in 4 patients develop a life-threatening right-sided HF (RHF) early post LVAD implantation, with high morbidity and mortality rate, necessitating prolonged ICU stay, prolonged inotropic support, and implantation of a right-ventricular assist device. Pre-operative optimization of HF therapy could help in prevention, and/or mitigation of RHF. Levosimendan (LEVO) is a non-conventional inotropic agent that works by amplifying calcium sensitivity of troponin C in cardiac myocytes, without increasing the intra-cellular calcium or exacerbating ischemia. LEVO acts as an inodilator, which reduces the cardiac pre-, and after-load. LEVO administration is associated with hemodynamic improvements. Despite decades long of the use of LVAD and more than two decades of the use of LEVO for HF, the literature on LEVO use in LVAD is very limited. In this paper, we sought to conduct a systematic review to synthesize evidence related to the use of LEVO for the mitigation and/or prevention of RHF in patients undergoing LVAD implantation.
The new-generation ACURATE neo2 system was commercially released in September 2020. In this study, we sought to compare the aortic regurgitation (AR) severity of the ACURATE neo2 versus the ACURATE ...neo transcatheter heart valve, using quantitative videodensitometric angiography (qAR). This is a retrospective, Corelab analysis of final post-transcatheter aortic valve implantation (TAVI) aortograms of patients treated with the ACURATE neo2 and ACURATE neo systems. The ACURATE neo2 cohort comprised consecutive patients treated between September 2020 and January 2021 at two centers. The ACURATE neo cohort included consecutive patients treated before September 2020. Our primary objective was to compare AR severity on qAR following TAVI with ACURATE neo2 and ACURATE neo. Out of 401 aortograms, 228 (56.9%) were analyzable, with 120 in the ACURATE neo2 cohort, and 108 in the ACURATE neo cohort. The mean AR fraction was 4.4 ± 4.8% in the neo2 cohort, and 9.9 ± 8.2% in the neo cohort (p < 0.001). Furthermore, moderate or severe AR (qAR > 17%) was detected in 2 aortograms (1.7%) in the neo2 cohort and 15 aortograms (13.9%) in the neo cohort (p < 0.001). Quantitative aortography shows a lower rate of moderate or severe paravalvular AR in what is the first European experience of the new-generation, self-expanding ACURATE neo2 when compared to the first-generation ACURATE neo. Moreover, aortographic data need to be correlated and compared to Core Laboratory-adjudicated 30-day echocardiographic data.
Coronary artery calcium (CAC) scoring with computed tomography (CT) is an established tool for quantifying calcified atherosclerotic plaque burden. Despite the widespread use of novel image ...reconstruction techniques in CT, the effect of iterative model reconstruction on CAC score remains unclear. We sought to assess the impact of iterative model based reconstruction (IMR) on coronary artery calcium quantification as compared to the standard filtered back projection (FBP) algorithm and hybrid iterative reconstruction (HIR). In addition, we aimed to simulate the impact of iterative reconstruction techniques on calcium scoring based risk stratification of a larger asymptomatic population. We studied 63 individuals who underwent CAC scoring. Images were reconstructed with FBP, HIR and IMR and CAC scores were measured. We estimated the cardiovascular risk reclassification rate of IMR versus HIR and FBP in a larger asymptomatic population (n = 504). The median CAC scores were 147.7 (IQR 9.6–582.9), 107.0 (IQR 5.9–526.6) and 115.1 (IQR 9.3–508.3) for FBP, HIR and IMR, respectively. The HIR and IMR resulted in lower CAC scores as compared to FBP (both
p
< 0.001), however there was no difference between HIR and IMR (
p
= 0.855). The CAC score decreased by 7.2 % in HIR and 7.3 % in IMR as compared to FBP, resulting in a risk reclassification rate of 2.4 % for both HIR and IMR. The utilization of IMR for CAC scoring reduces the measured calcium quantity. However, the CAC score based risk stratification demonstrated modest reclassification in IMR and HIR versus FBP.
Full text
Available for:
EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
This paper looks to validate the risk score from the Heart Failure Association of the European Society of Cardiology and the International Cardio-Oncology Society (HFA-ICOS) for predicting potential ...cardiotoxicity from anticancer therapy for patients positive for human epidermal growth factor receptor 2.
A total of 507 patients with at least five years since index diagnosis of breast cancer were retrospectively divided according to the HFA-ICOS risk proforma. According to level of risk, these groups were assessed for rates of cardiotoxicity via mixed-effect Bayesian logistic regression model.
A follow-up of five years observed cardiotoxicity of 3.3% (
= 3) in the low-risk, 3.3% (
= 10) in the medium-risk, 4.4% (
= 6) in the high-risk, and 38% (
= 6) in the very-high-risk groups respectively. For cardiac events related to treatment, the risk was significantly higher for the very-high-risk category of HFA-ICOS compared to other categories (Beta = 3.1, 95% CrI: 1.5, 4.8). For overall cardiotoxicity related to treatment, the area under the curve was 0.643 (CI 95%: 0.51, 0.76), with 26.1% (95% CI: 8%, 44%) sensitivity and 97.9% (95% CI: 96%, 99%) specificity.
The HFA-ICOS risk score has moderate power in predicting cancer therapy-related cardiotoxicity in HER2-positive breast cancer patients.
Bicuspid aortic valve (BAV) is the most common valvular congenital anomaly and is apparent in nearly 50% of candidates for AV replacement. While transcatheter aortic valve implantation (TAVI) is a ...recommended treatment for patients with symptomatic severe aortic stenosis (AS) at all surgical risk levels, experience with TAVI in severe bicuspid AS is limited. TAVI in BAV is still a challenge due to its association with multiple and complex anatomical considerations. A retrospective study has been conducted to investigate TAVI's procedural and 30-day outcomes using the Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd. Vapi, Gujarat, India) in patients with severe bicuspid AS. Data were collected on 68 patients with severe bicuspid AS who underwent TAVI with the Myval THV. Baseline characteristics, procedural, 30-day echocardiographic and clinical outcomes were collected. The mean age and STS PROM score were 72.6 ± 9.4 and 3.54 ± 2.1. Procedures were performed via the transfemoral route in 98.5%. Major vascular complications (1.5%) and life-threatening bleeding (1.5%) occurred infrequently. No patient had coronary obstruction, second valve implantation or conversion to surgery. On 30-day echocardiography, the mean transvalvular gradient and effective orifice area were 9.8 ± 4.5 mmHg and 1.8 ± 0.4 cm
, respectively. None/trace aortic regurgitation occurred in 76.5%, mild AR in 20.5% and moderate AR in 3%. The permanent pacemaker implantation rate was 8.5% and 30-day all-cause death occurred in 3.0% of cases. TAVI with the Myval THV in selected BAV anatomy is associated with favorable short-term hemodynamic and clinical outcomes.
Bicuspid aortic valve (BAV) affects approximately 1.5% of the general population and is seen in nearly 50% of candidates for aortic valve replacement (AVR). Despite increasingly utilised ...transcatheter aortic valve implantation (TAVI) in aortic stenosis (AS) patients, its use among patients with severe bicuspid AS is limited as BAV is a heterogeneous disease associated with multiple and complex anatomical challenges.
To investigate the one-year outcomes of TAVI using the balloon-expandable Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd., Vapi, India) in patients with severe bicuspid AS.
We collected data from consecutive patients with bicuspid AS who underwent TAVI with the Myval THV and had at least one-year follow-up. Baseline characteristics, procedural, and 30-day echocardiographic and clinical outcomes were collected. Sixty-two patients were included in the study. The median age was 72 66.3, 77.0 years, 45 (72.6%) were males, and the mean STS PROM score was 3.2 ± 2.2%. All TAVI procedures were performed via the transfemoral route. The median follow-up duration was 13.5 12.2, 18.3 months; all-cause mortality was reported in 7 (11.3%) patients and cardiovascular hospitalisation in 6 (10.6%) patients. All-stroke was reported in 2 (3.2%), permanent pacemaker implantation 5 (8.3%), and myocardial infarction 1 (1.6%) patients. The echocardiographic assessment revealed a mean pressure gradient of 10 8, 16.5 mmHg, effective orifice area 1.7 1.4, 1.9 cm
, moderate AR in 1 (2%), mild AR in 14 (27%), and none/trace AR in 37 (71%). In total, 1 patient was diagnosed with valve thrombosis (2.1%), Stage II (moderate) haemodynamic deterioration was seen in 3 (6.4%), and stage III (severe) haemodynamic deterioration in 1 (2.1%) patient.
TAVI with the Myval THV in selected BAV anatomy is associated with favourable one-year hemodynamic and clinical outcomes.
Transcatheter aortic valve replacement (TAVR) is a recommended intervention for selected population with severe aortic stenosis (AS). Bicuspid aortic valve (BAV) anatomy has been categorized as an ...unfavorable anatomy for TAVR due to multiple considerations as exclusion from randomized trials in addition to the challenging and unpredictable anatomy. The anatomical constraints of BAV include the large anatomy of the annulus, sinus of Valsalva, and aorta (aortopathy), in addition to significant calcifications of the device landing zone. Most commercial transcatheter heart valves (THV) have upper dimension limits of the annulus and area in which the device can be implanted safely without significant oversizing. Myval-XL THVs (Meril Life Sciences Pvt. Ltd., India) are balloon-expandable valves (BEV) that have been developed with two new sizes, 30.5 and 32 mm, aiming to treat patients with large annulus dimensions and that exceed the upper limit of an ordinary device's sizing matrix. This case series report describes TAVR using the XL-Myval 32 mm THV in three European patients with symptomatic severe bicuspid aortic stenosis with significant calcifications and large annular dimensions exceeding the limits of the other THVs.
(1) Background: Conduction disturbance requiring a new permanent pacemaker (PPM) after transcatheter aortic valve implantation (TAVI) has traditionally been a common complication. New implantation ...techniques with self-expanding platforms have reportedly reduced the incidence of PPM. We sought to investigate the predictors of PPM at 30 days after TAVI using Evolut R/PRO/PRO+; (2) Methods: Consecutive patients who underwent TAVI with the Evolut platform between October 2019 and August 2022 at University Hospital Galway, Ireland, were included. Patients who had a prior PPM (
= 10), valve-in-valve procedures (
= 8) or received >1 valve during the index procedure (
= 3) were excluded. Baseline clinical, electrocardiographic (ECG), echocardiographic and multislice computed tomography (MSCT) parameters were analyzed. Pre-TAVI MSCT analysis included membranous septum (MS) length, a semi-quantitative calcification analysis of the aortic valve leaflets, left ventricular outflow tract, and mitral annulus. Furthermore, the implantation depth (ID) was measured from the final aortography. Multivariate binary logistic analysis and receiver operating characteristic (ROC) curve analysis were used to identify independent predictors and the optimal MS and ID cutoff values to predict new PPM requirements, respectively; (3) Results: A total of 129 TAVI patients were included (age = 81.3 ± 5.3 years; 36% female; median EuroSCORE II 3.2 2.0, 5.4). Fifteen patients (11.6%) required PPM after 30 days. The patients requiring new PPM at 30 days were more likely to have a lower European System for Cardiac Operative Risk Evaluation II, increased prevalence of right bundle branch block (RBBB) at baseline ECG, have a higher mitral annular calcification severity and have a shorter MS on preprocedural MSCT analysis, and have a ID, as shown on the final aortogram. From the multivariate analysis, pre-TAVI RBBB, MS length, and ID were shown to be predictors of new PPM. An MS length of <2.85 mm (AUC = 0.85, 95%CI: (0.77, 0.93)) and ID of >3.99 mm (area under the curve (AUC) = 0.79, (95% confidence interval (CI): (0.68, 0.90)) were found to be the optimal cut-offs for predicting new PPM requirements; (4) Conclusions: Membranous septum length and implantation depth were found to be independent predictors of new PPM post-TAVI with the Evolut platform. Patient-specific implantation depth could be used to mitigate the requirement for new PPM.