Recent theoretical and experimental studies highlight the possibility of new fundamental particle physics beyond the Standard Model that can be probed by sub-eV energy experiments. The OSQAR photon ...regeneration experiment looks for “Light Shining through a Wall” from the quantum oscillation of optical photons into “Weakly Interacting Sub-eV Particles”, like axion or axion-like particles (ALPs), in a 9 T transverse magnetic field over the unprecedented length of
2
×
14.3
m. No excess of events has been detected over the background. The di-photon couplings of possible new light scalar and pseudo-scalar particles can be constrained in the massless limit to be less than
8.0
×
10
-
8
GeV
-
1
. These results are very close to the most stringent laboratory constraints obtained for the coupling of ALPs to two photons. Plans for further improving the sensitivity of the OSQAR experiment are presented.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Physics beyond the Standard Model predicts the possible existence of new particles that can be searched at the low energy frontier in the sub-eV range. The OSQAR photon regeneration experiment looks ...for "Light Shining through a Wall" from the quantum oscillation of optical photons into "Weakly Interacting Sub-eV Particles", such as axion or Axion-Like Particles (ALPs), in a 9 T transverse magnetic field over the unprecedented length of 2 × 14.3 m. In 2014, this experiment has been run with an outstanding sensitivity, using an 18.5 W continuous wave laser emitting in the green at the single wavelength of 532 nm. No regenerated photons have been detected after the wall, pushing the limits for the existence of axions and ALPs down to an unprecedented level for such a type of laboratory experiment. The di-photon couplings of possible pseudoscalar and scalar ALPs can be constrained in the nearly massless limit to be less than 3.5·10 −8 GeV −1 and 3.2·10 −8 GeV −1 , respectively, at 95% Confidence Level.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
COMPASS RICH-1 is a large size gaseous Imaging Cherenkov Detector providing hadron identification in the range from 3 to 55 GeV/c, in the wide acceptance spectrometer of the COMPASS Experiment at ...CERN SPS. It uses a 3m long C sub(4)F sub(10) radiator, a 21 m super(2) large VUV mirror surface and two kinds of photon detectors: MAPMTs and MWPCs with CsI photocathodes, covering a total of 5.5 m super(2). It is in operation since 2002 and its performance increased thanks to progressive optimization and to a major upgrade of its photon detection system, implemented in 2006; a new upgrade is foreseen for 2016, with the use of MPGD-based photon detectors. The main characteristics of COMPASS RICH-1 components are described and the most critical aspects related to the C sub(4)F sub(10) radiator gas system, to the mirrors and their alignment, as well as the performance of the photon detectors are presented and discussed. The response of the MWPCs and the observed evolution of the effective quantum efficiency of the CsI photocathodes is analyzed. The properties and performance of the MAPMTs with individual fused lens telescopes are presented together with the readout characteristics. The PID performance of COMPASS RICH-1 is discussed and the future upgrade program is mentioned.
The THicK GEM (THGEM) electron multipliers are derived from the GEM design, by scaling the geometrical parameters and changing the production technology. Small-size (a few cm super(2)) detectors ...exhibit superb performance, while larger ones exhibit gain response and uniformity limitations. We have studied with a systematic approach several aspects concerning the material (type and thickness of the fibreglass plates) and the production procedure, in particular the cleaning and polishing stages. The net result is the production of large THGEM multipliers reproducing the performance of the small ones. We report in detail about the studies and the results.
In fundamental research, gas detectors of single photons are a must in the field of Cherenkov imaging techniques (RICH counters) for particle identification in large momentum ranges and with wide ...coverage of the phase space domain. These counters, already extensively used, are foreseen in the setups of future experiments in a large variety of fields in nuclear and particle physics. The quest of novel gaseous photon detector is dictated by the fact that the present generation of detectors has unique characteristics concerning operation in magnetic field, low material budget and cost, but it suffers of severe limitations in effective efficiency, rates, life time and stability, discouraging their use in high precision and high rate experiments. We are developing large size THick GEM (THGEM)-based detector of single photons. The R&D program includes the complete characterization of the THGEM electron multipliers, the study of the aspects related to the detection of single photons and the engineering towards large size detector prototype. Our most recent achievements include: dedicated studies concerning the ion back-flow to the photo-cathode; relevant progress in the engineering aspects, in particular related to the production of large-size THGEMs, where the strict correlation between the local gain-value and the local thickness-value has been demonstrated the operation of a 300 mm x 300 mm super(2) active area detector at the CERN PS T10 test beam; the introduction of a new hybrid detector architecture offering promising indication, which is formed by a THGEMlayer which acts as CsI support and pre-amplification device followed by a MICROMEGAS multiplication stage. The general status of the R&D program and the recent progress are reported
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of ...the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5m2 have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. They are the first application in an experiment of MPGD-based single photon detectors. All aspects of the upgrade are presented, including engineering, mass production, quality assessment and performance.
Perspectives for further developments in the field of gaseous single photon detectors are also presented.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Cholera was introduced into Haiti in 2010. Since then, more than 820 000 cases and nearly 10 000 deaths have been reported. Oral cholera vaccine (OCV) is safe and effective, but has not been seen as ...a primary tool for cholera elimination due to a limited period of protection and constrained supplies. Regionally, epidemic cholera is contained to the island of Hispaniola, and the lowest numbers of cases since the epidemic began were reported in 2019. Hence, Haiti may represent a unique opportunity to eliminate cholera with OCV.
In this modelling study, we assessed the probability of elimination, time to elimination, and percentage of cases averted with OCV campaign scenarios in Haiti through simulations from four modelling teams. For a 10-year period from January 19, 2019, to Jan 13, 2029, we compared a no vaccination scenario with five OCV campaign scenarios that differed in geographical scope, coverage, and rollout duration. Teams used weekly department-level reports of suspected cholera cases from the Haiti Ministry of Public Health and Population to calibrate the models and used common vaccine-related assumptions, but other model features were determined independently.
Among campaigns with the same vaccination coverage (70% fully vaccinated), the median probability of elimination after 5 years was 0-18% for no vaccination, 0-33% for 2-year campaigns focused in the two departments with the highest historical incidence, 0-72% for three-department campaigns, and 35-100% for nationwide campaigns. Two-department campaigns averted a median of 12-58% of infections, three-department campaigns averted 29-80% of infections, and national campaigns averted 58-95% of infections. Extending the national campaign to a 5-year rollout (compared to a 2-year rollout), reduced the probability of elimination to 0-95% and the proportion of cases averted to 37-86%.
Models suggest that the probability of achieving zero transmission of Vibrio cholerae in Haiti with current methods of control is low, and that bolder action is needed to promote elimination of cholera from the region. Large-scale cholera vaccination campaigns in Haiti would offer the opportunity to synchronise nationwide immunity, providing near-term population protection while improvements to water and sanitation promote long-term cholera elimination.
Bill & Melinda Gates Foundation, Global Good Fund, Institute for Disease Modeling, Swiss National Science Foundation, and US National Institutes of Health.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
This study evaluates the prognostic performance of a 15 gene expression profiling (GEP) assay that assigns primary posterior uveal melanomas to prognostic subgroups: class 1 (low metastatic risk) and ...class 2 (high metastatic risk).
Prospective, multicenter study.
A total of 459 patients with posterior uveal melanoma were enrolled from 12 independent centers.
Tumors were classified by GEP as class 1 or class 2. The first 260 samples were also analyzed for chromosome 3 status using a single nucleotide polymorphism assay. Net reclassification improvement analysis was performed to compare the prognostic accuracy of GEP with the 7th edition clinical Tumor-Node-Metastasis (TNM) classification and chromosome 3 status.
Patients were managed for their primary tumor and monitored for metastasis.
The GEP assay successfully classified 446 of 459 cases (97.2%). The GEP was class 1 in 276 cases (61.9%) and class 2 in 170 cases (38.1%). Median follow-up was 17.4 months (mean, 18.0 months). Metastasis was detected in 3 class 1 cases (1.1%) and 44 class 2 cases (25.9%) (log-rank test, P<10(-14)). Although there was an association between GEP class 2 and monosomy 3 (Fisher exact test, P<0.0001), 54 of 260 tumors (20.8%) were discordant for GEP and chromosome 3 status, among which GEP demonstrated superior prognostic accuracy (log-rank test, P = 0.0001). By using multivariate Cox modeling, GEP class had a stronger independent association with metastasis than any other prognostic factor (P<0.0001). Chromosome 3 status did not contribute additional prognostic information that was independent of GEP (P = 0.2). At 3 years follow-up, the net reclassification improvement of GEP over TNM classification was 0.43 (P = 0.001) and 0.38 (P = 0.004) over chromosome 3 status.
The GEP assay had a high technical success rate and was the most accurate prognostic marker among all of the factors analyzed. The GEP provided a highly significant improvement in prognostic accuracy over clinical TNM classification and chromosome 3 status. Chromosome 3 status did not provide prognostic information that was independent of GEP.