The purpose of this manuscript is to report our experience in the 2021 SIIM Virtual Hackathon, where we developed a proof-of-concept of a radiology training module with elements of gamification. In ...the 50 h allotted in the hackathon, we proposed an idea, connected with colleagues from five different countries, and completed an operational proof-of-concept, which was demonstrated live at the hackathon showcase, competing with eight other teams. Our prototype involved participants annotating publicly available chest radiographs of patients with tuberculosis. We showed how we could give experience points to trainees based on annotation precision compared to ground truth radiologists’ annotation, ranked in a live leaderboard. We believe that gamification elements could provide an engaging solution for radiology education. Our project was awarded first place out of eight participating hackathon teams.
Full text
Available for:
NUK, SBMB, SBNM, UL, UM, UPUK, VSZLJ
Abstract Background Chest CT scans are frequently performed in radiology departments but have not previously contained detailed depiction of cardiac structures. Objectives To evaluate myocardial and ...coronary visualization on high-pitch non-gated CT of the chest using 3rd generation dual-source computed tomography (CT). Methods Cardiac anatomy of patients who had 3rd generation, non-gated high pitch contrast enhanced chest CT and who also had prior conventional (low pitch) chest CT as part of a chest abdomen pelvis exam was evaluated. Cardiac image features were scored by reviewers blinded to diagnosis and pitch. Paired analysis was performed. Results 3862 coronary segments and 2220 cardiac structures were evaluated by two readers in 222 CT scans. Most patients (97.2%) had chest CT for oncologic evaluation. The median pitch was 2.34 (IQR 2.05, 2.65) in high pitch and 0.8 (IQR 0.8, 0.8) in low pitch scans (p < 0.001). High pitch CT showed higher image visualization scores for all cardiovascular structures compared with conventional pitch scans (p < 0.0001). Coronary arteries were visualized in 9 coronary segments per exam in high pitch scans versus 2 segments for conventional pitch (p < 0.0001). Radiation exposure was lower in the high pitch group compared with the conventional pitch group (median CTDIvol 10.83 vs. 12.36 mGy and DLP 790 vs. 827 mGycm respectively, p < 0.01 for both) with comparable image noise (p = 0.43). Conclusion Myocardial structure and coronary arteries are frequently visualized on non-gated 3rd generation chest CT. These results raise the question of whether the heart and coronary arteries should be routinely interpreted on routine chest CT that is otherwise obtained for non-cardiac indications.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK, ZRSKP
The purpose of this study was to evaluate the success, consistency, and efficiency of a semiautomated lesion management application within a PACS in the analysis of metastatic lesions in serial CT ...examinations of cancer patients.
Two observers using baseline and follow-up CT data independently reviewed 93 target lesions (17 lung, five liver, 71 lymph node) in 50 patients with either metastatic bladder or prostate cancer. The observers measured the longest axis (or short axis for lymph nodes) of each lesion and made Response Evaluation Criteria in Solid Tumors (RECIST) determinations using manual and lesion management application methods. The times required for examination review, RECIST calculations, and data input were recorded. The Wilcoxon signed rank test was used to assess time differences, and Bland-Altman analysis was used to assess interobserver agreement within the manual and lesion management application methods. Percentage success rates were also reported.
With the lesion management application, most lung and liver lesions were semiautomatically segmented. Comparison of the lesion management application and manual methods for all lesions showed a median time saving of 45% for observer 1 (p<0.05) and 28% for observer 2 (p=0.05) on follow-up scans versus 28% for observer 1 (p<0.05) and 9% for observer 2 (p=0.087) on baseline scans. Variability of measurements showed mean percentage change differences of only 8.9% for the lesion management application versus 26.4% for manual measurements.
With the lesion management application method, most lung and liver lesions were successfully segmented semiautomatically; the results were more consistent between observers; and assessment of tumor size was faster than with the manual method.
Our current study was undertaken in order to compare CT exposures during various dose-reduction initiatives at the National Institutes of Health Clinical center, to show trends in exposure reduction ...over a 5-y period, and to provide benchmarks that other facilities may use. Using an in-house extraction tool (Radiation Exposure Extraction Engine), we derived CT exposure data from Digital Imaging and Communications in Medicine (DICOM) headers over 5 y. We present parameters used and compare most common exams between 2010 and 2015. During a period of exposure-reduction initiatives, data of 79 396 exams from nine CT scanners on 87 scan protocols were analyzed. Adult chest exposures were reduced 53% and chest, abdomen and pelvis exams were reduced 43% (p < 0.001). Only extremity exams did not show significantly reduced exposure. Collecting data over several years allowed us to confirm and compare several initiatives. We demonstrated significant exposure reductions during continued reduction efforts on common exams. Our results may provide benchmarks for similar centers.
Despite technological advances in the analysis of digital images for medical consultations, many health information systems lack the ability to correlate textual descriptions of image findings linked ...to the actual images. Images and reports often reside in separate silos in the medical record throughout the process of image viewing, report authoring, and report consumption. Forward-thinking centers and early adopters have created interactive reports with multimedia elements and embedded hyperlinks in reports that connect the narrative text with the related source images and measurements. Most of these solutions rely on proprietary single-vendor systems for viewing and reporting in the absence of any encompassing industry standards to facilitate interoperability with the electronic health record (EHR) and other systems. International standards have enabled the digitization of image acquisition, storage, viewing, and structured reporting. These provide the foundation to discuss enhanced reporting. Lessons learned in the digital transformation of radiology and pathology can serve as a basis for interactive multimedia reporting (IMR) across image-centric medical specialties. This paper describes the standard-based infrastructure and communications to fulfill recently defined clinical requirements through a consensus from an international workgroup of multidisciplinary medical specialists, informaticists, and industry participants. These efforts have led toward the development of an Integrating the Healthcare Enterprise (IHE) profile that will serve as a foundation for interoperable interactive multimedia reporting.
Full text
Available for:
NUK, SBMB, SBNM, UL, UM, UPUK, VSZLJ
Our goal was to evaluate a new software capability that integrates registration, segmentation and tumor measurement across serial exams within a picture archiving communication system (PACS) to ...expedite tumor measurement.
Patients treated under institutional review board-approved protocols for metastatic melanoma were retrospectively reviewed. Of the 19 included patients, five were male, the median age was 43.2, and all received treatment using an adoptive cell therapy. Seventy-one lung, liver, and subcutaneous tumors were manually measured using RECIST (Response Evaluation Criteria In Solid Tumors) criteria before therapy (baseline computed tomography CT) and within 3 months after therapy (follow-up CT). We performed semiautomated registration, segmentation, and RECIST measurements at both time points within PACS (Carestream Health, Rochester, NY). We compared manual and software-generated RECIST measurements using Bland-Altman plots.
The median manually measured RECIST diameter for all baseline tumors was 2.1 (1.0-6.2) cm. The refined registration function identified 70/71 (98.6%) tumors on the follow-up CT. On the baseline CT, all 21 liver, 27/32 (84%) lung, and 10/18 (55%) subcutaneous tumors completed segmentation. On the follow-up CT, 19/21 (90%) liver, 21/27 (78%) lung, and 8/10 (80%) subcutaneous tumors completed segmentation. The Bland-Altman plot demonstrated a 95% confidence interval of ±0.7 cm when comparing the software-generated and manual RECIST measurements.
The PACS software performed semiautomated baseline tumor measurements and fully automated follow-up tumor measurements in a majority of lung, liver, and subcutaneous tumors. In our patients, semiautomated metastatic tumor measurement did not obviate the need for physician oversight due to disease and treatment-related factors.
The Response Evaluation Criteria in Solid Tumors (RECIST) are the current standard for evaluating disease progression or therapy response in patients with solid tumors. RECIST 1.1 calls for axial, ...longest-diameter (or perpendicular short axis of lymph nodes) measurements of a maximum of five tumors, which limits clinicians' ability to adequately measure disease burden, especially in patients with irregularly shaped tumors. This is especially problematic in chordoma, a disease for which RECIST does not always adequately capture disease burden because chordoma tumors are typically irregularly shaped and slow-growing. Furthermore, primary chordoma tumors tend to be adjacent to vital structures in the skull or sacrum that, when compressed, lead to significant clinical consequences.
Volumetric segmentation is a newer technology that allows tumor burden to be measured in three dimensions on either MR or CT. Here, we compared the ability of RECIST measurements and tumor volumes to predict clinical outcomes in a cohort of 21 chordoma patients receiving immunotherapy.
There was a significant difference in radiologic time to progression Kaplan-Meier curves between clinical outcome groups using volumetric segmentation (P = 0.012) but not RECIST (P = 0.38). In several cases, changes in volume were earlier and more sensitive reflections of clinical status.
RECIST is a useful evaluation method when obvious changes are occurring in patients with chordoma. However, in many cases, RECIST does not detect small changes, and volumetric assessment was capable of detecting changes and predicting clinical outcome earlier than RECIST. Although this study was small and retrospective, we believe our results warrant further research in this area.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Chest Imaging Folio, Les R
2011, 20111103, 2012-01-28
eBook
The chest X-ray (CXR) or chest radiograph remains the most commonly ordered imaging study in medicine, yet paradoxically is often the most complex to learn, recall, and master effective and accurate ...interpretation. The chest radiograph includes all thoracic anatomy and provides a high yield, given the low cost and single source. This guide presents a structured lexicon for use by readers to reproducibly describe radiographic abnormalities of the chest detected on plain film CXRs. The lexicon is designed to provide readers with clinically significant differentiation of abnormalities detected. The content is structured to relate specific combinations of distinct radiographic findings to classes/groupings of pathological etiologies of those findings. Recognizing the individual findings and identifying their combination or lack of combination with other individual findings allows readers to create effective differential diagnoses that can then be further evaluated using other imaging procedures and/or non-radiographic clinical information. The book includes hundreds of images, including radiographs, CTs, graphics, and analogous models to help teach otherwise complex processes and radiographic principles. Col. Les Folio, a retired air force radiologist and flight surgeon with over twenty years of service, presents a comprehensive introduction to diagnostic imaging technology.
Full text
Available for:
FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NUK, OBVAL, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
Patients with autoimmune lymphoproliferative syndrome (ALPS), a disorder of impaired lymphocyte apoptosis, often undergo radiographic chest imaging to evaluate the presence and progression of ...lymphadenopathy. These images often lead to parenchymal and interstitial lung findings of unclear clinical significance.
To characterize the pulmonary findings associated with ALPS and to determine if lung abnormalities present on computed tomographic (CT) imaging of the chest correlate with infection or functional status.
Patients with lung abnormalities observed on chest CT scans were retrospectively identified from the largest known ALPS cohort. Lung computed tomography findings were characterized and correlated with medical records, bronchoalveolar lavage, biopsy, and lung function.
CT images of the chest were available for 234 (92%) of 255 of the patients with ALPS. Among patients with a chest CT scan, 18 (8%) had lung abnormalities on at least one CT scan. Fourteen (78%) of those 18 were classified as having ALPS with undetermined genetic defect. Most patients (n = 16 89%) with lung lesions were asymptomatic. However, two (11%) of them had associated dyspnea and/or desaturation on room air. Immunosuppressive treatment was administered for lung disease in nine (50%) cases, and all were followed for clinical outcomes.
Patients with ALPS can develop chest radiographic findings with protean manifestations that may mimic pulmonary infection. Management of patients with ALPS with incidental lung lesions identified by CT imaging should be guided by clinical correlation. Symptomatic patients may benefit from chest CT imaging and lesion biopsy to exclude infection and guide administration of immunosuppressive therapy.