Corneal hysteresis (CH) measured with Ocular Response Analyzer (Reichert: ORA) has been reported to be closely related to the glaucomatous visual field (VF) progression. The air pulse applied to an ...eye not only induces corneal deformation, but also whole eye motion (WEM), which may result in an inaccurate measurement of CH. Here we investigated the influence of air pulse-driven WEM measured with the Corivs ST (CST
, OCULUS) on the relationship between CH and VF progression in primary open angle-glaucoma patients. Using the CST parameters of the maximal WEM displacement (WEM-d) and the time to reach that displacement (WEM-t), the eyes were classified into subgroups (WEM-d low- and high-group, and WEM-t short- and long-group). For the whole population and all subgroups, the optimal linear mixed model to describe mean of total deviation (mTD) progression rate with eight reliable VFs was selected from all combinations of seven parameters including CH. As a result, optimal models for the mTD progression rate included CH in the whole population, the WEM-d low- group and the WEM-t short-group, but not in the WEM-d high-group and the WEM-t long-group. Our findings indicated association between CH and glaucomatous progression can be weakened because of large WEM.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
The aim of the study was to investigate the usefulness of processing visual field (VF) using a variational autoencoder (VAE). The training data consisted of 82,433 VFs from 16,836 eyes. Testing ...dataset 1 consisted of test-retest VFs from 104 eyes with open angle glaucoma. Testing dataset 2 was series of 10 VFs from 638 eyes with open angle glaucoma. A VAE model to reconstruct VF was developed using the training dataset. VFs in the testing dataset 1 were then reconstructed using the trained VAE and the mean total deviation (mTD) was calculated (mTD
). In testing dataset 2, the mTD value of the tenth VF was predicted using shorter series of VFs. A similar calculation was carried out using a weighted linear regression where the weights were equal to the absolute difference between mTD and mTD
. In testing dataset 1, there was a significant relationship between the difference between mTD and mTD
from the first VF and the difference between mTD in the first and second VFs. In testing dataset 2, mean squared prediction errors with the weighted mTD trend analysis were significantly smaller than those form the unweighted mTD trend analysis.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
The aim of the current study is to identify possible new Ocular Response Analyzer (ORA) waveform parameters related to changes of retinal structure/deformation, as measured by the peripapillary ...retinal arteries angle (PRAA), using a generative deep learning method of variational autoencoder (VAE). Fifty-four eyes of 52 subjects were enrolled. The PRAA was calculated from fundus photographs and was used to train a VAE model. By analyzing the ORA waveform reconstructed (noise filtered) using VAE, a novel ORA waveform parameter (Monot1-2), was introduced, representing the change in monotonicity between the first and second applanation peak of the waveform. The variables mostly related to the PRAA were identified from a set of 41 variables including age, axial length (AL), keratometry, ORA corneal hysteresis, ORA corneal resistant factor, 35 well established ORA waveform parameters, and Monot1-2, using a model selection method based on the second-order bias-corrected Akaike information criterion. The optimal model for PRAA was the AL and six ORA waveform parameters, including Monot1-2. This optimal model was significantly better than the model without Monot1-2 (p = 0.0031, ANOVA). The current study suggested the value of a generative deep learning approach in discovering new useful parameters that may have clinical relevance.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
Introduction
The purpose of this study was to compare the surgical outcomes between ab interno trabeculotomy (LOT) and iStent inject W implantation (iStent) both combined with cataract surgery, ...matching the background factors including age, intraocular pressure (IOP), medication score, central corneal thickness (CCT), and axial length.
Methods
A total of 100 eyes from 75/79 patients with primary open-angle glaucoma were included in the LOT/iStent groups. The background factors were matched between the two groups using the propensity score.
Results
There were no significant differences in age, IOP, medication score, CCT, and axial length, preoperatively. The postoperative medication scores were 1.3 ± 1.2 and 1.2 ± 1.2 in the LOT and iStent groups. The postoperative IOPs were 12.8 ± 2.8 and 13.1 ± 2.4 mmHg in the LOT and iStent groups, respectively. The changes in the medication score were − 0.64 ± 1.4 and − 0.44 ± 1.6 in the LOT and iStent groups, respectively. The changes in the IOP were − 2.1 ± 3.3 and − 1.5 ± 3.0 mmHg in the LOT and iStent groups, respectively. These values were not significantly different between the two groups. The postoperative IOP and changes in the IOP were significantly associated with preoperative IOP and CCT. There was no significant difference in the occurrence of postoperative complications (hyphema, 11.0% and 6.0%, and transient ocular hypertension, 8.0% and 5.0%, in the LOT and iStent groups, respectively).
Conclusion
LOT and iStent have similar surgical outcomes with sufficient safety. Postoperative IOP was significantly associated with preoperative IOP and CCT in both groups.
Visual field (VF) data were retrospectively obtained from 491 eyes in 317 patients with open angle glaucoma who had undergone ten VF tests (Humphrey Field Analyzer, 24-2, SITA standard). First, mean ...of total deviation values (mTD) in the tenth VF was predicted using standard linear regression of the first five VFs (VF1-5) through to using all nine preceding VFs (VF1-9). Then an 'intraocular pressure (IOP)-integrated VF trend analysis' was carried out by simply using time multiplied by IOP as the independent term in the linear regression model. Prediction errors (absolute prediction error or root mean squared error: RMSE) for predicting mTD and also point wise TD values of the tenth VF were obtained from both approaches. The mTD absolute prediction errors associated with the IOP-integrated VF trend analysis were significantly smaller than those from the standard trend analysis when VF1-6 through to VF1-8 were used (p < 0.05). The point wise RMSEs from the IOP-integrated trend analysis were significantly smaller than those from the standard trend analysis when VF1-5 through to VF1-9 were used (p < 0.05). This was especially the case when IOP was measured more frequently. Thus a significantly more accurate prediction of VF progression is possible using a simple trend analysis that incorporates IOP measurements.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
The purpose of the study was to investigate whether the structure-function relationship in glaucomatous and normative eyes is improved by considering photoreceptor layer thickness. Humphrey 10-2 ...visual fields (VF) and optical coherence tomography were carried out in 615 eyes of 391 subjects, including 100 eyes of 53 healthy controls and 515 eyes of 338 glaucoma patients. The relationship between mean VF sensitivity and the thickness of the retinal nerve fiber layer (RNFL) and ganglion cell layer and inner plexiform layer (GCL + IPL) was analyzed using linear mixed models, by glaucoma status and degree of myopia. The structure-function relationship was also analyzed by supplementing the RNFL and GCL + IPL thickness with the thicknesses of: (i) the inner nuclear layer and outer plexiform layer (INL + OPL); (ii) the outer nuclear layer and inner segment of photoreceptor layer (ONL + ISL); (iii) the outer segment layer of photoreceptor and retinal pigment epithelium (OSL + RPE). The model included total thickness of RNFL, GCL + IPL and OSL + RPE was highly more optimal than the model that only included the total thickness of RNFL and GCL + IPL, in all subsets of eyes by glaucoma status and degree of myopia.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
To investigate the effects of ocular and systemic risk factors for glaucomatous progression in different sectors of the visual field (VF).
409 eyes from 268 patients with 10 reliable VFs from the ...Japanese Archive of Multicentral Databases in Glaucoma (JAMDIG) were investigated. VFs were divided into six sectors (mean total deviation (mTD)
, mTD
and mTD
, >20°, 10-20° and <10° in the superior hemifield, respectively; and mTD
, mTD
and mTD
, >20°, 10-20° and <10° in the inferior hemifield, respectively). The relationship between sectorial progression rate and eight variables (age, mTD at baseline VF, average intraocular pressure (IOP), SD of IOP, systemic hypertension, migraine, family history of glaucoma and smoking status) was investigated.
The mTD progression rate was -0.21 dB/year. Older age was related to progression of mTD
, mTD
, mTD
and mTD
. Mean IOP was not related to progression in any VF sector; however, a larger SD of IOP was related to progression of mTD
, mTD
, mTD
and mTD
. Smoking status was related to progression in all inferior VF sectors (mTD
, mTD
and mTD
).
Smoking status is related to glaucomatous VF progression in all sectors of the inferior hemifield.
We previously reported that a shallow circumpapillary retinal nerve fiber layer (cpRNFL) peak angle as measured by optical coherence tomography (OCT) suggests the temporal retina is stretched around ...the optic disc from the papillo-macular bundle (Yamashita T et al. Investigative Ophthalmol Vis Sci 2013). The purpose of the current study was to investigate the relationship between CorvisST tonometry (CST) corneal measurements, axial length (AL) and the change in OCT-measured cpRNFL peak angle, in young healthy subjects. OCT and CST measurements were carried out in 97 eyes of 97 young healthy volunteers. The relationship between cpRNFL peak angle and 12 CST parameters, adjusted for AL, was investigated using linear modelling. The mean ± standard deviation cpRNFL peak angle of the 97 healthy volunteers was 130.6 ± 25.4 (range: 77.8 to 207.0) degrees. The optimal linear model to explain cpRNFL peak angle (chosen from 2
different models) included three CST variables related to the speed and size of energy absorption (namely, A1 time, A1 length and A2 time), in addition to AL. In eyes with longer AL and shorter energy absorption in CST measurement, temporal retina is stretched around the optic disc from the papillo-macular bundle, as suggested by a shallow cpRNFL peak angle.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK