The cross section of the process e + e − → π + π − has been measured in the center-of-mass energy range from 0.32 to 1.2 GeV with the CMD-3 detector at the electron-positron collider VEPP-2000. The ...measurement is based on an integrated luminosity of about 88 pb − 1 , of which 62 pb − 1 represent a complete dataset collected by CMD-3 at center-of-mass energies below 1 GeV. In the dominant region near the ρ resonance a systematic uncertainty of 0.7% was achieved. The implications of the presented results for the evaluation of the hadronic contribution to the anomalous magnetic moment of the muon are discussed. Published by the American Physical Society 2024
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UL, UM
This paper describes a currently being developed procedure of the charged particle identification for CMD-3 detector, installed at the VEPP-2000 collider. The procedure is based on the application of ...the boosted decision trees classification method, and uses as input variables the specific energy losses of charged particles in the 14 layers of the liquid Xenon calorimeter. The performance of the procedure is demonstrated by an example of the extraction of events of e+e−→K+K−(γ) process in the center of mass energy range from 1.28 to 1.65 GeV.
•The multilayer ionization calorimeter provides multiple dE/dx measurements.•The multiple dE/dx measurements can be used for particle identification.•The set of dE/dx values can be used as input of the boosted decision trees classifier.•The BDT response characterizes the likely type of the particle.•The approach works efficiently for kaon identification at momenta less than 1 GeV/c.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
Vibrations of a thin-walled cantilever rod of a box-shaped profile were studied. The natural vibrations frequencies of a rod with a crack of different depth and located in different places of the rod ...were determined. The method of conducting an experiment using a vibration analyzer is given. A variant of determining the location of the crack depending on the change in the natural vibrations frequency is proposed. The resulting expression for estimating the location of the crack has an error of no more than 2.7 percent of the length of the rod, which makes it effective in practical application. The puchnost points of each oscillation form of the cantilever rod are determined, taking into account internal friction, which allowed us to specify the locations of sensors for maximum efficiency in evaluating the influence of crack parameters on natural frequencies. We found that when the crack is located in the places where the puchnosty for the corresponding vibration form causes noticeable energy dissipation due to friction in the crack.
The process e+e−→K+K− has been studied using 1.7×106 events from a data sample corresponding to an integrated luminosity of 5.7 pb−1 collected with the CMD-3 detector in the center-of-mass energy ...range 1010–1060 MeV. The cross section is measured with about 2% systematic uncertainty and is used to calculate the contribution to the anomalous magnetic moment of the muon aμK+K−=(19.33±0.40)×10−10, and to obtain the ϕ(1020) meson parameters. We consider the relationship between the e+e−→K+K− and e+e−→KS0KL0 cross sections and compare it to the theoretical prediction.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
We present a measurement of the pion form factor based on e+e− annihilation data from the CMD-2 detector in the energy range 0.6<s<1.0 GeV with a systematic uncertainty of 0.8%. A data sample is five ...times larger than that used in our previous measurement.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
The multi-channel optical readout of a THGEM multiplier coupled to a matrix of 3×3 Geiger-mode APDs (GAPDs) was demonstrated in a two-phase Cryogenic Avalanche Detector (CRAD) in Ar. The GAPDs ...recorded THGEM-hole avalanches in the Near Infrared (NIR) spectral range. At an avalanche charge gain of 160, the yield of the combined THGEM/GAPD-matrix multiplier amounted to ~80 photoelectrons per 20keV X-ray absorbed in the liquid phase. A spatial resolution of 2.5mm (FWHM) has been measured for the impinging X-rays. This technique has potential applications in coherent neutrino-nucleus scattering and in dark matter search experiments.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
The process e+e−→K+K−η has been studied in the center-of-mass energy range from 1.59 to 2.007 GeV using the data sample of 59.5 pb−1, collected with the CMD-3 detector at the VEPP-2000 e+e− collider ...in 2011, 2012 and 2017. The K+K−η final state is found to be dominated by the contribution of the ϕ(1020)η intermediate state. The cross section of the process e+e−→ϕ(1020)η has been measured with a systematic uncertainty of 5.1% on the base of 3009 ± 67 selected events. The obtained cross section has been used to calculate the contribution to the anomalous magnetic moment of the muon: aμϕη(E<1.8GeV)=(0.321±0.015stat±0.016syst)×10−10, aμϕη(E<2.0GeV)=(0.440±0.015stat±0.022syst)×10−10. From the cross section approximation the ϕ(1680) meson parameters have been determined with better statistical precision, than in previous studies.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
The paper describes a method of the charged particle identification, developed for the CMD-3 detector, installed at the VEPP-2000 e+e− collider. The method is based on application of boosted decision ...trees classifiers, trained for the optimal separation of electrons, muons, pions and kaons in the momentum range from 100 to 1200MeV/c. The input variables for the classifiers are linear combinations of the energy depositions of charged particles in 12 layers of the liquid xenon calorimeter of the CMD-3. The event samples for training of the classifiers are taken from the simulation. Various issues of the calorimeter strip channels response simulation and their calibration are considered. Application of the method is illustrated by the examples of separation of the e+e−(γ) and π+π−(γ) final states and of selection of the K+K− final state at high energies.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
The process e+e−→K+K−π+π− has been studied in the center-of-mass energy range from 1500 to 2000 MeV using a data sample of 23 pb−1 collected with the CMD-3 detector at the VEPP-2000 e+e− collider. ...Using about 24 000 selected events, the e+e−→K+K−π+π− cross section has been measured with a systematic uncertainty decreasing from 11.7% at 1500–1600 MeV to 6.1% above 1800 MeV. A preliminary study of K+K−π+π− production dynamics has been performed.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK