A
bstract
The cross section of the process
e
+
e
−
→ ηπ
+
π
−
is measured using the data collected with the CMD-3 detector at the VEPP-2000 collider in the center-of-mass energy range from 1
.
1 to 2
....
0 GeV. The decay mode
η → γγ
is used for
η
meson reconstruction in the data sample corresponding to an integrated luminosity of 78
.
3 pb
−
1
. The energy dependence of the
e
+
e
−
→ ηπ
+
π
−
cross section is fitted within the framework of vector meson dominance in order to extract the Γ(
ρ
(1450)
→ e
+
e
−
)
B
(
ρ
(1450)
→ ηπ
+
π
−
) and the Γ(
ρ
(1700)
→ e
+
e
−
)
B
(
ρ
(1700)
→ ηπ
+
π
−
) products. Based on conservation of vector current, the analyzed data are used to test the relationship between the
e
+
e
−
→ ηπ
+
π
−
cross section and the spectral function in
τ
−
→ ηπ
−
π
0
ντ
decay. The
e
+
e
−
→ ηπ
+
π
−
cross section obtained with the CMD-3 detector is in good agreement with the previous measurements.
Since December 2010 the CMD-3 and SND detectors detectors collect data at the VEPP-2000 electron-positron collider. In 2013-2015 the injection facility of the collider has undergone an upgrade of the ...injection system. The new BINP injection complex has been connected to the VEPP-2000 collider, so the restrictions connected to the lack of positrons and limited beam energy transfer do not apply any more. The collider luminosity in whole energy range is restricted now only by beam-beam effects. VEPP-2000 collider started to collect data with two detectors at 2016 year. The collected data sample since 2010 corresponds more than 100 pb
-1
of integrated luminosity per detector in the c.m. energy between 0.32 and 2GeV. We will report here results of analysis of various hadronic cross sections from detectors both published and preliminary. These measurements are important by themselves and also because of the implications for anomaly of the magnetic moment of a muon (g-2) discrepancy.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
This paper reports measurements of the hadronic cross sections with the CMD-3 detector at the VEPP-2000 electron-positron collider. The overall size of the data sample analyzed is about 60 pb-1, ...collected by the CMD- 3 running since December 2010 up to June 2013 in the c.m. energy range from 0.32 to 2.0 GeV. The preliminary results of data analysis for various modes of e+e−→hadrons are discussed.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
The cross-section of the process e+e−→π+π− has been measured using about 114000 events collected by the CMD-2 detector at the VEPP-2M e+e− collider in the center-of-mass energy range from 0.61 to ...0.96 GeV. Results of the pion form factor determination with a 0.6% systematic uncertainty are presented. The following values of the ρ- and ω-meson parameters were found: Mρ=(776.09±0.81) MeV, Γρ=(144.46±1.55) MeV, Γ(ρ→e+e−)=(6.86±0.12) keV, Br(ω→π+π−)=(1.33±0.25)%. Implications for the hadronic contribution to the muon anomalous magnetic moment are discussed.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
Calorimetry of the CMD-3 detector Akhmetshin, R R; Anisenkov, A V; Aulchenko, V M ...
Journal of physics. Conference series,
11/2017, Volume:
928, Issue:
1
Journal Article
Peer reviewed
Open access
The CMD-3 detector has been collecting data since 2010 at the e+e− collider VEPP-2000 in the Budker Institute of Nuclear Physics. VEPP-2000 uses the novel round beam technique and provides high ...luminosity in a wide c.m.energy range from 0.32 to 2 GeV. The physics goal of the CMD-3 experiment is a study of the e+e− annihilation into hadrons. CMD-3 is a general-purpose detector, which provides high efficiency for both charged and neutral particles. The electromagnetic calorimeter consists of the barrel calorimeter based on liquid xenon and CsI crystals, and the endcap calorimeter based on BGO crystals. The main parameters of the calorimeters are presented.
Characteristic properties of two-phase avalanche detectors are further studied. Such detectors are relevant in the field of coherent neutrino-nucleus scattering, dark matter search and positron ...emission tomography (PET). The detectors investigated comprised a liquid Ar, Ar+N2 or Xe layer followed by a multi-GEM multiplier with CsI photocathode operated in saturated vapor. It was found that doping of two-phase Ar with N2 removed the slow electron emission component, existing in two-phase Ar, and enhanced the fast component. The electron emission efficiency was close to 100% both in two-phase Ar and Ar+N2 even at lower electric fields. The detection of 511keV gamma-ray induced signals was demonstrated in two-phase Ar (scintillation signals) and two-phase Xe (ionization signals) avalanche detectors, in connection with PET applications.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
49.
Recent results on the properties of two-phase argon avalanche detectors Bondar, A.; Buzulutskov, A.; Grebenuk, A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
2009, 2009-1-00, Volume:
598, Issue:
1
Journal Article
Peer reviewed
Open access
The characteristic properties of two-phase argon (Ar) avalanche detectors, including those obtained with CsI photocathode, are further studied. Such detectors are relevant in the field of coherent ...neutrino-nucleus scattering and dark-matter search experiments. The detectors investigated comprised a 1
cm thick liquid Ar layer followed by a triple-gas electron multipliers (GEMs). In these detectors, typical gains reaching 10
4 were obtained with good reproducibility and a stable operation for at least 1 day was demonstrated. Amplitude and pulse-shape characteristics are presented under irradiation with X-rays, gamma rays and neutrons from different radioactive sources. The detection of both primary scintillation and ionization signals at higher gains, at a deposited energy of 60
keV, has been demonstrated.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
Barrel calorimeter of the CMD-3 detector Anisenkov, A.V.; Aulchenko, V.M.; Barkov, L.M. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2013, Volume:
732
Journal Article
Peer reviewed
Since 2010 the CMD-3 detector has been collecting data at the e+e− collider VEPP-2000 at Budker Institute of Nuclear Physics. CMD-3 is a general purpose detector designed to study e+e− annihilation ...into hadrons in the wide energy range s=0.3–2GeV. The CMD-3 barrel electromagnetic calorimeter consists of two subsystems: closest to the beam pipe is the Liquid Xenon calorimeter and the outer one is based on CsI scintillation crystals. The design of the calorimeter and its current performance are presented.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK