Full text
Available for:
BFBNIB, DOBA, FZAB, GIS, IJS, IZUM, KILJ, NLZOH, NUK, OILJ, PILJ, PNG, SAZU, SBCE, SBMB, SIK, UILJ, UKNU, UL, UM, UPUK, VSZLJ
2.
QRS-T Angle: A Review Oehler, Andrew; Feldman, Trevor; Henrikson, Charles A. ...
Annals of noninvasive electrocardiology,
November 2014, Volume:
19, Issue:
6
Journal Article
Peer reviewed
Open access
For proper distribution of preventative resources, a more robust method of cardiac risk stratification should be encouraged in addition to merely reduced ejection fraction. To this end, the QRS‐T ...angle, an electrocardiogram‐derived measure of the difference in mean vectors of depolarization and repolarization, has been found associated with sudden cardiac death and other mortal and morbid outcomes in multiple observational studies over the past decade. The use of both frontal and spatial QRS‐T angle in the prediction of future cardiac events including sudden cardiac death, all‐cause mortality, and further cardiac morbidity is reviewed here.
Full text
Available for:
BFBNIB, FZAB, GIS, IJS, KILJ, NLZOH, NUK, OILJ, SAZU, SBCE, SBMB, UL, UM, UPUK
Objectives This study was designed to assess the risk of significant bleeding complications in patients receiving antiplatelet or anticoagulation medications at the time of implantable ...cardioverter-defibrillator (ICD) device implantation. Background Periprocedural management of antiplatelet or anticoagulation therapy at the time of device implantation remains controversial. Methods We performed a retrospective chart review of bleeding complications in all patients undergoing ICD or pacemaker implantation from August 2004 to August 2007. Aspirin or clopidogrel use was defined as taken within 5 days of the procedure. A significant bleeding complication was defined as need for pocket exploration or blood transfusion; hematoma requiring pressure dressing or change in anticoagulation therapy; or prolonged hospitalization. Results Of the 1,388 device implantations, 71 had bleeding complications (5.1%). Compared with controls not taking antiplatelet agents (n = 255), the combination of aspirin and clopidogrel (n = 139) significantly increased bleeding risk (7.2% vs. 1.6%; p = 0.004). In patients taking aspirin alone (n = 536), bleeding risk was marginally higher than it was for patients taking no antiplatelet agents (3.9% vs. 1.6%, p = 0.078). The use of periprocedural heparin (n = 154) markedly increased risk of bleeding when compared with holding warfarin until the international normalized ratio (INR) was normal (n = 258; 14.3% vs. 4.3%; p < 0.001) and compared with patients receiving no anticoagulation therapy (14.3% vs.1.6%; p < 0.0001). There was no statistical difference in bleeding risk between patients continued on warfarin with an INR ≥1.5 (n = 46) and patients who had warfarin withheld until the INR was normal (n = 258; 6.5% vs. 4.3%; p = 0.50). Conclusions Dual antiplatelet therapy and periprocedural heparin significantly increase the risk of bleeding complications at the time of pacemaker or ICD implantation.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
The reported complication rate of catheter ablation of atrial fibrillation (AF) varies.
Our goal was to assess temporal trends and the effect of both institutional and individual operators' ...experience on the incidence of complications.
All patients undergoing AF ablation at Johns Hopkins Hospital between February 2001 and December 2010 were prospectively enrolled in a database. Major complications were defined as those that were life-threatening, resulted in permanent harm, required intervention, or significantly prolonged hospitalization.
Fifty-six major complications occurred in 1190 procedures (4.7%). The majority of complications were vascular (18; 1.5%), followed by pericardial tamponade (13; 1.1%) and cerebrovascular accident (12; 1.1%). No cases of death or atrioesophageal fistula occurred. The overall complication rate decreased from 11.1% in 2002 to 1.6% in 2010 (P <.05). On univariate analysis, demographic and clinical factors associated with the increased risk of complications were CHADS(2) score of ≥2 (hazard ratio HR = 2.5; 95% confidence interval CI = 1.4-4.4; P = .002), female gender (HR = 2.0; 95% CI = 1.2-3.5; P = .014), and age (HR = 1.03; 95% CI = 1.0-1.1; P = .042). Gender and CHADS(2) score of ≥2 remained independent predictors of complication on multivariable analysis.
The complication rate of catheter ablation of AF decreased with increased institutional experience. Female gender and CHADS(2) score of ≥2 are significant independent risk factors for complications and should be considered when referring patients for AF ablation.
...among patients with ischemic stroke and no prior evidence of AF, ILR was associated with a significantly higher rate of AF detection over 1-year follow-up. All authors are requested to disclose ...any actual or potential conflict of interest including any financial, personal or other relationships with other people or organizations within three years of beginning the submitted work that could inappropriately influence, or be perceived to influence, their work. If there are no conflicts of interest, the COI should read: “The authors report no relationships that could be construed as a conflict of interest”.Disclosures The authors have no conflicts of interest to disclose.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Shifty Protons and the Compensatory Pause Levin, Benjamin; Henrikson, Charles A.
JACC. Clinical electrophysiology,
June 2023, 2023-06-00, 20230601, Volume:
9, Issue:
6
Journal Article
Peer reviewed
Open access
Display omitted
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Introduction: Pulmonary vein (PV) isolation by catheter ablation is an increasingly used strategy to treat atrial fibrillation (AF). Complication rates from AF ablation reported in different case ...series vary widely. We conducted a retrospective analysis of 641 consecutive ablation procedures to assess complication rates, temporal trends, and clinical predictors of adverse outcomes.
Methods: All patients (n = 517) undergoing catheter ablation for AF at Johns Hopkins Hospital between February, 2001 and June, 2007 were prospectively enrolled in a database. Data from 641 consecutive procedures were analyzed and complications considered if they occurred within 30 days of ablation. Major complications were defined as those that required intervention, resulted in long‐term disability, or prolonged hospitalization.
Results: Thirty‐two major complications occurred in 641 procedures (5%). Among the patients with major complications, seven had cerebrovascular accident (CVA), eight had tamponade, one had PV occlusion with hemoptysis, and 11 had vascular injury requiring surgical repair and/or transfusion. No periprocedural deaths occurred, and no instances of esophageal injury were seen. Complication rates were higher during the first 100 cases (9.0%) than during the subsequent 541 (4.3%). Major adverse clinical events were associated with age > 70 years (P = 0.007; odds ratio 3.7, 95% confidence interval 1.4–9.6) and female gender (P = 0.014; odds ratio 3.0, 95% confidence interval 1.3–7.2). No other clinical or procedural predictors of complication were identified.
Conclusions: Complication rates from AF ablation remain significant, despite improved techniques and increased awareness of procedural risks. Both advanced age and female gender predict major adverse events, suggesting careful consideration of the risk/benefit profile in these patients prior to ablation.
Full text
Available for:
BFBNIB, DOBA, FZAB, GIS, IJS, IZUM, KILJ, NLZOH, NUK, OILJ, PILJ, PNG, SAZU, SBCE, SBMB, SIK, UILJ, UKNU, UL, UM, UPUK, VSZLJ