2D ferroelectric material has emerged as an attractive building block for high‐density data storage nanodevices. Although monolayer van der Waals ferroelectrics have been theoretically predicted, a ...key experimental breakthrough for such calculations is still not realized. Here, hexagonally stacking α‐In2Se3 nanoflake, a rarely studied van der Waals polymorph, is reported to exhibit out‐of‐plane (OOP) and in‐plane (IP) ferroelectricity at room temperature. Ferroelectric multidomain states in a hexagonal α‐In2Se3 nanoflake with uniform thickness can survive to 6 nm. Most strikingly, the electric‐field‐induced polarization switching and hysteresis loop are, respectively, observed down to the bilayer and monolayer (≈1.2 nm) thicknesses, which designates it as the thinnest layered ferroelectric and verifies the corresponding theoretical calculation. In addition, two types of ferroelectric nanodevices employing the OOP and IP polarizations in 2H α‐In2Se3 are developed, which are applicable for nonvolatile memories and heterostructure‐based nanoelectronics/optoelectronics.
The thinnest layered ferroelectric is demonstrated for the first time at room temperature. The semiconducting hexagonal α‐In2Se3 nanoflakes exhibit out‐of‐plane and in‐plane ferroelectricity that are closely intercorrelated. The polarization switching and hysteresis loops can be realized in the thickness as thin as ≈2.3 nm (bilayer) and ≈1.2 nm (monolayer). Two types of ferroelectric switchable devices are proposed to show the potential application in nonvolatile memories.
Full text
Available for:
BFBNIB, FZAB, GIS, IJS, KILJ, NLZOH, NUK, OILJ, SBCE, SBMB, UL, UM, UPUK
We aim to establish a multicenter registry collecting clinical, imaging, and follow-up data for patients who undergo myocardial perfusion imaging (MPI) with the latest generation SPECT scanners.
...REFINE SPECT (REgistry of Fast Myocardial Perfusion Imaging with NExt generation SPECT) uses a collaborative design with multicenter contribution of clinical data and images into a comprehensive clinical-imaging database. All images are processed by quantitative software. Over 290 individual imaging variables are automatically extracted from each image dataset and merged with clinical variables. In the prognostic cohort, patient follow-up is performed for major adverse cardiac events. In the diagnostic cohort (patients with correlating invasive angiography), angiography and revascularization results within 6 months are obtained.
To date, collected prognostic data include scans from 20,418 patients in 5 centers (57% male, 64.0 ± 12.1 years) who underwent exercise (48%) or pharmacologic stress (52%). Diagnostic data include 2079 patients in 9 centers (67% male, 64.7 ± 11.2 years) who underwent exercise (39%) or pharmacologic stress (61%).
The REFINE SPECT registry will provide a resource for collaborative projects related to the latest generation SPECT-MPI. It will aid in the development of new artificial intelligence tools for automated diagnosis and prediction of prognostic outcomes.
Full text
Available for:
EMUNI, FZAB, GEOZS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NUK, OILJ, PNG, SAZU, SBCE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
Combined analysis of SPECT myocardial perfusion imaging (MPI) performed with a solid-state camera on patients in 2 positions (semiupright, supine) is routinely used to mitigate attenuation artifacts. ...We evaluated the prediction of obstructive disease from combined analysis of semiupright and supine stress MPI by deep learning (DL) as compared with standard combined total perfusion deficit (TPD).
1,160 patients without known coronary artery disease (64% male) were studied. Patients underwent stress
Tc-sestamibi MPI with new-generation solid-state SPECT scanners in 4 different centers. All patients had on-site clinical reads and invasive coronary angiography correlations within 6 mo of MPI. Obstructive disease was defined as at least 70% narrowing of the 3 major coronary arteries and at least 50% for the left main coronary artery. Images were quantified at Cedars-Sinai. The left ventricular myocardium was segmented using standard clinical nuclear cardiology software. The contour placement was verified by an experienced technologist. Combined stress TPD was computed using sex- and camera-specific normal limits. DL was trained using polar distributions of normalized radiotracer counts, hypoperfusion defects, and hypoperfusion severities and was evaluated for prediction of obstructive disease in a novel leave-one-center-out cross-validation procedure equivalent to external validation. During the validation procedure, 4 DL models were trained using data from 3 centers and then evaluated on the 1 center left aside. Predictions for each center were merged to have an overall estimation of the multicenter performance.
718 (62%) patients and 1,272 of 3,480 (37%) arteries had obstructive disease. The area under the receiver operating characteristics curve for prediction of disease on a per-patient and per-vessel basis by DL was higher than for combined TPD (per-patient, 0.81 vs. 0.78; per-vessel, 0.77 vs. 0.73;
< 0.001). With the DL cutoff set to exhibit the same specificity as the standard cutoff for combined TPD, per-patient sensitivity improved from 61.8% (TPD) to 65.6% (DL) (
< 0.05), and per-vessel sensitivity improved from 54.6% (TPD) to 59.1% (DL) (
< 0.01). With the threshold matched to the specificity of a normal clinical read (56.3%), DL had a sensitivity of 84.8%, versus 82.6% for an on-site clinical read (
= 0.3).
DL improves automatic interpretation of MPI as compared with current quantitative methods.
There has been an evolutionary leap in SPECT imaging with the advent of camera systems that use solid-state crystals and novel collimator designs configured specifically for cardiac imaging. ...Solid-state SPECT camera systems have facilitated dramatic reductions in both imaging time and radiation dose while maintaining high diagnostic accuracy. These advances are related to simultaneous improvement in photon sensitivity due to the collimator and imaging geometry, as well as image resolution due to the improved energy resolution of the new crystals. Improved photon sensitivity has facilitated fast or low-dose myocardial perfusion imaging (MPI), and early dynamic imaging has emerged as a technique for assessing myocardial blood flow with SPECT. Lastly, general-purpose solid-state camera systems and hybrid SPECT/CT systems have also been developed that may have important clinical roles in cardiac imaging. This review summarizes state-of-the-art solid-state SPECT MPI technology and clinical applications, including emerging techniques for SPECT MPI flow estimation. We also discuss imaging protocols used with the new cameras, potential imaging pitfalls, and the latest data providing large-scale validation of the diagnostic and prognostic value of this new technology.
Optimal risk stratification with machine learning (ML) from myocardial perfusion imaging (MPI) includes both clinical and imaging data. While most imaging variables can be derived automatically, ...clinical variables require manual collection, which is time-consuming and prone to error. We determined the fewest manually input and imaging variables required to maintain the prognostic accuracy for major adverse cardiac events (MACE) in patients undergoing a single-photon emission computed tomography (SPECT) MPI.
This study included 20 414 patients from the multicentre REFINE SPECT registry and 2984 from the University of Calgary for training and external testing of the ML models, respectively. ML models were trained using all variables (ML-All) and all image-derived variables (including age and sex, ML-Image). Next, ML models were sequentially trained by incrementally adding manually input and imaging variables to baseline ML models based on their importance ranking. The fewest variables were determined as the ML models (ML-Reduced, ML-Minimum, and ML-Image-Reduced) that achieved comparable prognostic performance to ML-All and ML-Image. Prognostic accuracy of the ML models was compared with visual diagnosis, stress total perfusion deficit (TPD), and traditional multivariable models using area under the receiver-operating characteristic curve (AUC). ML-Minimum (AUC 0.798) obtained comparable prognostic accuracy to ML-All (AUC 0.799, P = 0.19) by including 12 of 40 manually input variables and 11 of 58 imaging variables. ML-Reduced achieved comparable accuracy (AUC 0.796) with a reduced set of manually input variables and all imaging variables. In external validation, the ML models also obtained comparable or higher prognostic accuracy than traditional multivariable models.
Reduced ML models, including a minimum set of manually collected or imaging variables, achieved slightly lower accuracy compared to a full ML model but outperformed standard interpretation methods and risk models. ML models with fewer collected variables may be more practical for clinical implementation.
Abstract
Aims
To optimize per-vessel prediction of early coronary revascularization (ECR) within 90 days after fast single-photon emission computed tomography (SPECT) myocardial perfusion imaging ...(MPI) using machine learning (ML) and introduce a method for a patient-specific explanation of ML results in a clinical setting.
Methods and results
A total of 1980 patients with suspected coronary artery disease (CAD) underwent stress/rest 99mTc-sestamibi/tetrofosmin MPI with new-generation SPECT scanners were included. All patients had invasive coronary angiography within 6 months after SPECT MPI. ML utilized 18 clinical, 9 stress test, and 28 imaging variables to predict per-vessel and per-patient ECR with 10-fold cross-validation. Area under the receiver operator characteristics curve (AUC) of ML was compared with standard quantitative analysis total perfusion deficit (TPD) and expert interpretation. ECR was performed in 958 patients (48%). Per-vessel, the AUC of ECR prediction by ML (AUC 0.79, 95% confidence interval (CI) 0.77, 0.80) was higher than by regional stress TPD (0.71, 0.70, 0.73), combined-view stress TPD (AUC 0.71, 95% CI 0.69, 0.72), or ischaemic TPD (AUC 0.72, 95% CI 0.71, 0.74), all P < 0.001. Per-patient, the AUC of ECR prediction by ML (AUC 0.81, 95% CI 0.79, 0.83) was higher than that of stress TPD, combined-view TPD, and ischaemic TPD, all P < 0.001. ML also outperformed nuclear cardiologists’ expert interpretation of MPI for the prediction of early revascularization performance. A method to explain ML prediction for an individual patient was also developed.
Conclusion
In patients with suspected CAD, the prediction of ECR by ML outperformed automatic MPI quantitation by TPDs (per-vessel and per-patient) or nuclear cardiologists’ expert interpretation (per-patient).
Stress-only myocardial perfusion imaging (MPI) markedly reduces radiation dose, scanning time, and cost. We developed an automated clinical algorithm to safely cancel unnecessary rest imaging with ...high sensitivity for obstructive coronary artery disease (CAD).
Patients without known CAD undergoing both MPI and invasive coronary angiography from REFINE SPECT were studied. A machine learning score (MLS) for prediction of obstructive CAD was generated using stress-only MPI and pre-test clinical variables. An MLS threshold with a pre-defined sensitivity of 95% was applied to the automated patient selection algorithm. Obstructive CAD was present in 1309/2079 (63%) patients. MLS had higher area under the receiver operator characteristic curve (AUC) for prediction of CAD than reader diagnosis and TPD (0.84 vs 0.70 vs 0.78, P < .01). An MLS threshold of 0.29 had superior sensitivity than reader diagnosis and TPD for obstructive CAD (95% vs 87% vs 87%, P < .01) and high-risk CAD, defined as stenosis of the left main, proximal left anterior descending, or triple-vessel CAD (sensitivity 96% vs 89% vs 90%, P < .01).
The MLS is highly sensitive for prediction of both obstructive and high-risk CAD from stress-only MPI and can be applied to a stress-first protocol for automatic cancellation of unnecessary rest imaging.
Full text
Available for:
EMUNI, FZAB, GEOZS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NUK, OILJ, PNG, SAZU, SBCE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
Upper reference limits for transient ischemic dilation (TID) have not been rigorously established for cadmium-zinc-telluride (CZT) camera systems. We aimed to derive TID limits for common myocardial ...perfusion imaging protocols utilizing a large, multicenter registry (REFINE SPECT).
One thousand six hundred and seventy-two patients with low likelihood of coronary artery disease with normal perfusion findings were identified. Images were processed with Quantitative Perfusion SPECT software (Cedars-Sinai Medical Center, Los Angeles, CA). Non-attenuation-corrected, camera-, radiotracer-, and stress protocol-specific TID limits in supine position were derived from 97.5th percentile and mean + 2 standard deviations (SD). Reference limits were compared for different solid-state cameras (D-SPECT vs. Discovery), radiotracers (technetium-99m-sestamibi vs. tetrofosmin), different types of stress (exercise vs. four different vasodilator-based protocols), and different vasodilator-based protocols.
TID measurements did not follow Gaussian distribution in six out of eight subgroups. TID limits ranged from 1.18 to 1.52 (97.5th percentile) and 1.18 to 1.39 (mean + 2SD). No difference was noted between D-SPECT and Discovery cameras (P = 0.71) while differences between exercise and vasodilator-based protocols (adenosine, regadenoson, or regadenoson-walk) were noted (all P < 0.05).
We used a multicenter registry to establish camera-, radiotracer-, and protocol-specific upper reference limits of TID for supine position on CZT camera systems. Reference limits did not differ between D-SPECT and Discovery camera.
Full text
Available for:
EMUNI, FZAB, GEOZS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NUK, OILJ, PNG, SAZU, SBCE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
Diabetes mellitus (DM) is increasingly prevalent among contemporary populations referred for cardiac stress testing, but its potency as a predictor for major adverse cardiovascular events (MACE) vs ...other clinical variables is not well delineated.
From 19,658 patients who underwent SPECT-MPI, we identified 3122 patients with DM without known coronary artery disease (CAD) (DM+/CAD−) and 3564 without DM with known CAD (DM−/CAD+). Propensity score matching was used to control for the differences in characteristics between DM+/CAD− and DM−/CAD+ groups. There was comparable MACE in the matched DM+/CAD− and DM−/CAD+ groups (HR 1.15, 95% CI 0.97-1.37). By Chi-square analysis, type of stress (exercise or pharmacologic), total perfusion deficit (TPD), and left ventricular function were the most potent predictors of MACE, followed by CAD and DM status. The combined consideration of mode of stress, TPD, and DM provided synergistic stratification, an 8.87-fold (HR 8.87, 95% CI 7.27-10.82) increase in MACE among pharmacologically stressed patients with DM and TPD > 10% (vs non-ischemic, exercised stressed patients without DM).
Propensity-matched patients with DM and no known CAD have similar MACE risk compared to patients with known CAD and no DM. DM is synergistic with mode of stress testing and TPD in predicting the risk of cardiac stress test patients.
Full text
Available for:
EMUNI, FZAB, GEOZS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NUK, OILJ, PNG, SAZU, SBCE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ