This study reports the development of prototype swept-source optical coherence tomography (SS-OCT) technology for imaging the anterior eye. Advances in vertical-cavity surface-emitting laser (VCSEL) ...light sources, signal processing, optics and mechanical designs, enable a unique combination of high speed, long range, and deep penetration that addresses the challenges of anterior eye imaging. We demonstrate SS-OCT with a 325 kHz A-scan rate, 12.2 µm axial resolution (in air), and 15.5 mm depth range (in air) at 1310 nm wavelength. The ultrahigh 325 kHz A-scan rate not only facilitates biometry measurements by minimizing acquisition time and thus reducing motion, but also enables volumetric OCT for comprehensive structural analysis and OCT angiography (OCTA) for visualizing vasculature. The 15.5 mm (~ 11.6 mm in tissue) depth range spans all optical surfaces from the anterior cornea to the posterior lens capsule. The 1310 nm wavelength range enables structural OCT and OCTA deep in the sclera and through the iris. Achieving high speed and long range requires linearizing the VCSEL wavenumber sweep to efficiently utilize analog-to-digital conversion bandwidth. Dual channel recording of the OCT and calibration interferometer fringe signals, as well as sweep to sweep wavenumber compensation, is used to achieve invariant 12.2 µm (~ 9.1 µm in tissue) axial resolution and optimum point spread function throughout the depth range. Dynamic focusing using a tunable liquid lens extends the effective depth of field while preserving the lateral resolution. Improved optical and mechanical design, including parallax "split view" iris cameras and stable, ergonomic patient interface, facilitates accurate instrument positioning, reduces patient motion, and leads to improved imaging data yield and measurement accuracy. We present structural and angiographic OCT images of the anterior eye, demonstrating the unique imaging capabilities using representative scanning protocols which may be relevant to future research and clinical applications.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
Adoptive cell transfer against solid tumors faces challenges to overcome tumor microenvironment (TME), which plays as a physical barrier and provides immuno-suppressive conditions. Classical ...cytotoxicity assays are widely used to measure killing ability of the engineered cytotoxic lymphocytes as therapeutics, but the results cannot represent the performance in clinical application due to the absence of the TME. This paper describes a 3D cytotoxicity assay using an injection molded plastic array culture (CACI-IMPACT) device for 3D cytotoxicity assay to assess killing abilities of cytotoxic lymphocytes in 3D microenvironment through a spatiotemporal analysis of the lymphocytes and cancer cells embedded in 3D extra cellular matrix (ECM). Rail-based microfluidic design was integrated within a single 96-well and the wells were rectangularly arrayed in 2 × 6 to enhance the experimental throughput. The rail-based microstructures facilitate hydrogel patterning with simple pipetting so that hydrogel pre-solution aspirated with 10 μl pipette can be patterned in 10 wells within 30 s. To demonstrate 3D cytotoxicity assay, we patterned HeLa cells encapsulated by collagen gel and observed infiltration, migration and cytotoxic activity of NK-92 cells against HeLa cells in the collagen matrix. We found that 3D ECM significantly reduced migration of cytotoxic lymphocytes and access to cancer cells, resulting in lower cytotoxicity compared with 2D assays. In dense ECM, the physical barrier function of the 3D matrix was enhanced, but the cytotoxic lymphocytes effectively killed cancer cells once they contacted with cancer cells. The results implied ECM significantly influences migration and cytotoxicity of cytotoxic lymphocytes. Hence, the CACI-IMPACT platform, enabling high-throughput 3D co-culture of cytotoxic lymphocyte with cancer cells, has the potential to be used for pre-clinical evaluation of cytotoxic lymphocytes engineered for immunotherapy against solid tumors.
Microfluidic organ-on-a-chip technologies have enabled construction of biomimetic physiologically and pathologically relevant models. This paper describes an injection molded microfluidic platform ...that utilizes a novel sequential edge-guided patterning method based on spontaneous capillary flow to realize three-dimensional co-culture models and form an array of micro-vascularized tissues (28 per 1 × 2-inch slide format). The MicroVascular Injection-Molded Plastic Array 3D Culture (MV-IMPACT) platform is fabricated by injection molding, resulting in devices that are reliable and easy to use. By patterning hydrogels containing human umbilical endothelial cells and fibroblasts in close proximity and allowing them to form vasculogenic networks, an array of perfusable vascularized micro-tissues can be formed in a highly efficient manner. The high-throughput generation of angiogenic sprouts was quantified and their uniformity was characterized. Due to its compact design (half the size of a 96-well microtiter plate), it requires small amount of reagents and cells per device. In addition, the device design is compatible with a high content imaging machine such as Yokogawa CQ-1. Furthermore, we demonstrated the potential of our platform for high-throughput phenotypic screening by testing the effect of DAPT, a chemical known to affect angiogenesis. The MV-IMPACT represent a significant improvement over our previous PDMS-based devices in terms of molding 3D co-culture conditions at much higher throughput with added reliability and robustness in obtaining vascular micro-tissues and will provide a platform for developing applications in drug screening and development.
Microfluidics offers promising methods for aligning cells in physiologically relevant configurations to recapitulate human organ functionality. Specifically, microstructures within microfluidic ...devices facilitate 3D cell culture by guiding hydrogel precursors containing cells. Conventional approaches utilize capillary forces of hydrogel precursors to guide fluid flow into desired areas of high wettability. These methods, however, require complicated fabrication processes and subtle loading protocols, thus limiting device throughput and experimental yield. Here, we present a swift and robust hydrogel patterning technique for 3D cell culture, where preloaded hydrogel solution in a microfluidic device is aspirated while only leaving a portion of the solution in desired channels. The device is designed such that differing critical capillary pressure conditions are established over the interfaces of the loaded hydrogel solution, which leads to controlled removal of the solution during aspiration. A proposed theoretical model of capillary pressure conditions provides physical insights to inform generalized design rules for device structures. We demonstrate formation of multiple, discontinuous hollow channels with a single aspiration. Then we test vasculogenic capacity of various cell types using a microfluidic device obtained by our technique to illustrate its capabilities as a viable micro-manufacturing scheme for high-throughput cellular co-culture.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
Ultrahigh resolution spectral domain-OCT (UHR SD-OCT) enables in vivo visualization of micrometric structural markers which differentially associate with normal aging versus age-related macular ...degeneration (AMD). This study explores the hypothesis that UHR SD-OCT can detect and quantify sub-retinal pigment epithelium (RPE) deposits in early AMD, separating AMD pathology from normal aging.
Prospective cross-sectional study.
A total of 53 nonexudative (dry) AMD eyes from 39 patients, and 63 normal eyes from 39 subjects.
Clinical UHR SD-OCT scans were performed using a high-density protocol. Exemplary high-resolution histology and transmission electron microscopy images were obtained from archive donor eyes. Three trained readers evaluated and labeled outer retina morphological features, including the appearance of a hyporeflective split within the RPE–RPE basal lamina (RPE-BL)–Bruch’s membrane (BrM) complex on UHR brightness (B)-scans. A semi-automatic segmentation algorithm measured the thickness of the RPE-BL-BrM split/hyporeflective band.
Qualitative description of outer retinal morphological changes on UHR SD-OCT B-scans; the proportion of the RPE-BL-BrM complex with visible split (%) and the thickness of the resulting hyporeflective band (μm).
In young normal eyes, UHR SD-OCT consistently revealed an RPE-BL-BrM split/hyporeflective band. Its visibility and thickness were less in eyes of advanced age. However, the split/hyporeflective band was again visible in early AMD eyes. Both qualitative reading and quantitative thickness measurements showed significantly elevated visibility and thickness of the RPE-BL-BrM split/hyporeflective in early AMD eyes compared to age-matched controls.
Our imaging results strongly support the hypothesis that appearance of the RPE-BL-BrM split/hyporeflective band in older subjects is dominated by the BL deposit, an indicator of early AMD well known from histology. Ultrahigh resolution SD-OCT can be used to investigate physiological aging as well as early AMD pathology in clinical imaging studies. Developing quantifiable markers associated with disease pathogenesis and progression can facilitate drug discovery, as well as reduce clinical trial times.
Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Optical coherence tomography angiography (OCTA) offers non-invasive and depth-resolved imaging of the retinal vasculature. While OCTA is widely used to study retinal disease, it traditionally ...provides limited information about blood flow speed. This thesis introduces a second-generation variable interscan time analysis (VISTA) OCTA, designed to evaluate a quantitative surrogate marker for blood flow speed in the vasculature. At the capillary level, spatially compiled OCTA and a simple temporal autocorrelation model, ρ(τ) = exp(-ατ), are used to evaluate a temporal autocorrelation decay constant, α, as a marker for blood flow speed. A 600 kHz A-scan rate swept-source OCT prototype instrument provides short interscan time OCTA and fine A-scan spacing acquisition, while maintaining multi mm2 field-of-views for human retinal imaging. The cardiac pulsatility in α is demonstrated and its synchronization across retinal capillaries is quantified. The repeatability of α measurements is evaluated at multiple spatial levels. This new approach reveals varying α values across different retinal capillary plexuses in healthy eyes, and demonstrates spatial correspondence between high blood flow speeds and the centers of choriocapillaris lobules. VISTA OCTA images of eyes with diabetic retinopathy and age-related macular degeneration are also presented. By providing blood flow speed information, the second-generation VISTA aims to enhance and complement traditional structural vasculature imaging offered by OCTA. These advancements promise to enable clinical studies of blood flow speed alterations in retinal diseases, offering earlier markers for disease detection, progression, and response to treatment.
S.M.
A micrometer scale hyporeflective band within the retinal pigment epithelium basal lamina - Bruch's membrane complex (RPE-BL-BrM) was topographically measured in aging and age-related macular ...degeneration (AMD).PurposeA micrometer scale hyporeflective band within the retinal pigment epithelium basal lamina - Bruch's membrane complex (RPE-BL-BrM) was topographically measured in aging and age-related macular degeneration (AMD).In a prospective cross-sectional study, 90 normal eyes from 76 subjects (range = 23-90 years) and 53 dry AMD eyes from 47 subjects (range = 62-91 years) were enrolled. Isotropic volume raster scans over 6 mm × 6 mm (500 × 500 A-scans) were acquired using a high-resolution (2.7 µm axial resolution) spectral-domain optical coherence tomography (SD-OCT) prototype instrument. Six consecutive optical coherence tomography (OCT) volumes were computationally motion-corrected and fused to improve feature visibility. A boundary regression neural network was developed to measure hyporeflective band thickness. Topographic dependence was evaluated over a 6-mm-diameter Early Treatment Diabetic Retinopathy Study (ETDRS) grid.MethodsIn a prospective cross-sectional study, 90 normal eyes from 76 subjects (range = 23-90 years) and 53 dry AMD eyes from 47 subjects (range = 62-91 years) were enrolled. Isotropic volume raster scans over 6 mm × 6 mm (500 × 500 A-scans) were acquired using a high-resolution (2.7 µm axial resolution) spectral-domain optical coherence tomography (SD-OCT) prototype instrument. Six consecutive optical coherence tomography (OCT) volumes were computationally motion-corrected and fused to improve feature visibility. A boundary regression neural network was developed to measure hyporeflective band thickness. Topographic dependence was evaluated over a 6-mm-diameter Early Treatment Diabetic Retinopathy Study (ETDRS) grid.The hyporeflective band thickness map (median of 4.3 µm and 7.8 µm in normal and AMD eyes, respectively) is thicker below and radially symmetric around the fovea. In normal eyes, age-associated differences occur within 0.7 to 2.3 mm from the foveal center (P < 0.05). In AMD eyes, the hyporeflective band is hypothesized to be basal laminar deposits (BLamDs) and is thicker within the 3-mm ETDRS circle (P < 0.0002) compared with normal eyes. The inner ring is the most sensitive location to detect age versus AMD-associated changes within the RPE-BL-BrM. AMD eyes with subretinal drusenoid deposits (SDDs) have a significantly thicker hyporeflective band (P < 0.001) than those without SDDs.ResultsThe hyporeflective band thickness map (median of 4.3 µm and 7.8 µm in normal and AMD eyes, respectively) is thicker below and radially symmetric around the fovea. In normal eyes, age-associated differences occur within 0.7 to 2.3 mm from the foveal center (P < 0.05). In AMD eyes, the hyporeflective band is hypothesized to be basal laminar deposits (BLamDs) and is thicker within the 3-mm ETDRS circle (P < 0.0002) compared with normal eyes. The inner ring is the most sensitive location to detect age versus AMD-associated changes within the RPE-BL-BrM. AMD eyes with subretinal drusenoid deposits (SDDs) have a significantly thicker hyporeflective band (P < 0.001) than those without SDDs.The hyporeflective band is a quantifiable biomarker which differentiates AMD from aging. Longitudinal studies are warranted. The hyporeflective band may be a useful biomarker for risk stratification and disease progression.ConclusionsThe hyporeflective band is a quantifiable biomarker which differentiates AMD from aging. Longitudinal studies are warranted. The hyporeflective band may be a useful biomarker for risk stratification and disease progression.
A novel scanning protocol, ammonite scan, is proposed for widefield optical coherence tomography angiography (OCTA) and relative retinal blood flow velocity imaging in the human retina using variable ...interscan time analysis (VISTA). A repeated circle scan using a 400 kHz swept-source was employed to achieve an interscan time of 1.28 ms. The center of the repeated circular scan continuously moved spirally towards the peripheral region, ensuring an extended and adjustable scan range while preserving the short interscan time. Image artifacts due to eye movement were eliminated via extra motion-correction processing using data redundancy. The relative blood flow velocity in superficial and deep plexus layers was calculated from the VISTA image, and their ratio was used to explore the microvascular flow parameter in the healthy human eye.
Raynaud syndrome refers to a medical condition where arterial smooth muscle contraction induces blood flow reduction. Thermal images and questionnaires have been used to assess the efficacy of ...treatment. In this research, a potential way to measure whole-hand blood circulation in real-time using infrared image is introduced. Normalized average pixel intensity of the regions of interest in hand was measured during or after blood circulation changes brought by temperature alteration and pressure applied to the hand or forearm. The intensity of regions has shown the tendency of the expected amount of blood in the hand in each blood circulation changes. Possible uses of this system are measuring severity of Raynaud syndrome and the efficacy of treatments.
Optical coherence tomography angiography (OCTA) can visualize vasculature structures, but provides limited information about blood flow speed. Here, we present a second generation variable interscan ...time analysis (VISTA) OCTA, which evaluates a quantitative surrogate marker for blood flow speed in vasculature. At the capillary level, spatially compiled OCTA and a simple temporal autocorrelation model,
(
) = exp(-
), were used to evaluate a temporal autocorrelation decay constant,
, as the blood flow speed marker. A 600 kHz A-scan rate swept-source OCT prototype instrument provides short interscan time OCTA and fine A-scan spacing acquisition, while maintaining multi mm
field of views for human retinal imaging. We demonstrate the cardiac pulsatility and assess repeatability of
measured with VISTA. We show different
for different retinal capillary plexuses in healthy eyes and present representative VISTA OCTA in eyes with diabetic retinopathy.