The potential of microRNAs (miRNA) as non-invasive diagnostic, prognostic, and predictive biomarkers, as well as therapeutic targets, has recently been recognized. Previous studies have highlighted ...the importance of consistency in the methodology used, but to our knowledge, no study has described the methodology of sample preparation and storage systematically with respect to miRNAs as blood biomarkers. The aim of this study was to investigate the stability of miRNAs in blood under various relevant clinical and research conditions: different collection tubes, storage at different temperatures, physical disturbance, as well as serial freeze-thaw cycles.
Blood samples were collected from 12 healthy donors into different collection tubes containing anticoagulants, including EDTA, citrate and lithium-heparin, as well as into serum collection tubes. MiRNA stability was evaluated by measuring expression changes of miR-1, miR-21 and miR-29b at different conditions: varying processing time of whole blood (up to 72 hours (h)), long-term storage (9 months at -80°C), physical disturbance (1 and 8 h), as well as in a series of freeze/thaw cycles (1 and 4 times).
Different collection tubes revealed comparable concentrations of miR-1, miR-21 and miR-29b. Tubes with lithium-heparin were found unsuitable for miRNA quantification. MiRNA levels were stable for at least 24 h at room temperature in whole blood, while separated fractions did show alterations within 24 h. There were significant changes in the miR-21 and miR-29b levels after 72 h incubation of whole blood at room temperature (p<0.01 for both). Both miR-1 and miR-21 showed decreased levels after physical disturbance for 8 h in separated plasma and miR-1 in serum whole blood, while after 1 h of disturbance no changes were observed. Storage of samples at -80°C extended the miRNA stability remarkably, however, miRNA levels in long-term stored (9 months) whole blood samples were significantly changed, which is in contrast to the plasma samples, where miR-21 or miR-29b levels were found to be stable. Repetitive (n = 4) freeze-thaw cycles resulted in a significant reduction of miRNA concentration both in plasma and serum samples.
This study highlights the importance of proper and systematic sample collection and preparation when measuring circulating miRNAs, e.g., in context of clinical trials. We demonstrated that the type of collection tubes, preparation, handling and storage of samples should be standardized to avoid confounding variables influencing the results.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Arrhythmias are common and contribute substantially to cardiovascular morbidity and mortality. The underlying pathophysiology of arrhythmias is complex and remains incompletely understood, which ...explains why mostly only symptomatic therapy is available. The evaluation of the complex interplay between various cell types in the heart, including cardiomyocytes from the conduction system and the working myocardium, fibroblasts and cardiac immune cells, remains a major challenge in arrhythmia research because it can be investigated only in vivo. Various animal species have been used, and several disease models have been developed to study arrhythmias. Although every species is useful and might be ideal to study a specific hypothesis, we suggest a practical trio of animal models for future use: mice for genetic investigations, mechanistic evaluations or early studies to identify potential drug targets; rabbits for studies on ion channel function, repolarization or re-entrant arrhythmias; and pigs for preclinical translational studies to validate previous findings. In this Review, we provide a comprehensive overview of different models and currently used species for arrhythmia research, discuss their advantages and disadvantages and provide guidance for researchers who are considering performing in vivo studies.
Full text
Available for:
EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
Risks of catheter ablation for atrial fibrillation and flutter assessed in retrospective studies, registries, and controlled trials may underestimate 'real world' conditions.
To assess complications ...in a nationwide approach, we included all cases undergoing catheter ablation for atrial fibrillation and atrial flutter in Germany in 2014, using ICD-10-GM-based German Diagnosis Related Group (G-DRG) codes and the well differentiated German Operation and Procedure Classification (OPS) analysing 33 353 in-hospital cases. For left atrial ablations (19 514 cases), the overall complication rate ranged from a mean of 11.7% to 13.8% depending on type and site of applied energy, including major complications ranging from 3.8% to 7.2%. Whereas overall complication rates were lower for atrial flutter ablations (13 871 cases, 10.5%; P < 0.001), interestingly, major complications occurred more frequently (7.4%; P < 0.001). Particularly, in-hospital death was four-times more common following right than following left atrial ablations (47 vs. 18 cases, 0.34% vs. 0.09%; P < 0.001). Stratified by centre ablation volume, significantly fewer overall complications occurred in centres performing >100 vs. ≤100 left atrial ablations annually (12.7% vs. 16.4%; P < 0.002).
Administrative data of all atrial fibrillation ablations in Germany in 2014 revealed higher overall and major complication rates than previously reported. Few patients were treated in low volume centres, but were exposed to a higher overall complication risk. Atrial flutter ablations were associated with surprisingly high rates of life-threatening complications. Advanced age combined with highly prevalent cardiac, pulmonary and, vascular comorbidities likely play a major role. In addition, individual-level clinical studies need to address the safety and benefits of catheter ablation in an elderly, diseased population.
The subcutaneous implantable cardioverter-defibrillator (S-ICD) is a potential alternative to transvenous systems in hypertrophic cardiomyopathy (HCM) where lead complications are a significant ...issue.
To compare the S-ICD efficacy of defibrillation threshold (DFT) testing, arrhythmia therapy, and complications in HCM versus non-HCM patients.
Outcomes of patients with HCM implanted with S-ICD were compared to non-HCM S-ICD recipients using pooled data from a total of 872 subjects enrolled in the EFFORTLESS Registry and US IDE study.
The cohort included 99 HCM (75% male) and 773 non-HCM (72% male) patients with a median follow-up of 637 days. The HCM cohort was younger and more likely to receive a primary-prevention S-ICD (88.5% vs 67.5%, P < .0001). During implant testing, successful defibrillation at ≤80 J was achieved in 98.9% of HCM and 98.5% of non-HCM patients. One year postoperative complication-free rates were similar: 92.7% in HCM (with no lead complications) versus 89.5% in non-HCM. There were 3 appropriate shocks for ventricular tachycardia in 3 HCM patients that were all converted by the first shock. Overall final shock conversion efficacy was 100% in HCM versus 98% in non-HCM (P = ns). Inappropriate shocks occurred in 12.5% of HCM patients and 10.3% of non-HCM patients (P = ns), being reduced by 47% using dual-zone programming.
These initial data indicate the S-ICD is safe and effective in patients with HCM who are at high risk of ventricular arrhythmias and pass preimplantation electrocardiogram screening. Inappropriate shocks were mainly due to T-wave oversensing, but there were no lead complications requiring reintervention.
Abstract
This document describes the contribution of clinical criteria to the interpretation of genetic variants using heritable Mendelian cardiomyopathies as an example. The aim is to assist ...cardiologists in defining the clinical contribution to a genetic diagnosis and the interpretation of molecular genetic reports. The identification of a genetic variant of unknown or uncertain significance is a limitation of genetic testing, but current guidelines for the interpretation of genetic variants include essential contributions from clinical family screening that can establish a de novo assignment of the variant or its segregation with the phenotype in the family. A partnership between clinicians and patients helps to solve major uncertainties and provides reliable and clinically actionable information.
Graphical Abstract
Impact of the cardiologic phenotyping of probands and relatives on ACMG criteria. The ideal ‘drawing’ of the family pedigree is complete and correct when all available family members have been clinically evaluated and, eventually, longitudinally monitored. *Cardiologists and geneticists may add their own experience, data, and local population information. oEndomyocardial biopsy - anti-GB3 immuno-stain (positive brown; §Typical ultrastructural pattern. DCM = dilated cardiomyopathy; HCM = hypertrophic cardiomyopathy; RCM = restrictive cardiomyopathy; ACM = arrhythmogenic cardiomyopathy; ASD = atrial septal defect; VSD = ventricular septal defect; GB3 = globotriaosylceramide.
•Heart exposure is a major cardiac risk factor in left-sided breast cancer survivors.•Deep inspiration breath-hold (DIBH) significantly reduces the exposure of the heart.•Patients with high ...cardiovascular risk and favourable tumour prognosis benefit most.•Risk modelling showed that age has only minor impact on the related cardiac risk.
Aim of the current comparative modelling study was to estimate the individual radiation-induced risk for death of ischaemic heart disease (IHD) under free breathing (FB) and deep inspiration breath-hold (DIBH) in a real-world population.
Eighty-nine patients with left-sided early breast cancer were enrolled in the prospective SAVE-HEART study. For each patient three-dimensional conformal treatment plans were created in FB and DIBH and corresponding radiation-induced risks of IHD mortality were estimated based on expected survival, individual IHD risk factors and the relative radiation-induced risk.
With the use of DIBH, mean heart doses were reduced by 35% (interquartile range: 23–46%) as compared to FB. Mean expected years of life lost (YLL) due to radiation-induced IHD mortality were 0.11 years in FB, and 0.07 years in DIBH. YLL were remarkably independent of age at treatment in patients with a favourable tumour prognosis. DIBH led to more pronounced reductions in YLL in patients with high baseline risk (0.08 years for upper vs 0.02 years for lower quartile), with favourable tumour prognosis (0.05 years for patients without vs 0.02 years for those with lymph-node involvement), and in patients with high mean heart doses in FB (0.09 years for doses >3 Gy vs 0.02 years for doses <1.5 Gy).
Ideally, the DIBH technique should be offered to all patients with left-sided breast cancer. However, highest benefits are expected for patients with a favourable tumour prognosis, high mean heart dose or high baseline IHD risk, independent of their age.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Early repolarization pattern (ERP) on electrocardiogram was associated with idiopathic ventricular fibrillation and sudden cardiac arrest in a case-control study and with cardiovascular mortality in ...a Finnish community-based sample. We sought to determine ERP prevalence and its association with cardiac and all-cause mortality in a large, prospective, population-based case-cohort study (Monitoring of Cardiovascular Diseases and Conditions MONICA/KORA Cooperative Health Research in the Region of Augsburg) comprised of individuals of Central-European descent.
Electrocardiograms of 1,945 participants aged 35-74 y, representing a source population of 6,213 individuals, were analyzed applying a case-cohort design. Mean follow-up was 18.9 y. Cause of death was ascertained by the 9th revision of the International Classification of Disease (ICD-9) codes as documented in death certificates. ERP-attributable effects on mortality were determined by a weighted Cox proportional hazard model adjusted for covariables. Prevalence of ERP was 13.1% in our study. ERP was associated with cardiac and all-cause mortality, most pronounced in those of younger age and male sex; a clear ERP-age interaction was detected (p = 0.005). Age-stratified analyses showed hazard ratios (HRs) for cardiac mortality of 1.96 (95% confidence interval CI 1.05-3.68, p = 0.035) for both sexes and 2.65 (95% CI 1.21-5.83, p = 0.015) for men between 35-54 y. An inferior localization of ERP further increased ERP-attributable cardiac mortality to HRs of 3.15 (95% CI 1.58-6.28, p = 0.001) for both sexes and to 4.27 (95% CI 1.90-9.61, p<0.001) for men between 35-54 y. HRs for all-cause mortality were weaker but reached significance.
We found a high prevalence of ERP in our population-based cohort of middle-aged individuals. ERP was associated with about a 2- to 4-fold increased risk of cardiac mortality in individuals between 35 and 54 y. An inferior localization of ERP was associated with a particularly increased risk. Please see later in the article for the Editors' Summary.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
This international multidisciplinary document intends to provide clinicians with evidence-based practical patient-centered recommendations for evaluating patients and decedents with (aborted) sudden ...cardiac arrest and their families. The document includes a framework for the investigation of the family allowing steps to be taken, should an inherited condition be found, to minimize further events in affected relatives. Integral to the process is counseling of the patients and families, not only because of the emotionally charged subject, but because finding (or not finding) the cause of the arrest may influence management of family members. The formation of multidisciplinary teams is essential to provide a complete service to the patients and their families, and the varied expertise of the writing committee was formulated to reflect this need. The document sections were divided up and drafted by the writing committee members according to their expertise. The recommendations represent the consensus opinion of the entire writing committee, graded by Class of Recommendation and Level of Evidence. The recommendations were opened for public comment and reviewed by the relevant scientific and clinical document committees of the Asia Pacific Heart Rhythm Society (APHRS) and the Heart Rhythm Society (HRS); the document underwent external review and endorsement by the partner and collaborating societies. While the recommendations are for optimal care, it is recognized that not all resources will be available to all clinicians. Nevertheless, this document articulates the evaluation that the clinician should aspire to provide for patients with sudden cardiac arrest, decedents with sudden unexplained death, and their families.
Atrial fibrillation (AF) is a major healthcare challenge contributing to high morbidity and mortality. Treatment options are still limited, mainly due to insufficient understanding of the underlying ...pathophysiology. Further research and the development of reliable animal models resembling the human disease phenotype is therefore necessary to develop novel, innovative and ideally causal therapies. Since ischaemic heart failure (IHF) is a major cause for AF in patients we investigated AF in the context of IHF in a close-to-human porcine ischaemia-reperfusion model. Myocardial infarction (AMI) was induced in propofol/fentanyl/midazolam-anaesthetized pigs by occluding the left anterior descending artery for 90 minutes to model ischaemia with reperfusion. After 30 days ejection fraction (EF) was significantly reduced and haemodynamic parameters (pulmonary capillary wedge pressure (PCWP), right atrial pressure (RAP), left ventricular enddiastolic pressure (LVEDP)) were significantly elevated compared to age/weight matched control pigs without AMI, demonstrating an IHF phenotype. Electrophysiological properties (sinus node recovery time (SNRT), atrial/AV nodal refractory periods (AERP, AVERP)) did not differ between groups. Atrial burst pacing at 1200 bpm, however, revealed a significantly higher inducibility of atrial arrhythmia episodes including AF in IHF pigs (3/15 vs. 10/16, p = 0.029). Histological analysis showed pronounced left atrial and left ventricular fibrosis demonstrating a structural substrate underlying the increased arrhythmogenicity. Consequently, selective ventricular infarction via LAD occlusion causes haemodynamic alterations inducing structural atrial remodeling which results in increased atrial fibrosis as the arrhythmogenic atrial substrate in pigs with IHF.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The approval of an entirely subcutaneous implantable-cardioverter defibrillator (ICD) system (S-ICD) has raised attention about this promising technology. It was developed to overcome lead failure ...and infection problems of conventional transvenous ICD systems. Nevertheless, lead migration of the initial design and inappropriate shock rates have raised concerns regarding its reliability and safety.
The purpose of this study was to report the largest multicenter series to date of patients with the new device in comparison with a matched conventional transvenous ICD collective with focus on perioperative complications, conversion of induced ventricular fibrillation (VF), and short-term follow-up.
Sixty-nine patients (50 male and 19 female; mean age 45.7 ± 15.7 years) received an S-ICD in three German centers and were randomly assigned to 69 sex- and age-matched conventional ICD patients. The indication was primary prevention in 41 patients (59.4%) without difference between groups (34 control patients; P = .268). The predominant underlying heart disease was ischemic cardiomyopathy in 11 (15.9%), dilated cardiomyopathy in 25 (36.2%), and hypertrophic cardiomyopathy in 10 (14.5%) in the S-ICD group. Mean implantation time was 70.8 ± 27.9 minutes (P = .398). Conversion rates of induced VF were 89.5% for 65 J (15-J safety margin) and 95.5% including reversed shock polarity (15-J safety margin) in the study group. Termination of induced VF was successful in 90.8% (10-J safety margin, device dependent) of the control patients (P = .815). Procedural complications were similar between the 2 groups. Mean follow-up was 217 ± 138 days. During follow-up, 3 patients with S-ICD were appropriately treated for ventricular arrhythmias. Three inappropriate episodes (5.2%) occurred in 3 S-ICD patients due to T-wave oversensing, whereas atrial fibrillation with rapid conduction was the predominant reason for inappropriate therapy in conventional devices (P = .745).
The novel S-ICD system can be implanted safely with similar perioperative adverse events compared with standard transvenous devices. Our case-control study demonstrates a 10.4% failure of conversion of induced VF with the S-ICD set to standard polarity and 15-J safety margin and comparable inappropriate shock rates during short-term follow-up.