Background
Myocardial phantom studies are widely used as a tool to accurately assess the physical phenomenon of dual-isotope simultaneous acquisition (DISA) in the small-animal fields. However, the ...previous phantom did not reproduce the structures of rats or mice. The aim of this study was to develop a novel myocardial phantom simulating the structure of a small animal that can be evaluated using the image quality of DISA.
Methods
A novel small-animal myocardial phantom that simulated a rat was constructed by the myocardium, liver, lung, spine, and torso. Normal and inferior wall defect myocardial phantoms were filled with
99m
Tc or
18
F solution to simulate single-isotope acquisition (SIA) and DISA. Phantom and small-animal images with no scatter correction (nonSC) and scatter correction (SC) were created.
Results
The
99m
Tc DISA with SC showed a low %CV compared to that with nonSC. Although the
99m
Tc DISA with nonSC had lower cavity contrast than that of
99m
Tc SIA with nonSC, the cavity contrast of SC had similar values between SIA and DISA. The minimum %uptake of
99m
Tc SIA with nonSC was a lower value compared to that of
99m
Tc DISA with nonSC. The
99m
Tc DISA was equivalent to the minimum %uptake of
99m
Tc SIA by SC.
Conclusion
We have developed a novel myocardial phantom for the rat model to evaluate the image quality for reproducing the physical phenomenon associated with radiation attenuation and scattering. Furthermore, we could demonstrate the usefulness of the novel small-animal myocardial phantom by image quality evaluation of DISA with
99m
Tc and
18
F compared to SIA.
Full text
Available for:
EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
Antibody titers against SARS-CoV-2 slowly wane over time. Here, we examined how time affects antibody potency. To assess the impact of antibody maturation on durable neutralizing activity against ...original SARS-CoV-2 and emerging variants of concern (VOCs), we analyzed receptor binding domain (RBD)-specific IgG antibodies in convalescent plasma taken 1–10 months after SARS-CoV-2 infection. Longitudinal evaluation of total RBD IgG and neutralizing antibody revealed declining total antibody titers but improved neutralization potency per antibody to original SARS-CoV-2, indicative of antibody response maturation. Neutralization assays with authentic viruses revealed that early antibodies capable of neutralizing original SARS-CoV-2 had limited reactivity toward B.1.351 (501Y.V2) and P.1 (501Y.V3) variants. Antibodies from late convalescents exhibited increased neutralization potency to VOCs, suggesting persistence of cross-neutralizing antibodies in plasma. Thus, maturation of the antibody response to SARS-CoV-2 potentiates cross-neutralizing ability to circulating variants, suggesting that declining antibody titers may not be indicative of declining protection.
Display omitted
•Qualitative changes in plasma neutralizing antibody are longitudinally analyzed•Affinity-matured antibodies with resistance to variants are durably maintained•Neutralizing potency and breadth to SARS-CoV-2 variants increase with time•Serological immunity evolves with time to counter SARS-CoV-2 variants
Antigenic drifts in SARS-CoV-2 variants permit escape from neutralizing antibody in COVID-19 convalescent plasma. Moriyama et al. reveal the evolution of serological immunity with time that counters SARS-CoV-2 variants via affinity maturation and durable elicitation of IgG antibodies that are resistant to viral escape.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
To determine virus shedding duration, we examined clinical samples collected from the upper respiratory tracts of persons infected with severe acute respiratory syndrome coronavirus 2 Omicron variant ...in Japan during November 29-December 18, 2021. Vaccinees with mild or asymptomatic infection shed infectious virus 6-9 days after onset or diagnosis, even after symptom resolution.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, ODKLJ, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
This study presents a stress testing operation conducted using a wireline formation tester in a newly discovered gas hydrate prospect located offshore in Japan. The campaign, which spanned from ...December 2021 to January 2022, involved drilling a well using logging-while-drilling technology. Subsequently, wireline formation testing and stress testing were successfully conducted at three different depths within a gas hydrate-concentrated zone. The testing was accomplished in a single riserless descent, with the primary goal of obtaining crucial data such as mobility, formation pressure, and fracture gradient for one of the prospects. This operation marked the first stress testing job performed with dual packers in an open water and deepwater environment specifically for gas hydrate reservoirs. The study also provides a comprehensive interpretation of the data gathered during the operation. Moreover, it evaluates various properties such as formation mobility, formation pressure, initial breakdown pressure, closure pressure, fracture propagation pressure, and instantaneous shut-in pressure.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
Quantitative measurement of SARS-CoV-2 neutralizing antibodies is highly expected to evaluate immune status, vaccine response, and antiviral therapy. The Elecsys® Anti-SARS-CoV-2 S (Elecsys® anti-S) ...was developed to measure anti-SARS-CoV-2 S proteins. We sought to investigate whether Elecsys® anti-S can be used to predict neutralizing activities in patients' serums using an authentic virus neutralization assay. One hundred forty-six serum samples were obtained from 59 patients with COVID-19 at multiple time points. Of the 59 patients, 44 cases were included in Group M (mild 23, moderate 21) and produced 84 samples (mild 35, moderate 49), while 15 cases were included in Group S (severe 11, critical 4) and produced 62 samples (severe 43, critical 19). The neutralization assay detected 73% positive cases, and Elecsys® anti-S and Elecsys® Anti-SARS-CoV-2 (Elecsys® anti-N) showed 72% and 66% positive cases, respectively. A linear correlation between the Elecsys® anti-S assay and the neutralization assay were highly correlated (r = 0.7253, r.sup.2 = 0.5261) than a linear correlation between the Elecsys® anti-N and neutralization assay (r = 0.5824, r.sup.2 = 0.3392). The levels of Elecsys® anti-S antibody and neutralizing activities were significantly higher in Group S than in Group M after 6 weeks from onset of symptoms (p < 0.05). Conversely, the levels of Elecsys® anti-N were comparable in both groups. Three immunosuppressed patients, including cancer patients, showed low levels of anti-S and anti-N antibodies and neutralizing activities throughout the measurement period, indicating the need for careful follow-up. Our data indicate that Elecsys® anti-S can predict the neutralization antibodies in COVID-19.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Kawasaki disease (KD) is an acute, febrile, systemic vasculitis of unknown etiology that primarily affects the coronary arteries and generally occurs at around 1 year of age. Although the diagnosis ...of KD is generally not difficult, it is challenging in cases of incomplete KD lacking characteristic clinical manifestations. The incidence of incomplete KD is higher in infants younger than 6 months of age. Pneumonia is an extremely rare complication of KD and can be misinterpreted as atypical pneumonia rather than KD. Herein, we report a neonate with atypical KD and severe pneumonia who required mechanical ventilation.
Japanese one-month-old infant had only fever and rash on admission (day 1), and he was transferred to the intensive care unit for severe pneumonia on day 2. Although pneumonia improved following intensive care, he was diagnosed with KD on day 14 because of emerging typical clinical manifestations such as fever, bulbar nonexudative conjunctival injection, desquamation of the fingers, and coronary artery aneurysm. KD symptoms improved after three doses of intravenous immunoglobulin plus cyclosporine. However, small coronary aneurysms were present at the time of discharge. In a retrospective analysis, no pathogens were detected by multiplex real-time PCR in samples collected at admission, and the serum cytokine profile demonstrated prominent elevation of IL-6 as well as elevation of neopterin, sTNF-RI, and sTNF-RII, which suggested KD.
The patient's entire clinical course, including the severe pneumonia, was caused by KD. As in this case, neonatal KD may exhibit atypical manifestations such as severe pneumonia requiring mechanical ventilation.
Postmortem lung pathology of a patient in Japan with severe acute respiratory syndrome coronavirus 2 infection showed diffuse alveolar damage as well as bronchopneumonia caused by Streptococcus ...pneumoniae infection. The distribution of each pathogen and the accompanying histopathology suggested the infections progressed in a mutually exclusive manner within the lung, resulting in fatal respiratory failure.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, ODKLJ, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The COVID-19 antibody test was developed to investigate the humoral immune response to SARS-CoV-2 infection. In this study, we examined whether S antibody titers measured using the anti-SARS-CoV-2 ...IgG II Quant assay (S-IgG), a high-throughput test method, reflects the neutralizing capacity acquired after SARS-CoV-2 infection or vaccination. To assess the antibody dynamics and neutralizing potency, we utilized a total of 457 serum samples from 253 individuals: 325 samples from 128 COVID-19 patients including 136 samples from 29 severe/critical cases (Group S), 155 samples from 71 mild/moderate cases (Group M), and 132 samples from 132 health care workers (HCWs) who have received 2 doses of the BNT162b2 vaccinations. The authentic virus neutralization assay, the surrogate virus neutralizing antibody test (sVNT), and the Anti-N SARS-CoV-2 IgG assay (N-IgG) have been performed along with the S-IgG. The S-IgG correlated well with the neutralizing activity detected by the authentic virus neutralization assay (0.8904. of Spearman's rho value, p < 0.0001) and sVNT (0.9206. of Spearman's rho value, p < 0.0001). However, 4 samples (2.3%) of S-IgG and 8 samples (4.5%) of sVNT were inconsistent with negative results for neutralizing activity of the authentic virus neutralization assay. The kinetics of the SARS-CoV-2 neutralizing antibodies and anti-S IgG in severe cases were faster than the mild cases. All the HCWs elicited anti-S IgG titer after the second vaccination. However, the HCWs with history of COVID-19 or positive N-IgG elicited higher anti-S IgG titers than those who did not have it previously. Furthermore, it is difficult to predict the risk of breakthrough infection from anti-S IgG or sVNT antibody titers in HCWs after the second vaccination. Our data shows that the use of anti-S IgG titers as direct quantitative markers of neutralizing capacity is limited. Thus, antibody tests should be carefully interpreted when used as serological markers for diagnosis, treatment, and prophylaxis of COVID-19.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Quantitative measurement of SARS-CoV-2 neutralizing antibodies is highly expected to evaluate immune status, vaccine response, and antiviral therapy. The Elecsys® Anti-SARS-CoV-2 S (Elecsys® anti-S) ...was developed to measure anti-SARS-CoV-2 S proteins. We sought to investigate whether Elecsys® anti-S can be used to predict neutralizing activities in patients' serums using an authentic virus neutralization assay. One hundred forty-six serum samples were obtained from 59 patients with COVID-19 at multiple time points. Of the 59 patients, 44 cases were included in Group M (mild 23, moderate 21) and produced 84 samples (mild 35, moderate 49), while 15 cases were included in Group S (severe 11, critical 4) and produced 62 samples (severe 43, critical 19). The neutralization assay detected 73% positive cases, and Elecsys® anti-S and Elecsys® Anti-SARS-CoV-2 (Elecsys® anti-N) showed 72% and 66% positive cases, respectively. A linear correlation between the Elecsys® anti-S assay and the neutralization assay were highly correlated (r = 0.7253, r2 = 0.5261) than a linear correlation between the Elecsys® anti-N and neutralization assay (r = 0.5824, r2 = 0.3392). The levels of Elecsys® anti-S antibody and neutralizing activities were significantly higher in Group S than in Group M after 6 weeks from onset of symptoms (p < 0.05). Conversely, the levels of Elecsys® anti-N were comparable in both groups. Three immunosuppressed patients, including cancer patients, showed low levels of anti-S and anti-N antibodies and neutralizing activities throughout the measurement period, indicating the need for careful follow-up. Our data indicate that Elecsys® anti-S can predict the neutralization antibodies in COVID-19.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
COVID-19 antibody testing has been developed to investigate humoral immune response in SARS-CoV-2 infection. To assess the serological dynamics and neutralizing potency following SARS-CoV-2 ...infection, we investigated the neutralizing (NT) antibody, anti-spike, and anti-nucleocapsid antibodies responses using a total of 168 samples obtained from 68 SARS-CoV-2 infected patients. Antibodies were measured using an authentic virus neutralization assay, the high-throughput laboratory measurements of the Abbott Alinity quantitative anti-spike receptor-binding domain IgG (S-IgG), semiquantitative anti-spike IgM (S-IgM), and anti-nucleocapsid IgG (N-IgG) assays. The quantitative measurement of S-IgG antibodies was well correlated with the neutralizing activity detected by the neutralization assay (r = 0.8943, p < 0.0001). However, the kinetics of the SARS-CoV-2 NT antibody in severe cases were slower than that of anti-S and anti-N specific antibodies. These findings indicate a limitation of using the S-IgG antibody titer, detected by the chemiluminescent immunoassay, as a direct quantitative marker of neutralizing activity capacity. Antibody testing should be carefully interpreted when utilized as a marker for serological responses to facilitate diagnostic, therapeutic, and prophylactic interventions.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK