Background
The gonio-endoscope is a novel device for use during minimally invasive glaucoma surgery (MIGS) to treat glaucomatous eyes with cloudy cornea. The MIGS procedure requires a surgical ...gonioprism lens for direct visualization of the angle, intraoperative manipulation of the surgical microscope and the patient’s head position, and the patient’s eye without a cloudy cornea. In cases with cloudy corneas or limitation of neck movement, MIGS cannot be safely performed. Gonio-endoscopy facilitates clear visualization of the trabecular meshwork (TM) to perform MIGS safely and easily even in a patient with corneal opacities or limitation of neck movement with no additional MIGS procedures. We report the first case in which we performed the newly developed a 10,000-pixel high-resolution 23-gauge gonio-endoscopic operation.
Case presentation
The patient was a 58-year-old man with Down syndrome who had secondary glaucoma bilaterally after cataract surgery and long-time use of a steroid for atopic dermatitis and allergic conjunctivitis. His left eye had a cloudy cornea after penetrating keratoplasty for keratoconus with severe corneal residual scarring after prior resolved corneal hydrops. When the intraocular pressure (IOP) in his left eye increased to 41 mmHg despite the maximum use of anti-glaucoma eyedrops, he was referred to our hospital. Anterior-segment optical coherence tomography showed an open angle. We developed a new gonio-endoscope (MACHIDA Endoscope Co., Ltd., Chiba, Japan and NIPRO CORPORATION, Osaka, Japan), the probe of which is bent appropriately to aid visualization of and access to the TM. After obtaining clinical approval from the government and our institution, we could safely perform a high-resolution 23-gauge gonio-endoscopy-assisted microhook ab interno trabeculotomy (μLOT). The IOP decreased to 10 mmHg and the visual acuity has been preserved with no major complications for 1 year postoperatively.
Conclusion
This new technique of clear gonio-visualization using a gonio-endoscope might be helpful for a safe and easy μLOT in patients with cloudy corneas. This device can apply to other types of MIGS procedures and cases with pathological diagnoses of glaucoma that are difficult to treat.
We are pleased to bring you the 5th edition of the Glaucoma Clinical Practice Guidelines. Clinical practice guidelines are based on evidence (scientific grounds). It is a document that presents the ...treatment that is the most appropriate for the patient. "Glaucoma Clinical Guidelines" was first published in 2003. This was the first guideline for glaucoma treatment in Japan. The principle of glaucoma treatment is to lower intraocular pressure. Means for lowering intraocular pressure includes drugs, lasers, and surgery; Glaucoma is a disease that should be considered as a complex syndrome rather than a single condition. Therefore, the actual medical treatment is not as simple as one word. This time we set the Clinical Questionnaire with a focus on glaucoma treatment. We hope that you will take advantage of the 5th edition.
Full text
Available for:
EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
Iris mammillation is a rare disease characterized by the distribution of multiple nodules on the iris surface. The course of uveitic glaucoma with iris mammillation has never been reported.
A ...56-year-old woman, who presented with unilateral decreased vision, visited our hospital for treatment of uveitic glaucoma in the right eye. Multiple nodules were scattered over the iris surface in that eye. This case was diagnosed as iris mammillation on clinical findings. After excluding malignant tumors such as melanoma, trabeculectomy was performed. The resected iris had no pathologically malignant findings. The iris nodules evolved to a sand-like appearance, and the intraocular pressure remained stable without recurrent inflammation 7 years after trabeculectomy.
In a case of unilateral uveitic glaucoma with iris mammillation, filtration surgery was performed after excluding the presence of a malignancy, and the long-term postoperative course has been stable.
The needle revision procedure to address failing filtering blebs is a blind technique that might easily damage the scleral flap, conjunctiva, and choroid. We propose a new surgical procedure, ...infrared monitor-guided bleb revision, to perform bleb revision minimally invasively and effectively, and demonstrate the procedure in a patient. We developed the guided procedure with the infrared monitor to observe the bleb interior with greater contrast. Under the monitor, we dissect the hard fibrotic tissue with a bleb knife and, if necessary, remove adhesions using a needle and vitreous forceps. Finally, 5-fluorouracil is injected into the subconjunctiva. We have performed bleb revisions safely with clear visualization of the scleral flap using an infrared light. In the current case, the patient had good intraocular pressure control for about 1 year. The new infrared monitor-guided bleb revision procedure facilitates successful bleb revisions without damage to the underlying structures.
Toxic anterior segment syndrome (TASS) is a rapid-onset inflammation of the eye following uneventful ocular surgery. We report a case of TASS following Baerveldt glaucoma implant (BGI) surgery. ...Inductively coupled plasma-mass spectrometry (ICP-MS) identified barium in the eye and in the eluate from the bleb of the BGI. We attribute TASS in our patient to the dissolution of barium from the BGI and its entry into the eye, where it causes severe inflammation.
Full text
Available for:
NUK, OILJ, SAZU, UKNU, UL, UM, UPUK
To report findings on the tilt angle of optic nerve heads (ONHs) that developed intrapapillary hemorrhage with adjacent peripapillary subretinal hemorrhage (IHAPSH) using swept-source optical ...coherence tomography (SS-OCT).
Five consecutive patients who presented with IHAPSH were reviewed retrospectively. We reviewed five consecutive eyes from the five patients, analyzed the optic tilt angle obtained from SS-OCT B-scans, and compared the results and other clinical characteristics. All patients had larger optic disc tilt angles in the eyes with IHAPSH than in the contralateral, unaffected eye. The mean ratio of the tilt angle in the eyes with IHAPSH to that in the contralateral eye was 1.37 (95% confidence interval 1.15–1.58).
The ONH of IHAPSH was evaluated quantitatively with SS-OCT for the first time in this study. Larger angle tilted discs in IHAPSH-affected eyes are anatomically and histologically more vulnerable and may explain why IHAPSH develops monocularly.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
In vertebrates, retinal neural circuitry for visual perception is organized in specific layers. The outer plexiform layer is the first synaptic region in the visual pathway, where photoreceptor ...synaptic terminals connect with bipolar and horizontal cell processes. However, molecular mechanisms underlying cone synapse formation to mediate OFF pathways remain unknown. This study reveals that Necl-1/CADM3 is localized at S- and S/M-opsin-containing cones and dendrites of type 4 OFF cone bipolar cells (CBCs). In Necl-1−/− mouse retina, synapses between cones and type 4 OFF CBCs were dislocated, horizontal cell distribution became abnormal, and α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid (AMPA) receptors were dislocated. Necl-1−/− mice exhibited aberrant short-wavelength-light-elicited signal transmission from cones to OFF CBCs, which was rescued by AMPA receptor potentiator. Additionally, Necl-1−/− mice showed impaired optokinetic responses. These findings suggest that Necl-1 regulates cone synapse formation to mediate OFF cone pathways elicited by short-wavelength light in mouse retina.
Display omitted
•Necl-1 is essential for correct cone synapse location•Necl-1 regulates short-wavelength-light-sensitive OFF cone pathways•Necl-1 is required for normal visual function in mouse retina
Biological sciences; Molecular neuroscience; Neuroscience
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
We report a case in which intraocular endoscopy clarified the cause of Ahmed glaucoma valve (AGV) failure with a cloudy cornea. A 42-year-old patient with glaucoma underwent AGV implant surgery to ...treat secondary glaucoma due to chronic iridocyclitis in his left eye. After AGV, he developed bullous keratopathy (BK) in that eye. After Descemet stripping automated endothelial keratoplasty (DSAEK) was performed to treat BK, the intraocular pressure (IOP) increased and early failure of the DSAEK resulted again in a cloudy cornea. We could not precisely detect any cause of AGV failure with ordinary imaging instrumentation. An intraocular endoscope was used to determine that cause, and we found that the fibrous tissue occluded the tube of the AGV. The IOP decreased soon after the tissue was removed. We conclude that intraocular endoscopy was useful for diagnosing AGV failure with BK.
To compare early-stage intrableb structural changes after Ex-PRESS surgery using anterior-segment optical coherence tomography between primary open-angle glaucoma (POAG) and exfoliation glaucoma ...(XFG).
Twenty-five POAG eyes and 15 XFG eyes that underwent Ex-PRESS surgery were evaluated. Intrableb images were classified into four categories based on previously reported scattering intensity: high-, medium-, and low-scattering walls and fluid-filled spaces. Bleb measurements were evaluated in both groups throughout 6 postoperative months. The 3-year surgical success was defined by the criteria intraocular pressure (IOP) < 18 mmHg and IOP < 15 mmHg with or without medications.
The fluid-filled space volume at 3 and 6 months (P = 0.005 and P = 0.022, respectively) and the volume ratio of the low-scattering wall to the bleb wall (P = 0.028) at 6 months were significantly smaller in XFG than POAG postoperatively. The volume ratio of the high-scattering wall to the bleb wall was correlated positively (P = 0.007) with the IOP, and that of the low-scattering wall to the bleb wall was correlated negatively (P = 0.002) with the IOP in XFG. The 3-year surgical success rates for both criteria were significantly lower in XFG than POAG.
Fluid-filled spaces were smaller in XFG than in POAG after Ex-PRESS surgery. The proportion of the high-scattering wall tended to increase and the low-scattering wall tended to decrease in XFG eyes with high IOP. Early-stage intrableb structural changes differed between POAG and XFG and may affect the prognosis.
Our cutting-edge observation of intrableb fibrosis can be an important predictor of the surgical outcome.
Purpose
We compared the 1-year surgical outcomes of microhook ab interno trabeculotomy (μLOT) using three types of microhooks.
Methods
We retrospectively analyzed 81 eyes that underwent μLOT, in ...which three microhooks, the Sinskey hook, Tanito Micro-Hook-trabeculotomy-device (TMH), and Matsushita ed. TMH, were used. We collected the data from the medical records. We analyzed the success rates and risk factors. Failure was defined as the need for additional surgery for IOP reduction, loss of light perception, and IOP ≧22 mmHg and IOP reduction <20% (definition 1), IOP ≧17 mmHg and IOP reduction <20% (definition 2), IOP ≧15 mmHg and IOP reduction <25% (definition 3), or IOP ≧12 mmHg and IOP reduction <30% (definition 4) at two consecutive follow-up visits.
Results
Twenty-six eyes underwent μLOT using the Sinskey microhook (group S), 21 eyes using the TMH (group T), and 34 eyes using the Matsushita ed. TMH (group M). The mean postoperative IOP and IOP-lowering medication score decreased significantly. The respective success rates among groups S, T, and M did not differ significantly (definition 1, 65.4%, 61.9%, and 55.9%; definition 2, 42.3%, 47.6%, and 32.3%; definition 3, 15.4%, 28.6%, and 23.5%; definition 4, 0%, 9.5%, and 2.9%). In group S, the hyphema-related IOP spikes decreased within 2 weeks postoperatively, and in group M, the non-hyphema-related IOP spikes decreased significantly.
Conclusion
The 1-year surgical outcomes and complications after μLOT did not differ significantly among the three microhooks. The differences in the microhook tips might be associated with postoperative transient IOP spikes.
Full text