Akademska digitalna zbirka SLovenije - logo

Search results

Basic search    Expert search   

Currently you are NOT authorised to access e-resources SI consortium. For full access, REGISTER.

1 2 3 4 5
hits: 157
1.
Full text
Available for: GEOZS, OILJ, UPUK

PDF
2.
  • AAPM TG 158: Measurement an... AAPM TG 158: Measurement and calculation of doses outside the treated volume from external‐beam radiation therapy
    Kry, Stephen F.; Bednarz, Bryan; Howell, Rebecca M. ... Medical physics (Lancaster), October 2017, Volume: 44, Issue: 10
    Journal Article
    Peer reviewed
    Open access

    The introduction of advanced techniques and technology in radiotherapy has greatly improved our ability to deliver highly conformal tumor doses while minimizing the dose to adjacent organs at risk. ...
Full text
Available for: BFBNIB, FZAB, GIS, IJS, KILJ, NLZOH, NUK, OILJ, SAZU, SBCE, SBMB, UL, UM, UPUK

PDF
3.
  • Proportion of second cancer... Proportion of second cancers attributable to radiotherapy treatment in adults: a cohort study in the US SEER cancer registries
    de Gonzalez, Amy Berrington, Dr; Curtis, Rochelle E, MA; Kry, Stephen F, PhD ... The lancet oncology, 04/2011, Volume: 12, Issue: 4
    Journal Article
    Peer reviewed
    Open access

    Summary Background Improvements in cancer survival have made the long-term risks from treatments more important, including the risk of developing a second cancer after radiotherapy. We aimed to ...
Full text
Available for: GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK

PDF
4.
  • AAPM TG 191: Clinical use o... AAPM TG 191: Clinical use of luminescent dosimeters: TLDs and OSLDs
    Kry, Stephen F.; Alvarez, Paola; Cygler, Joanna E. ... Medical physics (Lancaster), February 2020, Volume: 47, Issue: 2
    Journal Article
    Peer reviewed

    Thermoluminescent dosimeters (TLD) and optically stimulated luminescent dosimeters (OSLD) are practical, accurate, and precise tools for point dosimetry in medical physics applications. The charges ...
Full text
Available for: BFBNIB, FZAB, GIS, IJS, KILJ, NLZOH, NUK, OILJ, SAZU, SBCE, SBMB, UL, UM, UPUK

PDF
5.
  • Material matters: Analysis ... Material matters: Analysis of density uncertainty in 3D printing and its consequences for radiation oncology
    Craft, Daniel F.; Kry, Stephen F.; Balter, Peter ... Medical physics (Lancaster), April 2018, Volume: 45, Issue: 4
    Journal Article
    Peer reviewed

    Purpose Using 3D printing to fabricate patient‐specific devices such as tissue compensators, boluses, and phantoms is inexpensive and relatively simple. However, most 3D printing materials have not ...
Full text
Available for: BFBNIB, FZAB, GIS, IJS, KILJ, NLZOH, NUK, OILJ, SAZU, SBCE, SBMB, UL, UM, UPUK
6.
  • Report of AAPM Task Group 2... Report of AAPM Task Group 219 on independent calculation‐based dose/MU verification for IMRT
    Zhu, Timothy C.; Stathakis, Sotiris; Clark, Jennifer R. ... Medical physics (Lancaster), October 2021, Volume: 48, Issue: 10
    Journal Article
    Peer reviewed
    Open access

    Independent verification of the dose per monitor unit (MU) to deliver the prescribed dose to a patient has been a mainstay of radiation oncology quality assurance (QA). We discuss the role of ...
Full text
Available for: BFBNIB, FZAB, GIS, IJS, KILJ, NLZOH, NUK, OILJ, SAZU, SBCE, SBMB, UL, UM, UPUK

PDF
7.
  • Independent recalculation o... Independent recalculation outperforms traditional measurement‐based IMRT QA methods in detecting unacceptable plans
    Kry, Stephen F.; Glenn, Mallory C.; Peterson, Christine B. ... Medical physics (Lancaster), August 2019, Volume: 46, Issue: 8
    Journal Article
    Peer reviewed
    Open access

    Purpose To evaluate the performance of an independent recalculation and compare it against current measurement‐based patient specific intensity‐modulated radiation therapy (IMRT) quality assurance ...
Full text
Available for: BFBNIB, FZAB, GIS, IJS, KILJ, NLZOH, NUK, OILJ, SAZU, SBCE, SBMB, UL, UM, UPUK

PDF
8.
  • Organ at risk delineation f... Organ at risk delineation for radiation therapy clinical trials: Global Harmonization Group consensus guidelines
    Mir, Romaana; Kelly, Sarah M.; Xiao, Ying ... Radiotherapy and oncology, September 2020, 2020-09-00, Volume: 150
    Journal Article
    Peer reviewed
    Open access

    •The GHG identified an unmet need for standardized OAR contouring guidance.•AAPM TG 263 recommendations exist for all but 10 OAR structures.•Here we present consensus guidance on 73 OARs with ...
Full text
Available for: GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP

PDF
9.
  • Management of radiotherapy ... Management of radiotherapy patients with implanted cardiac pacemakers and defibrillators: A Report of the AAPM TG‐203
    Miften, Moyed; Mihailidis, Dimitris; Kry, Stephen F. ... Medical physics (Lancaster), December 2019, 2019-Dec, 2019-12-00, 20191201, Volume: 46, Issue: 12
    Journal Article
    Peer reviewed
    Open access

    Managing radiotherapy patients with implanted cardiac devices (implantable cardiac pacemakers and implantable cardioverter‐defibrillators) has been a great practical and procedural challenge in ...
Full text
Available for: BFBNIB, FZAB, GIS, IJS, KILJ, NLZOH, NUK, OILJ, SAZU, SBCE, SBMB, UL, UM, UPUK

PDF
10.
  • The Value of On-Site Proton Audits
    Taylor, Paige A; Lowenstein, Jessica; Followill, David ... International journal of radiation oncology, biology, physics, 03/2022, Volume: 112, Issue: 4
    Journal Article
    Peer reviewed

    This study aimed to highlight the value and key findings of on-site proton audits. The authors performed 38 on-site measurement-based peer reviews of proton centers participating in National Cancer ...
Full text
Available for: GEOZS, OILJ, UPUK
1 2 3 4 5
hits: 157

Load filters