The calorimeter, range detector and active target elements of the T2K near detectors rely on the Hamamatsu Photonics Multi-Pixel Photon Counters (MPPCs) to detect scintillation light produced by ...charged particles. Detailed measurements of the MPPC gain, afterpulsing, crosstalk, dark noise, and photon detection efficiency for low light levels are reported. In order to account for the impact of the MPPC behavior on T2K physics observables, a simulation program has been developed based on these measurements. The simulation is used to predict the energy resolution of the detector.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
An upgrade of the Near Detector of the T2K long baseline neutrino oscillation experiment, ND280, has been proposed. This upgrade will include two new Time Projection Chambers, each equipped with 16 ...resistive Micromegas modules for gas amplification. A first prototype of resistive Micromegas has been designed, built, installed in the HARP field cage, and exposed to a beam of charged particles at CERN. The data have been used to characterize the performances of the resistive Micromegas module. A spatial resolution of 300 μm and a deposited energy resolution of 9% were observed for horizontal electrons crossing the TPCs at 30 cm from the anode. Such performances fully satisfy the requirements for the upgrade of the ND280 TPC.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
The T2K Side Muon Range Detector (SMRD) Aoki, S.; Barr, G.; Batkiewicz, M. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
01/2013, Volume:
698
Journal Article
Peer reviewed
Open access
The T2K experiment is a long baseline neutrino oscillation experiment aiming to observe the appearance of νe in a νμ beam. The νμ beam is produced at the Japan Proton Accelerator Research Complex ...(J-PARC), observed with the 295km distant Super-Kamiokande Detector and monitored by a suite of near detectors at 280m from the proton target. The near detectors include a magnetized off-axis detector (ND280) which measures the unoscillated neutrino flux and neutrino cross-sections. The present paper describes the outermost component of ND280 which is a Side Muon Range Detector (SMRD) composed of scintillation counters with embedded wavelength shifting fibers and Multi-Pixel Photon Counter readout. The components, performance and response of the SMRD are presented.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
The T2K experiment reports updated measurements of neutrino and antineutrino oscillations using both appearance and disappearance channels. This result comes from an exposure of 14.9 (16.4) × 1020 ...protons on target in neutrino (antineutrino) mode. Significant improvements have been made to the neutrino interaction model and far detector reconstruction. An extensive set of simulated data studies have also been performed to quantify the effect interaction model uncertainties have on the T2K oscillation parameter sensitivity. T2K performs multiple oscillation analyses that present both frequentist and Bayesian intervals for the Pontecorvo-Maki-Nakagawa-Sakata parameters. For fits including a constraint on sin 2θ13 from reactor data and assuming normal mass ordering T2K measures sin 2θ23 = 0.53 +0.03 −0.04 and Δm232 = (2.45 ± 0.07) × 10−3 eV2 c−4. The Bayesian analyses show a weak preference for normal mass ordering (89% posterior probability) and the upper sin 2θ23 octant (80% posterior probability), with a uniform prior probability assumed in both cases. The T2K data exclude CP conservation in neutrino oscillations at the 2σ level.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
The T2K experiment measures muon neutrino disappearance and electron neutrino appearance in accelerator-produced neutrino and antineutrino beams. With an exposure of 14.7(7.6)×1020 protons on target ...in the neutrino (antineutrino) mode, 89 νe candidates and seven anti-νe candidates are observed, while 67.5 and 9.0 are expected for δCP=0 and normal mass ordering. The obtained 2σ confidence interval for the CP-violating phase, δCP, does not include the CP-conserving cases (δCP=0, π). The best-fit values of other parameters are sin2θ23=0.526−0.036+0.032 and Δm322=2.463−0.070+0.071×10−3 eV2/c4.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UL, UM
An analytical model of preamplifier noise identification in a spectrometric system is presented in the article. It allows analysis of normal passive pulse shapers, general time-invariant systems as ...well as time-variant systems. An equivalent noise charge (ENC) is modeled as the sum of three components: (i) proportional to the amplifier shaping time, (ii) inversely proportional, and (iii) independent of the amplifier shaping time. The Least Squares Method for identifying the noise components of the spectrometric system was used; measured values of ENC were fitted to the theoretical dependence on peaking time τ0. Analytical formulas have been derived for the values of coefficients included in the dependence of ENC on the shaping time for CR−(RC)n shaping for any value of n. The conclusion of this analysis may be used for the optimization of spectrometric systems.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
The first measurement of transverse-spin-dependent azimuthal asymmetries in the pion-induced Drell-Yan (DY) process is reported. We use the CERN SPS 190 GeV/c π^{-} beam and a transversely polarized ...ammonia target. Three azimuthal asymmetries giving access to different transverse-momentum-dependent (TMD) parton distribution functions (PDFs) are extracted using dimuon events with invariant mass between 4.3 GeV/c^{2} and 8.5 GeV/c^{2}. Within the experimental uncertainties, the observed sign of the Sivers asymmetry is found to be consistent with the fundamental prediction of quantum chromodynamics (QCD) that the Sivers TMD PDFs extracted from DY have a sign opposite to the one extracted from semi-inclusive deep-inelastic scattering (SIDIS) data. We present two other asymmetries originating from the pion Boer-Mulders TMD PDFs convoluted with either the nucleon transversity or pretzelosity TMD PDFs. A recent COMPASS SIDIS measurement was obtained at a hard scale comparable to that of these DY results. This opens the way for possible tests of fundamental QCD universality predictions.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
We report on the first measurement of exclusive single-photon muoproduction on the proton by COMPASS using 160GeV/c polarised μ+ and μ− beams of the CERN SPS impinging on a liquid hydrogen target. We ...determine the dependence of the average of the measured μ+ and μ− cross sections for deeply virtual Compton scattering on the squared four-momentum transfer t from the initial to the final proton. The slope B of the t-dependence is fitted with a single exponential function, which yields B=(4.3±0.6stat|sys−0.3+0.1)(GeV/c)−2. This result can be converted into a transverse extension of partons in the proton, 〈r⊥2〉=(0.58±0.04stat|sys−0.02+0.01±0.04model)fm. For this measurement, the average virtuality of the photon mediating the interaction is 〈Q2〉=1.8(GeV/c)2 and the average value of the Bjorken variable is 〈xBj〉=0.056.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
ECAL0 is a new electromagnetic calorimeter designed for studying generalized parton distributions at the COMPASS II experiment at CERN. It will be located next to the target and will cover larger ...photon angles (up to 30 degrees). It is a modular high-granularity Shashlyk device with total number of individual channels of approx. 1700 and readout based on wavelength shifting fibers and micropixel avalanche photodiodes. Characterization of the calorimeter includes tests of particular sub-components, tests of complete modules and module arrays, as well as a pilot run of a fully-functional, quarter-size prototype in the COMPASS experiment. The main goals of the tests on low-intensity electron beam at the ELSA accelerator in Bonn were: to provide energy calibration using electrons, to measure angular response of the calorimeter and to perform an energy scan to cross-check previously collected data. A dedicated measurement setup was prepared for the tests, including a 3x3 array of the ECAL0 modules, a scintillating-fibre hodoscope and a remotely-controlled motorized movable platform. The measurements were performed using three electron energies: 3.2 GeV, 1.6 GeV and 0.8 GeV. They include a calibration of the whole detector array with a straight beam and multiple angular scans.
We have performed the most comprehensive resonance-model fit of π−π−π+ states using the results of our previously published partial-wave analysis (PWA) of a large data set of diffractive-dissociation ...events from the reaction π−+p→π−π−π++precoil with a 190 GeV/c pion beam. The PWA results, which were obtained in 100 bins of three-pion mass, 0.5<m3π<2.5 GeV/c2, and simultaneously in 11 bins of the reduced four-momentum transfer squared, 0.1<t′<1.0 (GeV/c)2, are subjected to a resonance-model fit using Breit-Wigner amplitudes to simultaneously describe a subset of 14 selected waves using 11 isovector light-meson states with JPC=0−+, 1++, 2++, 2−+, 4++, and spin-exotic 1−+ quantum numbers. The model contains the well-known resonances π(1800), a1(1260), a2(1320), π2(1670), π2(1880), and a4(2040). In addition, it includes the disputed π1(1600), the excited states a1(1640), a2(1700), and π2(2005), as well as the resonancelike a1(1420). We measure the resonance parameters mass and width of these objects by combining the information from the PWA results obtained in the 11 t′ bins. We extract the relative branching fractions of the ρ(770)π and f2(1270)π decays of a2(1320) and a4(2040), where the former one is measured for the first time. In a novel approach, we extract the t′ dependence of the intensity of the resonances and of their phases. The t′ dependence of the intensities of most resonances differs distinctly from the t′ dependence of the nonresonant components. For the first time, we determine the t′ dependence of the phases of the production amplitudes and confirm that the production mechanism of the Pomeron exchange is common to all resonances. We have performed extensive systematic studies on the model dependence and correlations of the measured physical parameters.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM