This letter gathers a selection of Standard Model predictions issued from the metrology of the CKM parameters performed by the CKMfitter group. The selection includes purely leptonic decays of ...neutral and charged B, D and K mesons. In the light of the expected measurements from the LHCb experiment, a special attention is given to the radiative decay modes of B mesons as well as to the B-meson mixing observables, in particular the semileptonic charge asymmetries a^d,s_SL which have been recently investigated by the D0 experiment at Tevatron. Constraints arising from rare kaon decays are addressed, in light of both current results and expected performances of future rare kaon experiments. All results have been obtained with the CKMfitter analysis package, featuring the frequentist statistical approach and using Rfit to handle theoretical uncertainties.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
For the High-Luminosity Upgrade of the Large Hadron Collider at CERN, the ATLAS Inner Detector will be replaced with a new, all-silicon tracker (ITk). In order to minimise the amount of material in ...the ITk, circuit boards with readout electronics will be glued onto the active area of the sensor. Several adhesives, investigated to be used for the construction of detector modules, were found to become fluorescent when exposed to UV light. These adhesives could become a light source in the high-radiation environment of the ATLAS detector. The effect of fluorescent material covering the sensor surface in a high-radiation environment has been studied for a silicon micro-strip sensor using a micro-focused X-ray beam. By positioning the beam parallel to the sensor surface and pointing it both inside the sensor and above the sensor surface inside the deposited glue, the sensor responses from direct hits and fluorescence can be compared with high precision. This contribution presents a setup to study the susceptibility of silicon strip sensors to light contamination from fluorescent materials and shows their impact on the noise and fake signal rate of a sensor operated in a high-radiation environment.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
For the High-Luminosity Upgrade of the Large Hadron Collider at CERN, the ATLAS Inner Detector will be replaced with a new, all-silicon tracker (ITk). In order to minimise the amount of material in ...the ITk, circuit boards with readout electronics will be glued onto the active area of the sensor. Several adhesives, investigated to be used for the construction of detector modules, were found to become fluorescent when exposed to UV light. These adhesives could become a light source in the high-radiation environment of the ATLAS detector. The effect of fluorescent material covering the sensor surface in a high-radiation environment has been studied for a silicon micro-strip sensor using a micro-focused X-ray beam. By positioning the beam parallel to the sensor surface and pointing it both inside the sensor and above the sensor surface inside the deposited glue, the sensor responses from direct hits and fluorescence can be compared with high precision. This contribution presents a setup to study the susceptibility of silicon strip sensors to light contamination from fluorescent materials and shows their impact on the noise and fake signal rate of a sensor operated in a high-radiation environment.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
We perform model-independent statistical analyses of three scenarios accommodating new physics (NP) in Delta F = 2 flavor-changing neutral current amplitudes. In a scenario in which NP in B sub(d) - ...B sub(d) mixing and B sub(s) - B sub(s) mixing is uncorrelated, we find the parameter point representing the standard model disfavored by 2.4 standard deviations. However, recent LHCb data on B sub(s) neutral meson mixing forbid a good accommodation of the DO data on the semileptonic CP asymmetry A sub(SL). We introduce a fourth scenario with NP in both (ProQuest: Formulae and/or non-USASCII text omitted) and (ProQuest: Formulae and/or non-USASCII text omitted), which can accommodate all data. We discuss the viability of this possibility and emphasize the importance of separate measurements of the CP asymmetries in semileptonic B sub(d) and B sub(s) decays. All results have been obtained with the CKMfitter analysis package, featuring the frequentisi statistical approach and using Rfit to handle theoretical uncertainties.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM