The high-luminosity phase of the Large Hadron Collider (HL-LHC) will result in ten times higher particle background than measured during the first phase of LHC operation. In order to fully exploit ...the highly-demanding operating conditions during HL-LHC, the Compact Muon Solenoid (CMS) Collaboration will use Gas Electron Multiplier (GEM) detector technology. The technology will be integrated into the innermost region of the forward muon spectrometer of CMS as an additional muon station called GE1∕1. The primary purpose of this auxiliary station is to help in muon reconstruction and to control level-1 muon trigger rates in the pseudo-rapidity region 1.6≤|η|≤2.2. The new station will contain trapezoidal-shaped GEM detectors called GE1∕1 chambers. The design of these chambers is finalized, and the installation is in progress during the Long Shutdown phase two (LS-2) that started in 2019. Several full-size prototypes were built and operated successfully in various test beams at CERN. We describe performance measurements such as gain, efficiency, and time resolution of these prototype chambers, developed after years of R&D, and summarize their behavior in different gas compositions as a function of the applied voltage.
Full text
Available for:
IJS, IMTLJ, KILJ, KISLJ, NUK, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
The status of the GEM project for CMS high-η muon system Abbaneo, D.; Abbrescia, M.; Armagnaud, C. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2013, Volume:
732
Journal Article
Peer reviewed
Open access
The dedicated CMS R&D program was intended to study the feasibility of using micropattern detectors for the instrumentation of the vacant |η|>1.6 region in the present Resistive Plate Chambers (RPCs) ...endcap system. The proposed detector for CMS is a Triple-Gas Electron Multiplier (GEM) trapezoidal chamber, equipped with 1D readout. While during 2010–2011 the Collaboration worked on the prototyping of the detector, during the first part of 2012 a newly developed assembly technique to be used for the mass production was adopted. GEMs can provide precision tracking and fast trigger information, contributing on one hand to the improvement of the CMS muon Trigger and on the other hand to provide the missing redundancy in the high η region. In the view of the next LHC long shutdown (LS1) the CMS GEM Collaboration designed and built four full-size Triple GEM-based muon detectors.
Full text
Available for:
IJS, IMTLJ, KILJ, KISLJ, NUK, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
Abstract
The Gas Electron Multiplier (GEM) detectors of the GE1/1 station of the CMS experiment have been operated in the CMS magnetic field for the first time on the 7
th
of October 2021. During the ...magnetic field ramps, several discharge phenomena were observed, leading to instability in the GEM High Voltage (HV) power system. In order to reproduce the behavior, it was decided to conduct a dedicated test at the CERN North Area with the Goliath magnet, using four GE1/1 spare chambers. The test consisted in studying the characteristics of discharge events that occurred in different detector configurations and external conditions. Multiple magnetic field ramps were performed in sequence: patterns in the evolution of the discharge rates were observed with these data. The goal of this test is the understanding of the experimental conditions inducing discharges and short circuits in a GEM foil.
The results of this test lead to the development of procedure for the optimal operation and performance of GEM detectors in the CMS experiment during the magnet ramps. Another important result is the estimation of the probability of short circuit generation, at 68 % confidence level,
p
short
HV OFF
= 0.42
-0.35
+0.94
% with detector HV OFF and
p
short
HV OFF
< 0.49% with the HV ON. These numbers are specific for the detectors used during this test, but they provide a first quantitative indication on the phenomenon, and a point of comparison for future studies adopting the same procedure.
The CMS GEM collaboration is performing a feasibility study to install triple-GEM detectors in the forward region of the muon system (1.6 < |eta| < 2.4) of the CMS detector at the LHC. Such ...micro-pattern gas detectors are able to cope with the extreme particle rates that are expected in that region during the High Luminosity phase of the LHC. With their spatial resolution of order 100 micron GEMs would not only provide additional benefits in the CMS muon High Level Trigger, but also in the muon identification and track reconstruction, effectively combining tracking and triggering capabilities in one single device. The present status of the full project will be reviewed, highlighting all importants steps and achievements since the start of the R&D in 2009. Several small and full-size prototypes were constructed with different geometries and techniques. The baseline design of the triple-GEM detector for CMS will be described, along with the results from extensive test measurements of all prototypes both in the lab and in test beams at the CERN SPS. The proposed on- and off-detector electronics for the final system will be presented.
High rate behavior and discharge limits in micro-pattern detectors Bressan, A; Hoch, M; Pagano, P ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
03/1999, Volume:
424, Issue:
2
Journal Article
Peer reviewed
Open access
We present and discuss a set of systematic measurements, carried out with gaseous proportional micro-pattern detectors, in order to assess their maximum gain when irradiated with high-rate soft ...X-rays and heavily ionizing alpha particles. The inventory of detectors tested includes: micro-strips, micromegas, micro-dot, gas electron multiplier, CAT (compteur à trous), trench (or groove), micro-CAT (or WELL) detectors, as well as systems with two elements of gaseous amplification in cascade. We confirm the general trend of all single-stage detectors to follow Raether's criterion, i.e. a spontaneous transition from avalanche to streamer, followed by a discharge, when the avalanche size reaches a value of a few 10
7; a noticeable exception is the micro-dot counter holding more than 10
8. In multiple structures, where the gain is shared between two devices in cascade, the maximum overall gain under irradiation is increased by at least one order of magnitude; we speculate this to be a consequence of a voltage dependence of Raether's limit, larger for low operating potentials. Our conclusion is that only multiple devices can guarantee a sufficient margin of reliability for operation in harsh LHC running conditions.
Full text
Available for:
IJS, IMTLJ, KILJ, KISLJ, NUK, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
This contribution introduces a new type of Micropattern Gaseous Detector, the Fast Timing Micropattern (FTM) detector, utilizing fully Resistive WELL structures. The structure of the prototype will ...be described in detail and the results of the characterization study performed with an X-ray gun will be presented, together with the first results on time resolution based on data collected with muon/pion test beams.
Full text
Available for:
IJS, IMTLJ, KILJ, KISLJ, NUK, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
During the next shutdown of the LHC at CERN, the CMS experiment plans to start installing GEM detectors in the endcap (high pseudorapidity) region. These muon detectors have excellent spatial and ...temporal resolution as well as a high chemical stability and radiation hardness. A report is given on preliminary results of materials studies that aimed to fully characterize the GEM detector components before and after the exposure to a high-radiation environment.
Abstract
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high η ...region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstrator GEM detectors were installed in CMS during 2017 to gain operational experience and perform a preliminary investigation of detector performance. We present the results of triple-GEM detector performance studies performed in situ during normal CMS and LHC operations in 2018. The distribution of cluster size and the efficiency to reconstruct high
p
T
muons in proton-proton collisions are presented as well as the measurement of the environmental background
rate to produce hits in the GEM detector.
In order to cope with the harsh environment expected from the high luminosity LHC, the CMS forward muon system requires an upgrade. The two main challenges expected in this environment are an ...increase in the trigger rate and increased background radiation leading to a potential degradation of the particle ID performance. Additionally, upgrades to other subdetectors of CMS allow for extended coverage for particle tracking, and adding muon system coverage to this region will further enhance the performance of CMS.
Following an extensive R&D program, CMS has identified triple-foil gas electron multiplier (GEM) detectors as a solution for the first muon station in the region 1.6<|η|<2.2, while continuing R&D is ongoing for additional regions.