Akademska digitalna zbirka SLovenije - logo

Search results

Basic search    Expert search   

Currently you are NOT authorised to access e-resources SI consortium. For full access, REGISTER.

1 2 3 4 5
hits: 195
1.
  • Anomalous magnetic moment o... Anomalous magnetic moment of the muon
    Logashenko, I B; Eidelman, S I Physics Uspekhi, 05/2018, Volume: 61, Issue: 5
    Journal Article
    Peer reviewed

    The anomalous magnetic moment of the muon, aμ, is a unique quantity that allows high-precision tests of the Standard Model. Currently, a difference of 3 to 4 standard deviations is observed between ...
Full text
Available for: NUK, UL
2.
  • Measurement of the T20 comp... Measurement of the T20 component of tensor analyzing power for the incoherent π−-meson photoproduction on a deuteron
    Gauzshtein, V.V.; Darwish, E.M.; Fix, A.I. ... Nuclear physics. A, January 2024, 2024-01-00, Volume: 1041
    Journal Article
    Peer reviewed

    We present experimental results for T20 component of the tensor analyzing power for incoherent π− photoproduction on a deuteron. The experiment was performed on an internal tensor-polarized gas ...
Full text
Available for: GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, SAZU, SBCE, UL, UM, UPCLJ, UPUK, ZAGLJ
3.
  • Measurement of the e+e−→ ηπ... Measurement of the e+e−→ ηπ+π− cross section with the CMD-3 detector at the VEPP-2000 collider
    Gribanov, S. S.; Popov, A. S.; Akhmetshin, R. R. ... The journal of high energy physics, 01/2020, Volume: 2020, Issue: 1
    Journal Article
    Peer reviewed
    Open access

    A bstract The cross section of the process e + e − → ηπ + π − is measured using the data collected with the CMD-3 detector at the VEPP-2000 collider in the center-of-mass energy range from 1 . 1 to 2 ...
Full text
Available for: NUK, UL, UM, UPUK

PDF
4.
  • Measurement of the Pion For... Measurement of the Pion Form Factor with CMD-3 Detector and Its Implication to the Hadronic Contribution to Muon ( g − 2 )
    Ignatov, F. V.; Akhmetshin, R. R.; Amirkhanov, A. N. ... Physical review letters, 06/2024, Volume: 132, Issue: 23
    Journal Article
    Peer reviewed
    Open access

    The cross section of the process e + e − → π + π − has been measured in the center-of-mass energy range from 0.32 to 1.2 GeV with the CMD-3 detector at the electron-positron collider VEPP-2000. The ...
Full text
Available for: CMK, CTK, FMFMET, IJS, NUK, PNG, UM
5.
  • Measurement of the e + e − ... Measurement of the e + e − → π + π − cross section from threshold to 1.2 GeV with the CMD-3 detector
    Ignatov, F. V.; Akhmetshin, R. R.; Amirkhanov, A. N. ... Physical review. D, 6/2024, Volume: 109, Issue: 11
    Journal Article
    Peer reviewed

    The cross section of the process e + e − → π + π − has been measured in the center of mass energy range from 0.32 to 1.2 GeV with the CMD-3 detector at the electron-positron collider VEPP-2000. The ...
Full text
Available for: CMK, CTK, FMFMET, IJS, NUK, PNG, UM
6.
Full text

PDF
7.
  • Measurement of the negative... Measurement of the negative muon anomalous magnetic moment to 0.7 ppm
    Bennett, G W; Bousquet, B; Brown, H N ... Physical review letters, 04/2004, Volume: 92, Issue: 16
    Journal Article
    Peer reviewed

    The anomalous magnetic moment of the negative muon has been measured to a precision of 0.7 ppm (ppm) at the Brookhaven Alternating Gradient Synchrotron. This result is based on data collected in ...
Full text
Available for: CMK, CTK, FMFMET, IJS, NUK, PNG, UM

PDF
8.
  • Barrel calorimeter of the C... Barrel calorimeter of the CMD-3 detector
    Anisenkov, A.V.; Aulchenko, V.M.; Barkov, L.M. ... Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 12/2013, Volume: 732
    Journal Article
    Peer reviewed

    Since 2010 the CMD-3 detector has been collecting data at the e+e− collider VEPP-2000 at Budker Institute of Nuclear Physics. CMD-3 is a general purpose detector designed to study e+e− annihilation ...
Full text
Available for: GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
9.
  • Processing of the signals f... Processing of the signals from the Liquid Xenon Calorimeter for timing measurements
    Epshteyn, L.B.; Grebenuyk, A.A.; Kozyrev, A.N. ... Journal of instrumentation, 02/2017, Volume: 12, Issue: 2
    Journal Article
    Peer reviewed

    One of the goals of the Cryogenic Magnetic Detector at Budker Institute of Nuclear Physics SB RAS (Novosibirsk, Russia) is a study of hadron production in electron-positron collisions near threshold. ...
Full text
Available for: NUK, UL
10.
Full text
Available for: NUK, UL
1 2 3 4 5
hits: 195

Load filters