Summary
Background
Little is known about factors affecting the quality of life (QoL) of patients with vitiligo, and previous studies have shown conflicting results.
Objectives
To explore the QoL of ...patients with vitiligo and to identify factors affecting QoL.
Methods
A nationwide questionnaire‐based study was conducted with 1123 patients with vitiligo recruited from 21 hospitals in Korea from July 2015 to June 2016. Data were collected using a structured questionnaire for demographic information and the Skindex‐29 instrument. Mild or severely impaired QoL in patients with vitiligo was assessed according to each domain (symptoms, functioning and emotions) of Skindex‐29. Multivariate logistic regression analyses were performed to determine the factors associated with QoL.
Results
Of the enrolled participants, 609 were male and 514 female, with a mean age of 49·8 years (range 20–84). The median duration of disease was 3·0 years (range 0–60). Using multivariate logistic regression modelling, the involvement of visible body parts and a larger affected body surface area were consistently associated with QoL impairment in all three domains of Skindex‐29. Additionally, the QoL of patients aged 20–59 years, who potentially had a more active social life than older patients, was associated with functional impairment. Furthermore, a higher educational background was associated with emotional impairment.
Conclusions
A multitude of factors significantly influence the QoL of patients with vitiligo. A better appreciation of these factors would help the management of these patients.
What's already known about this topic?
Quality of life is highly impaired in patients with vitiligo.
What does this study add?
The involvement of visible body parts and a larger affected body surface area were consistently associated with impaired symptoms, functioning and emotions.
Vitiligo with nonvisible lesions also considerably compromises quality of life; vitiligo should not be regarded as a cosmetic problem.
Patients aged 20–59 years experienced significant functional impairment, and those with a higher educational background had more impairment in their emotions.
Linked Comment: Ezzedine and Eleftheriadou. Br J Dermatol 2018; 178:28–29.
Plain language summary available online
Respond to this article
Full text
Available for:
BFBNIB, FZAB, GIS, IJS, KILJ, NLZOH, NUK, OILJ, SAZU, SBCE, SBMB, UL, UM, UPUK
A long-standing paradigm in astrophysics is that collisions- or mergers-of two neutron stars form highly relativistic and collimated outflows (jets) that power Y-ray bursts of short (less than two ...seconds) duration. The observational support for this model, however, is only indirect. A hitherto outstanding prediction is that gravitational-wave events from such mergers should be associated with Y-ray bursts, and that a majority of these bursts should be seen off-axis, that is, they should point away from Earth. Here we report the discovery observations of the X-ray counterpart associated with the gravitational-wave event GW170817. Although the electromagnetic counterpart at optical and infrared frequencies is dominated by the radioactive glow (known as a 'kilonova') from freshly synthesized rapid neutron capture (r-process) material in the merger ejecta, observations at X-ray and, later, radio frequencies are consistent with a short Y-ray burst viewed off-axis. Our detection of X-ray emission at a location coincident with the kilonova transient provides the missing observational link between short Y-ray bursts and gravitational waves from neutron-star mergers, and gives independent confirmation of the collimated nature of the Y-ray-burst emission.
Full text
Available for:
IJS, KISLJ, NUK, SBMB, UL, UM, UPUK
The RENO experiment reports more precisely measured values of θ_{13} and |Δm_{ee}^{2}| using ∼2200 live days of data. The amplitude and frequency of reactor electron antineutrino (νover ¯_{e}) ...oscillation are measured by comparing the prompt signal spectra obtained from two identical near and far detectors. In the period between August 2011 and February 2018, the far (near) detector observed 103 212 (850 666) νover ¯_{e} candidate events with a background fraction of 4.8% (2.0%). A clear energy and baseline dependent disappearance of reactor νover ¯_{e} is observed in the deficit of the measured number of νover ¯_{e}. Based on the measured far-to-near ratio of prompt spectra, we obtain sin^{2}2θ_{13}=0.0896±0.0048(stat)±0.0047(syst) and |Δm_{ee}^{2}|=2.68±0.12(stat)±0.07(syst)×10^{-3} eV^{2}.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UL, UM
Primary cosmic-ray elemental spectra have been measured with the balloon-borne Cosmic Ray Energetics And Mass (CREAM) experiment since 2004. The third CREAM payload (CREAM-III) flew for 29 days ...during the 2007-2008 Antarctic season. Energies of incident particles above 1 TeV are measured with a calorimeter. Individual elements are clearly separated with a charge resolution of ∼0.12 e (in charge units) and ∼0.14 e for protons and helium nuclei, respectively, using two layers of silicon charge detectors. The measured proton and helium energy spectra at the top of the atmosphere are harder than other existing measurements at a few tens of GeV. The relative abundance of protons to helium nuclei is 9.53 0.03 for the range of 1 TeV/n to 63 TeV/n. This ratio is considerably smaller than other measurements at a few tens of GeV/n. The spectra become softer above ∼20 TeV. However, our statistical uncertainties are large at these energies and more data are needed.
An experiment to search for light sterile neutrinos is conducted at a reactor with a thermal power of 2.8 GW located at the Hanbit nuclear power complex. The search is done with a detector consisting ...of a ton of Gd-loaded liquid scintillator in a tendon gallery approximately 24 m from the reactor core. The measured antineutrino event rate is 1976 per day with a signal to background ratio of about 22. The shape of the antineutrino energy spectrum obtained from the eight-month data-taking period is compared with a hypothesis of oscillations due to active-sterile antineutrino mixing. No strong evidence of 3+1 neutrino oscillation is found. An excess around the 5 MeV prompt energy range is observed as seen in existing longer-baseline experiments. The mixing parameter sin^{2}2θ_{14} is limited up to less than 0.1 for Δm_{41}^{2} ranging from 0.2 to 2.3 eV^{2} with a 90% confidence level.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
Up to 40% of patients with non-small-cell lung cancer (NSCLC) and epidermal growth factor receptor (EGFR) mutations treated with EGFR tyrosine kinase inhibitors (TKIs) present with disease ...progression in the central nervous system (CNS), either as brain metastases (BM) or leptomeningeal metastases (LM). Osimertinib (80 mg), a third-generation, irreversible, oral EGFR TKI, has shown efficacy in active CNS metastases. However, efficacy of osimertinib 160 mg in BM or LM is unclear.
This prospective, single-arm, two cohort study evaluated the efficacy of osimertinib 160 mg in T790M-positive BM or LM NSCLC patients who progressed on prior EGFR TKI (NCT03257124) treatment. The primary end points were objective response rate (ORR) (H1 = 30%) for the BM cohort and overall survival (OS) (H1 = 5 months) for the LM cohort.
The median follow-up duration was 10.1 months and 9.6 months for the BM and LM cohorts, respectively. In the BM cohort, intracranial ORR and disease control rate were 55.0% and 77.5%, respectively. The median progression-free survival (PFS) was 7.6 months 95% confidence interval (CI) 5.0–16.6; the median OS was 16.9 months 95% CI 7.9–not reached (NR). In the LM cohort, intracranial disease control rate was 92.5% and complete response rate was 12.5%. The median OS was 13.3 months (95% CI 9.1–NR); the median PFS was 8.0 months (95% CI 7.2–NR). Subgroup analyses based on previous exposure to T790M-targeting agents, including osimertinib 80 mg or other third-generation EGFR TKIs, showed no difference in PFS in both the BM (n = 18, P = 0.39) and LM (n = 17, P = 0.85) cohorts. Previous radiotherapy favored PFS in the BM cohort (hazard ratio 0.42, P = 0.04). The most common adverse events were decreased appetite, diarrhea, and skin rash; however, most were grade 1–2.
Thus, osimertinib 160 mg demonstrated promising ORR and survival benefit with a tolerable safety profile in EGFR T790M-positive NSCLC patients with CNS metastasis who progressed on prior EGFR TKIs.
•Osimertinib 160 mg exhibited promising ORR and survival benefit in EGFR T790M-positive NSCLC patients with CNS metastasis.•As it caused only grade 1–2 adverse events, osimertinib 160 mg also showed a tolerable safety profile.•It is suitable for BM or LM patients after EGFR TKI treatment and those treated with EGFR T790M-targeting agents or radiotherapy.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Neutrino elastic scattering observation with NaI (NEON) is an experiment designed to detect neutrino-nucleus coherent scattering using reactor electron antineutrinos. NEON is based on an array of six ...NaI(Tl) crystals with a total mass of 13.3 kg, located at the tendon gallery that is 23.7 m away from a reactor core with a thermal power of 2.8 GW in the Hanbit nuclear power complex. The installation of the NEON detector was completed in December 2020, and since May 2021, the detector has acquired data at full reactor power. Based on the observed light yields of the NaI crystals of approximately 22, number of photoelectrons per unit keV electron-equivalent energy (keVee), and 6 counts/kg/keV/day background level at 2–6 keVee energy, coherent elastic neutrino-nucleus scattering (CE
ν
NS) observation sensitivity is evaluated as more than 3
σ
assuming 1-year reactor-on and 100 days reactor-off data, 0.2 keVee energy threshold, and 7 counts/keV/kg/day background in the signal region of 0.2
-
0.5 keVee. This paper describes the design of the NEON detector, including the shielding arrangement, configuration of NaI(Tl) crystals, and associated operating systems. The initial performance and associated sensitivity of the experiment are also presented.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
We present a background model for dark matter searches using an array of NaI(Tl) crystals in the COSINE-100 experiment that is located in the Yangyang underground laboratory. The model includes ...background contributions from both internal and external sources, including cosmogenic radionuclides and surface
210
Pb contamination. To build the model in the low energy region, with a threshold of 1 keV, we used a depth profile of
210
Pb contamination in the surface of the NaI(Tl) crystals determined in a comparison between measured and simulated spectra. We also considered the effect of the energy scale errors propagated from the statistical uncertainties and the nonlinear detector response at low energies. The 1.7 years COSINE-100 data taken between October 21, 2016 and July 18, 2018 were used for this analysis. Our Monte Carlo simulation provides a non-Gaussian peak around 50 keV originating from beta decays of bulk
210
Pb in a good agreement with the measured background. This model estimates that the activities of bulk
210
Pb and
3
H are dominating the background rate that amounts to an average level of
2.85
±
0.15
counts/day/keV/kg in the energy region of (1–6) keV, using COSINE-100 data with a total exposure of 97.7 kg
·
years.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK