Mutations in SCN2A, a gene encoding the voltage-gated sodium channel Nav1.2, have been associated with a spectrum of epilepsies and neurodevelopmental disorders. Here, we report the phenotypes of 71 ...patients and review 130 previously reported patients. We found that (i) encephalopathies with infantile/childhood onset epilepsies (≥3 months of age) occur almost as often as those with an early infantile onset (<3 months), and are thus more frequent than previously reported; (ii) distinct phenotypes can be seen within the late onset group, including myoclonic-atonic epilepsy (two patients), Lennox-Gastaut not emerging from West syndrome (two patients), and focal epilepsies with an electrical status epilepticus during slow sleep-like EEG pattern (six patients); and (iii) West syndrome constitutes a common phenotype with a major recurring mutation (p.Arg853Gln: two new and four previously reported children). Other known phenotypes include Ohtahara syndrome, epilepsy of infancy with migrating focal seizures, and intellectual disability or autism without epilepsy. To assess the response to antiepileptic therapy, we retrospectively reviewed the treatment regimen and the course of the epilepsy in 66 patients for which well-documented medical information was available. We find that the use of sodium channel blockers was often associated with clinically relevant seizure reduction or seizure freedom in children with early infantile epilepsies (<3 months), whereas other antiepileptic drugs were less effective. In contrast, sodium channel blockers were rarely effective in epilepsies with later onset (≥3 months) and sometimes induced seizure worsening. Regarding the genetic findings, truncating mutations were exclusively seen in patients with late onset epilepsies and lack of response to sodium channel blockers. Functional characterization of four selected missense mutations using whole cell patch-clamping in tsA201 cells-together with data from the literature-suggest that mutations associated with early infantile epilepsy result in increased sodium channel activity with gain-of-function, characterized by slowing of fast inactivation, acceleration of its recovery or increased persistent sodium current. Further, a good response to sodium channel blockers clinically was found to be associated with a relatively small gain-of-function. In contrast, mutations in patients with late-onset forms and an insufficient response to sodium channel blockers were associated with loss-of-function effects, including a depolarizing shift of voltage-dependent activation or a hyperpolarizing shift of channel availability (steady-state inactivation). Our clinical and experimental data suggest a correlation between age at disease onset, response to sodium channel blockers and the functional properties of mutations in children with SCN2A-related epilepsy.
Objective
Intravenous thrombolysis and endovascular therapy (IVT/EVT) are evidence‐based treatments for adults with arterial ischemic stroke (AIS). However, randomized controlled trials in pediatric ...patients are lacking. This study aimed to describe feasibility, safety, and outcome of IVT/EVT in children with AIS.
Methods
This retrospective study (01/2000–12/2015) included a multicenter, population‐based consecutive cohort of patients aged 1 month to 16 years, diagnosed with AIS and presenting with pediatric National Institutes of Health Stroke Scale (pedNIHSS) ≥ 4. Clinical and radiological data of patients receiving IVT/EVT were compared to those receiving standard care (SC) using linear regression to adjust for potential confounders. EVT included intra‐arterial thrombolysis and/or mechanical thrombectomy. Outcome was assessed 6 months after stroke using the pediatric stroke outcome measure (PSOM).
Results
Overall, 150 patients (age 7.1 ± 4.9 years, 55 37% females) presented with pedNIHSS ≥ 4. Recanalization treatment was performed in 16 (11%), of whom 5 (3%) were treated with IVT and 11 (7%) with EVT. Patients receiving recanalization treatment were older (mean age = 11.0 vs 6.9 years, p = 0.01) and more severely affected (median pedNIHSS = 13.5 vs 8.0, p < 0.001). Death and bleeding complications did not differ between the 2 groups. Median (interquartile range) PSOM 6 months after AIS was 2.5 (1–4.3) and 1 (0–2) in the IVT/EVT and SC groups, respectively (p = 0.014). However, after multiple linear regression analysis, only higher baseline pedNIHSS remained associated with an unfavorable outcome (p < 0.001).
Interpretation
Recanalization treatment is feasible and seems to be safe in severely affected pediatric AIS patients. The assessment of efficacy of IVT/EVT in pediatric stroke patients requires larger studies. Ann Neurol 2018;83:1125–1132
Full text
Available for:
BFBNIB, FZAB, GIS, IJS, KILJ, NLZOH, NUK, OILJ, SAZU, SBCE, SBMB, UL, UM, UPUK
Neonatal arterial ischemic stroke (NAIS) is associated with considerable lifetime burdens such as cerebral palsy, epilepsy, and cognitive impairment. Prospective epidemiologic studies that include ...outcome assessments are scarce. This study aimed to provide information on the epidemiology, clinical manifestations, infarct characteristics, associated clinical variables, treatment strategies, and outcomes of NAIS in a prospective, population-based cohort of Swiss children.
This prospective study evaluated the epidemiology, clinical manifestations, vascular territories, associated clinical variables, and treatment of all full-term neonates diagnosed with NAIS and born in Switzerland between 2000 and 2010. Follow-up was performed 2 years (mean 23.3 months, SD 4.3 months) after birth.
One hundred neonates (67 boys) had a diagnosis of NAIS. The NAIS incidence in Switzerland during this time was 13 (95% confidence interval CI, 11-17) per 100,000 live births. Seizures were the most common symptom (95%). Eighty-one percent had unilateral (80% left-sided) and 19% had bilateral lesions. Risk factors included maternal risk conditions (32%), birth complications (68%), and neonatal comorbidities (54%). Antithrombotic and antiplatelet therapy use was low (17%). No serious side effects were reported. Two years after birth, 39% were diagnosed with cerebral palsy and 31% had delayed mental performance.
NAIS in Switzerland shows a similar incidence as other population-based studies. About one-third of patients developed cerebral palsy or showed delayed mental performance 2 years after birth, and children with normal mental performance may still develop deficits later in life.
Purpose
The aim of this work is to shed light on the issue of reproducibility in MR image reconstruction in the context of a challenge. Participants had to recreate the results of “Advances in ...sensitivity encoding with arbitrary k‐space trajectories" by Pruessmann et al.
Methods
The task of the challenge was to reconstruct radially acquired multicoil k‐space data (brain/heart) following the method in the original paper, reproducing its key figures. Results were compared to consolidated reference implementations created after the challenge, accounting for the two most common programming languages used in the submissions (Matlab/Python).
Results
Visually, differences between submissions were small. Pixel‐wise differences originated from image orientation, assumed field‐of‐view, or resolution. The reference implementations were in good agreement, both visually and in terms of image similarity metrics.
Discussion and Conclusion
While the description level of the published algorithm enabled participants to reproduce CG‐SENSE in general, details of the implementation varied, for example, density compensation or Tikhonov regularization. Implicit assumptions about the data lead to further differences, emphasizing the importance of sufficient metadata accompanying open datasets. Defining reproducibility quantitatively turned out to be nontrivial for this image reconstruction challenge, in the absence of ground‐truth results. Typical similarity measures like NMSE of SSIM were misled by image intensity scaling and outlier pixels. Thus, to facilitate reproducibility, researchers are encouraged to publish code and data alongside the original paper. Future methodological papers on MR image reconstruction might benefit from the consolidated reference implementations of CG‐SENSE presented here, as a benchmark for methods comparison.
Full text
Available for:
BFBNIB, FZAB, GIS, IJS, KILJ, NLZOH, NUK, OILJ, SAZU, SBCE, SBMB, UL, UM, UPUK
The concept of complexity is used in palliative care (PC) to describe the nature of patients' situations and the extent of resulting needs and care demands. However, the term or concept is not ...clearly defined and operationalised with respect to its particular application in PC. As a complex problem, a care situation in PC is characterized by reciprocal, nonlinear relations and uncertainties. Dealing with complex problems necessitates problem-solving methods tailored to specific situations. The theory of complex adaptive systems (CAS) provides a framework for locating problems and solutions. This study aims to describe criteria contributing to complexity of PC situations from the professionals' view and to develop a conceptual framework to improve understanding of the concept of "complexity" and related elements of a PC situation by locating the complex problem "PC situation" in a CAS.
Qualitative interview study with 42 semi-structured expert (clinical/economical/political) interviews. Data was analysed using the framework method. The thematic framework was developed inductively. Categories were reviewed, subsumed and connected considering CAS theory.
The CAS of a PC situation consists of three subsystems: patient, social system, and team. Agents in the "system patient" are allocated to further subsystems on patient level: physical, psycho-spiritual, and socio-cultural. The "social system" and the "system team" are composed of social agents, who affect the CAS as carriers of characteristics, roles, and relationships. Environmental factors interact with the care situation from outside the system. Agents within subsystems and subsystems themselves interact on all hierarchical system levels and shape the system behaviour of a PC situation.
This paper provides a conceptual framework and comprehensive understanding of complexity in PC. The systemic view can help to understand and shape situations and dynamics of individual care situations; on higher hierarchical level, it can support an understanding and framework for the development of care structures and concepts. The framework provides a foundation for the development of a model to differentiate PC situations by complexity of patients and care needs. To enable an operationalisation and classification of complexity, relevant outcome measures mirroring the identified system elements should be identified and implemented in clinical practice.
Full text
Available for:
CEKLJ, DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Sex- and flow-related aortic valve calcification (AVC) studies are still limited in number, and data on the exact calcium quantity and distribution are scarce. Therefore, we aimed to (1) re-define ...the best threshold of AVC load to distinguish severe from moderate aortic stenosis (AS) in common AS entities and to (2) evaluate differences in the aortic annulus and left ventricular outflow tract (LVOT) calcium load. Nine hundred and thirty-eight patients with contrast-enhanced cardiac MSCT and moderate-to-severe aortic stenosis (AS) were retrospectively enrolled. Patients with severe AS ≤ 1.0 cm
2
(
n
= 841) were further separated into three AS entities: high gradient (HGAS,
n
= 370, 44.0%), paradoxical low gradient (pLGAS,
n
= 333, 39.6%), and classical low gradient (LGAS,
n
= 138, 16.4%). AVC, leaflet, and LVOT calcification were quantified. Aortic valve calcification scores were highest in severe HGAS, and lower in severe pLGAS and classical LGAS. In all severity and AS entities, the non-coronary cusp (NCC) was the most calcified one. LVOT calcification was consistently comparable between gender and AS entities. Accuracy of logistic regression was the highest in HGAS (male vs. female: AVC > 2156 Agatston units (AU), c-index 0.76; vs. AVC > 1292 AU, c-index 0.85; or AVC density > 406 AU/cm
2
, c-index 0.82; vs. > 259 AU/cm
2
, c-index 0.86; each
p
< 0.0001*) to diagnose severe AS. AVC could only be used in men to differentiate between severe LGAS and moderate AS. Data from this retrospective analysis indicate that the NCC is subject to pre-dominant degeneration throughout gender, AS severity, and several AS entities. AVC was consistently comparable in severe pLGAS and classical LGAS, but only AVC in severe LGAS could sufficiently distinguish from moderate AS in men. LVOT calcification failed to be a reliable indicator of accelerating AS.
Full text
Available for:
EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
Background Detailed visualization and precise measurements of aortic valve dimensions are critical for the success of transcatheter aortic valve implantation and for the prevention of complications. ...Currently, multislice computed tomography is the gold standard for assessment of the aortic annulus and surrounding structures to determine the prosthesis size. New technologies such as virtual reality (VR) not only enable 3‐dimensional (3D) visualization with the potential to improve understanding of anatomy and pathology but also allow measurements in 3D. This study aims to investigate the feasibility, accuracy, and reproducibility of VR for the visualization of the aortic valve, the surrounding structures, and its role in preprocedural sizing for transcatheter aortic valve implantation. Methods and Results Based on the preprocedural multislice computed tomography data, 3mensio measurements and 3D visualizations and measurements using VR software were performed retrospectively on 60 consecutive patients who underwent transcatheter aortic valve implantation at our heart center. There were no significant differences but strong correlations between the VR measurements compared with those performed with the 3mensio software. Furthermore, excellent or good intra‐ and interobserver reliability could be demonstrated for all values. In a structured questionnaire, users reported that VR simplified anatomical understanding, improved 3D comprehension of adjacent structures, and was associated with very good self‐perceived depth perception. Conclusions The use of VR for preprocedural transcatheter aortic valve implantation sizing is feasible and has precise and reproducible measurements. In addition, 3D visualization improves anatomical understanding and orientation. To evaluate the potential benefits of 3D visualization for planning further cardiovascular interventions, research in this field is needed.
Structural anti-reflective coating and bactericidal surfaces, as well as many other effects, rely on high-aspect-ratio (HAR) micro- and nanostructures, and thus, are of great interest for a wide ...range of applications. To date, there is no widespread fabrication of dense or isolated HAR nanopillars based on UV nanoimprint lithography (UV-NIL). In addition, little research on fabricating isolated HAR nanopillars via UV-NIL exists. In this work, we investigated the mastering and replication of HAR nanopillars with the smallest possible diameters for dense and isolated arrangements. For this purpose, a UV-based nanoimprint lithography process was developed. Stability investigations with capillary forces were performed and compared with simulations. Finally, strategies were developed in order to increase the stability of imprinted nanopillars or to convert them into nanoelectrodes. We present UV-NIL replication of pillars with aspect ratios reaching up to 15 with tip diameters down to 35 nm for the first time. We show that the stability could be increased by a factor of 58 when coating them with a 20 nm gold layer and by a factor of 164 when adding an additional 20 nm thick layer of SiN. The coating of the imprints significantly improved the stability of the nanopillars, thus making them interesting for a wide range of applications.