Sociocultural theory of body dissatisfaction posits that internalization of the media ideal and appearance comparison are predictors of body dissatisfaction, a key risk factor for eating disorders. ...However, no data exist regarding the longitudinal relationships between these variables. The aim of this study was to explore longitudinal relationships among internalization of the media-ideal, social appearance comparison, and body dissatisfaction. A sample of 277 Grade 7 school girls (M age = 12.77 years, SD = 0.44) completed measures of internalization of the media ideal, social appearance comparison, and body dissatisfaction at baseline, 8 months, and 14 months. Path analyses indicated that baseline internalization of the media ideal predicted social appearance comparison and body dissatisfaction at 8 months, and social appearance comparison at 8 months predicted body dissatisfaction at 14 months. A reciprocal effect emerged with body dissatisfaction at 8 months predicting internalization of the media ideal at 14 months. The findings inform sociocultural theory of body dissatisfaction, suggesting that internalization of the media ideal precedes and predicts appearance comparison and that body image interventions that target internalization of the media ideal, and social appearance comparison as well as body dissatisfaction are likely to be effective.
Full text
Available for:
CEKLJ, FFLJ, NUK, ODKLJ, PEFLJ, UPUK
Metabolites are building blocks of cellular function. These species are involved in enzyme-catalyzed chemical reactions and are essential for cellular function. Upstream biological disruptions result ...in a series of metabolomic changes and, as such, the metabolome holds a wealth of information that is thought to be most predictive of phenotype. Uncovering this knowledge is a work in progress. The field of metabolomics is still maturing; the community has leveraged proteomics experience when applicable and developed a range of sample preparation and instrument methodology along with myriad data processing and analysis approaches. Research focuses have now shifted toward a fundamental understanding of the biology responsible for metabolomic changes. There are several types of metabolomics experiments including both targeted and untargeted analyses. While untargeted, hypothesis generating workflows exhibit many valuable attributes, challenges inherent to the approach remain. This Critical Insight comments on these challenges, focusing on the identification process of LC-MS-based untargeted metabolomics studies—specifically in mammalian systems. Biological interpretation of metabolomics data hinges on the ability to accurately identify metabolites. The range of confidence associated with identifications that is often overlooked is reviewed, and opportunities for advancing the metabolomics field are described.
Graphical Abstract
ᅟ
Full text
Available for:
FZAB, GEOZS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UL, UM, UPUK, VKSCE, ZAGLJ
Body dissatisfaction is associated with impairment in women's quality of life (QoL). To date, research has not examined the relationship between body dissatisfaction and men's QoL, or sex differences ...in this relationship.
A community sample of 966 males and 1,031 females living in Australia provided information about their body dissatisfaction, mental health and physical health‐related QoL, and eating disorder symptoms. Data were analysed using three hierarchical multiple regressions and interactions between body dissatisfaction and sex were examined.
For both sexes, increasing levels of body dissatisfaction were associated with poorer mental and physical health‐related QoL and greater psychological distress. The adverse associations between body dissatisfaction and mental health‐related QoL, and between body dissatisfaction and psychological distress, were more pronounced for males.
High levels of body dissatisfaction may threaten the psychological and physical wellbeing of both men and women. Body dissatisfaction appears to be a public health problem, distinct from the eating disorders and other adverse psychological phenomena for which body dissatisfaction is commonly discussed as a risk factor. Males, historically understudied and underrepresented in body image research, warrant increased empirical attention.
Full text
Available for:
BFBNIB, FZAB, GEOZS, GIS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Here we examine the relationship among resolving power (R p), resolution (R pp), and collision cross section (CCS) for compounds analyzed in previous ion mobility (IM) experiments representing a wide ...variety of instrument platforms and IM techniques. Our previous work indicated these three variables effectively describe and predict separation efficiency for drift tube ion mobility spectrometry experiments. In this work, we seek to determine if our previous findings are a general reflection of IM behavior that can be applied to various instrument platforms and mobility techniques. Results suggest IM distributions are well characterized by a Gaussian model and separation efficiency can be predicted on the basis of the empirical difference in the gas-phase CCS and a CCS-based resolving power definition (CCS/ΔCCS). Notably traveling wave (TWIMS) was found to operate at resolutions substantially higher than a single-peak resolving power suggested. When a CCS-based R p definition was utilized, TWIMS was found to operate at a resolving power between 40 and 50, confirming the previous observations by Giles and co-workers. After the separation axis (and corresponding resolving power) is converted to cross section space, it is possible to effectively predict separation behavior for all mobility techniques evaluated (i.e., uniform field, trapped ion mobility, traveling wave, cyclic, and overtone instruments) using the equations described in this work. Finally, we are able to establish for the first time that the current state-of-the-art ion mobility separations benchmark at a CCS-based resolving power of >300 that is sufficient to differentiate analyte ions with CCS differences as small as 0.5%.
Full text
Available for:
IJS, KILJ, NUK, PNG, UL, UM
Social media has been associated with body dissatisfaction and eating disorder symptoms among young women and adolescent girls. However, despite notable evidence of susceptibility to body image ...pressures, it remains unknown whether these associations generalize to sexual minority men. A nationwide sample of 2,733 sexual minority men completed an online survey advertised to Australian and New Zealand users of a popular dating app. Participants answered questions about how frequently they used 11 different social media platforms in addition to questions about their dating app use, body image, eating disorder symptoms, and anabolic steroids. Facebook, Youtube, Instagram, and Snapchat were the most frequently used social media platforms. A pattern of small-sized and positive associations emerged between social media use and body dissatisfaction, eating disorder symptoms, and thoughts about using anabolic steroids. Facebook, Instagram, and Snapchat evidenced the strongest associations. The associations of social media use with both muscularity dissatisfaction and eating disorder symptoms were stronger for image-centric social media platforms (e.g., Instagram) than nonimage-centric platforms (e.g., Wordpress); no differences were observed for body fat dissatisfaction, height dissatisfaction, or thoughts about using anabolic steroids. Previously documented associations of social media use with body dissatisfaction and related variables among women and girls appear to generalize to sexual minority men. Social media platforms that more centrally involve imagery may be of greater concern than nonimage-centric platforms. Additional research with sexual minority men is needed to elucidate the distinctions between adaptive and maladaptive social media use in the context of body dissatisfaction, eating disorders, and anabolic steroid use.
Lipids are highly structurally diverse molecules involved in a wide variety of biological processes. Here, we use high precision ion mobility-mass spectrometry to compile a structural database of 456 ...mass-resolved collision cross sections (CCS) of sphingolipid and glycerophospholipid species. Our CCS database comprises sphingomyelin, cerebroside, ceramide, phosphatidylethanolamine, phosphatidylcholine, phosphatidylserine, and phosphatidic acid classes. Primary differences observed are between lipid categories, with sphingolipids exhibiting 2-6% larger CCSs than glycerophospholipids of similar mass, likely a result of the sphingosine backbone's restriction of the sn1 tail length, limiting gas-phase packing efficiency. Acyl tail length and degree of unsaturation are found to be the primary structural descriptors determining CCS magnitude, with degree of unsaturation being four times as influential per mass unit. The empirical CCS values and previously unmapped quantitative structural trends detailed in this work are expected to facilitate prediction of CCS in broadscale lipidomics research.
Introduction
This narrative review focusing on critical care echocardiography (CCE) has been written by a group of experts in the field, with the aim of outlining the state of the art in CCE in the ...10 years after its official recognition and definition.
Results
In the last 10 years, CCE has become an essential branch of critical care ultrasonography and has gained general acceptance. Its use, both as a diagnostic tool and for hemodynamic monitoring, has increased markedly, influencing contemporary cardiorespiratory management. Recent studies suggest that the use of CCE may have a positive impact on outcomes. CCE may be used in critically ill patients in many different clinical situations, both in their early evaluation of in the emergency department and during intensive care unit (ICU) admission and stay. CCE has also proven its utility in perioperative settings, as well as in the management of mechanical circulatory support. CCE may be performed with very simple diagnostic objectives. This application, referred to as basic CCE, does not require a high level of training. Advanced CCE, on the other hand, uses ultrasonography for full evaluation of cardiac function and hemodynamics, and requires extensive training, with formal certification now available. Indeed, recent years have seen the creation of worldwide certification in advanced CCE. While transthoracic CCE remains the most commonly used method, the transesophageal route has gained importance, particularly for intubated and ventilated patients.
Conclusion
CCE is now widely accepted by the critical care community as a valuable tool in the ICU and emergency department, and in perioperative settings.
Full text
Available for:
EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NLZOH, NUK, OBVAL, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
Collision cross section (CCS) measurement of lipids using traveling wave ion mobility-mass spectrometry (TWIM-MS) is of high interest to the lipidomics field. However, currently available calibrants ...for CCS measurement using TWIM are predominantly peptides that display quite different physical properties and gas-phase conformations from lipids, which could lead to large CCS calibration errors for lipids. Here we report the direct CCS measurement of a series of phosphatidylcholines (PCs) and phosphatidylethanolamines (PEs) in nitrogen using a drift tube ion mobility (DTIM) instrument and an evaluation of the accuracy and reproducibility of PCs and PEs as CCS calibrants for phospholipids against different classes of calibrants, including polyalanine (PolyAla), tetraalkylammonium salts (TAA), and hexakis(fluoroalkoxy)phosphazines (HFAP), in both positive and negative modes in TWIM-MS analysis. We demonstrate that structurally mismatched calibrants lead to larger errors in calibrated CCS values while the structurally matched calibrants, PCs and PEs, gave highly accurate and reproducible CCS values at different traveling wave parameters. Using the lipid calibrants, the majority of the CCS values of several classes of phospholipids measured by TWIM are within 2% error of the CCS values measured by DTIM. The development of phospholipid CCS calibrants will enable high-accuracy structural studies of lipids and add an additional level of validation in the assignment of identifications in untargeted lipidomics experiments.
Full text
Available for:
IJS, KILJ, NUK, PNG, UL, UM