To investigate the reproducibility for the iridocorneal angle evaluations using the pictures obtained by a gonioscopic camera, Gonioscope GS-1 (Nidek Co., Gamagori, Japan).
The pragmatic ...within-patient comparative diagnostic evaluations for 140 GS-1 gonio-images obtained from 35 eyes of 35 patients at four ocular sectors (superior, temporal, inferior, and nasal angles) were conducted by five independent ophthalmologists including three glaucoma specialists in a masked fashion twice, 1 week apart. We undertook the observer agreement and correlation analyses of Scheie's angle width and pigmentation gradings and detection of peripheral anterior synechia and Sampaolesi line.
The respective Fleiss' kappa values for the four elements between manual gonioscopy and automated gonioscope by the glaucoma specialist were 0.22, 0.40, 0.32 and 0.58. Additionally, the respective intraobserver agreements for the four elements by the glaucoma specialist each were 0.32 to 0.65, 0.24 to 0.71, 0.35 to 0.70, and 0.20 to 0.76; the Fleiss' kappa coefficients for the four elements among the three glaucoma specialists were, respectively, 0.31, 0.38, 0.31, and 0.17; the Fleiss' kappa coefficients for the angle width and pigmentation gradings between the two glaucoma specialists each were 0.30 to 0.35, and 0.29 to 0.43, respectively. Overall, the Kendall's tau coefficients for the angle gradings reflected the positive correlations in the evaluations.
Our findings suggested slight-to-substantial intraobserver agreement and slight-to-fair (among the three) or fair-to-moderate (between the two each) interobserver agreement for the angle assessments using GS-1 gonio-photos even by glaucoma specialists. Sufficient training and a solid consensus should allow us to perform more reliable angle assessments using gonio-photos with high reproducibility.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
To develop a large-scale real clinical database of glaucoma (Japanese Archive of Multicentral Databases in Glaucoma: JAMDIG) and to investigate the effect of treatment.
The study included a total of ...1348 eyes of 805 primary open-angle glaucoma patients with 10 visual fields (VFs) measured with 24-2 or 30-2 Humphrey Field Analyzer (HFA) and intraocular pressure (IOP) records in 10 institutes in Japan. Those with 10 reliable VFs were further identified (638 eyes of 417 patients). Mean total deviation (mTD) of the 52 test points in the 24-2 HFA VF was calculated, and the relationship between mTD progression rate and seven variables (age, mTD of baseline VF, average IOP, standard deviation (SD) of IOP, previous argon/selective laser trabeculoplasties (ALT/SLT), previous trabeculectomy, and previous trabeculotomy) was analyzed.
The mTD in the initial VF was -6.9 ± 6.2 dB and the mTD progression rate was -0.26 ± 0.46 dB/year. Mean IOP during the follow-up period was 13.5 ± 2.2 mm Hg. Age and SD of IOP were related to mTD progression rate. However, in eyes with average IOP below 15 and also 13 mm Hg, only age and baseline VF mTD were related to mTD progression rate.
Age and the degree of VF damage were related to future progression. Average IOP was not related to the progression rate; however, fluctuation of IOP was associated with faster progression, although this was not the case when average IOP was below 15 mm Hg.
We are pleased to bring you the 5th edition of the Glaucoma Clinical Practice Guidelines. Clinical practice guidelines are based on evidence (scientific grounds). It is a document that presents the ...treatment that is the most appropriate for the patient. "Glaucoma Clinical Guidelines" was first published in 2003. This was the first guideline for glaucoma treatment in Japan. The principle of glaucoma treatment is to lower intraocular pressure. Means for lowering intraocular pressure includes drugs, lasers, and surgery; Glaucoma is a disease that should be considered as a complex syndrome rather than a single condition. Therefore, the actual medical treatment is not as simple as one word. This time we set the Clinical Questionnaire with a focus on glaucoma treatment. We hope that you will take advantage of the 5th edition.
Full text
Available for:
EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
Purpose
A brimonidine tartrate 0.1%/brinzolamide 1% fixed-dose combination (BBFC) was recently approved for glaucoma and ocular hypertension treatment in Japan. We investigated the efficacy and ...safety of BBFC used concomitantly with prostaglandin analogs (PG) or a PG/beta-blocker fixed-dose combination (PG/beta FC).
Study design
This was a prospective, open-label, multicenter study.
Patients and methods
We enrolled Japanese patients with open-angle glaucoma. BBFC (Ailamide) was concomitantly administered to either the PG or the PG/beta FC group, and intraocular pressure (IOP) and safety were evaluated at 4 and 12 weeks. The groups were stratified into low and high IOP baseline groups based on the median baseline IOP.
Results
We enrolled 100 patients, 91 of whom completed the 12-week follow-up. The mean ages were 67.1 and 65.7 years in the PG group (n = 45, baseline IOP of 15.7 ± 2.3 mmHg) and the PG/beta FC group (n = 46, baseline IOP of 16.3 ± 2.3 mmHg), respectively. After BBFC administration, IOPs at 4 and 12 weeks were 13.0 ± 2.0 and 13.0 ± 2.6 mmHg (
P
< 0.0001) in the PG group, respectively, and 13.7 ± 2.4 and 13.7 ± 2.2 mmHg (
P
< 0.0001) in the PG/beta FC group, respectively. IOP decreased by – 2.0 ± 1.8 mmHg (
P
< 0.0001) and –1.9 ± 1.4 mmHg (
P
< 0.0001) in the low baseline PG group (14.1 mmHg) and low baseline PG/beta FC group (14.8 mmHg) at 12 weeks, respectively. Sixteen adverse events were identified, all of which were common and did not affect visual acuity.
Conclusions
BBFC can be used concomitantly with PG or PG/beta FC to reduce IOP without serious complications.
Full text
Available for:
EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
The aim of the study was to investigate the usefulness of processing visual field (VF) using a variational autoencoder (VAE). The training data consisted of 82,433 VFs from 16,836 eyes. Testing ...dataset 1 consisted of test-retest VFs from 104 eyes with open angle glaucoma. Testing dataset 2 was series of 10 VFs from 638 eyes with open angle glaucoma. A VAE model to reconstruct VF was developed using the training dataset. VFs in the testing dataset 1 were then reconstructed using the trained VAE and the mean total deviation (mTD) was calculated (mTD
). In testing dataset 2, the mTD value of the tenth VF was predicted using shorter series of VFs. A similar calculation was carried out using a weighted linear regression where the weights were equal to the absolute difference between mTD and mTD
. In testing dataset 1, there was a significant relationship between the difference between mTD and mTD
from the first VF and the difference between mTD in the first and second VFs. In testing dataset 2, mean squared prediction errors with the weighted mTD trend analysis were significantly smaller than those form the unweighted mTD trend analysis.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
The Glaucoma Stereo Analysis Study (GSAS) is a multicenter collaborative study of the characteristics of glaucomatous optic disc morphology using a stereo fundus camera. This study evaluated the ...retinal vessel calibers and correlations using GSAS fundus photographs between retinal vessels and 38 optic nerve head (ONH) morphologic parameters comprehensively. In all 240 eyes, the mean central retinal arteriolar equivalent (CRAE) and central retinal venular equivalent (CRVE) were 138.4 and 216.5 μm, respectively; the CRAE correlated with age, visual field scores and 19 ONH parameters and CRVE correlated with age, intraocular pressure, visual field scores and 11 ONH parameters. Among the different optic disc appearances including focal ischemia (FI) (n = 53, 22%), generalized enlargement (GE) (n = 53, 22%), myopic glaucoma (MY) (n = 112, 47%), and senile sclerosis (SS) (n = 22, 9%), the CRAE did not differ significantly; CRVE was significantly narrower in SS than in FI and MY. In FI, GE, MY, and SS disc types, CRAE correlated with 3, 14, 9, and 2 ONH parameters, respectively, and CRVE corelated with 9, 0, 12, and 6 ONH parameters, respectively. We confirmed previous observations on the effect of retinal vessel narrowing on glaucomatous changes in the ONH and visual field. The associations between retinal vessel caliber and ONH morphologic parameters vary among different optic disc appearances, suggesting different effects of vascular changes in each disc type.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
To validate the prediction accuracy of variational Bayes linear regression (VBLR) with two datasets external to the training dataset.
The training dataset consisted of 7268 eyes of 4278 subjects from ...the University of Tokyo Hospital. The Japanese Archive of Multicentral Databases in Glaucoma (JAMDIG) dataset consisted of 271 eyes of 177 patients, and the Diagnostic Innovations in Glaucoma Study (DIGS) dataset includes 248 eyes of 173 patients, which were used for validation. Prediction accuracy was compared between the VBLR and ordinary least squared linear regression (OLSLR). First, OLSLR and VBLR were carried out using total deviation (TD) values at each of the 52 test points from the second to fourth visual fields (VFs) (VF2-4) to 2nd to 10th VF (VF2-10) of each patient in JAMDIG and DIGS datasets, and the TD values of the 11th VF test were predicted every time. The predictive accuracy of each method was compared through the root mean squared error (RMSE) statistic.
OLSLR RMSEs with the JAMDIG and DIGS datasets were between 31 and 4.3 dB, and between 19.5 and 3.9 dB. On the other hand, VBLR RMSEs with JAMDIG and DIGS datasets were between 5.0 and 3.7, and between 4.6 and 3.6 dB. There was statistically significant difference between VBLR and OLSLR for both datasets at every series (VF2-4 to VF2-10) (P < 0.01 for all tests). However, there was no statistically significant difference in VBLR RMSEs between JAMDIG and DIGS datasets at any series of VFs (VF2-2 to VF2-10) (P > 0.05).
VBLR outperformed OLSLR to predict future VF progression, and the VBLR has a potential to be a helpful tool at clinical settings.
To investigate the success rate of eye drop instillation in glaucoma patients with visual field defect as well as non-glaucoma volunteers. Factors that may affect the success rate of eye drop ...instillation were also evaluated.
A prospective, observational study.
Seventy-eight glaucoma patients and 85 non-glaucoma volunteers were recruited in this study.
Open angle glaucoma patients with visual field defect as well as non-glaucoma volunteers were asked to video record their procedures of eye drop instillation using a 5-mL plastic bottle of artificial tear solution. Success of eye drop instillation was judged on video based on the first one drop of solution successfully applied on the cornea, by two investigators.
Success rate of eye drop instillation in glaucoma patients and non-glaucoma volunteers. Factors related to success rate of eye drop instillation, such as visual field defect and clinical characteristics, were also analyzed using multivariable logistic regression.
No significant deference in mean age was observed between two groups (glaucoma: 64.5 ± 14.4 years, non-glaucoma: 60.9 ± 14.1 years, P = 0.1156). Success rate of eye drop instillation was significantly lower (P = 0.0215) in glaucoma patients (30/78; 38.5%) than in non-glaucoma volunteers (48/85; 56.5%). The most frequent reason of instillation failure in glaucoma patients was touching the bulbar conjunctiva, cornea, eyelid or eyelashes with the tip of the bottle (29.5%). Multivariable logistic regression analysis identified lower corrected visual acuity (VA) (≤ 1.0; odds ratio OR = 0.20, 95% confidence interval CI 0.04-0.93, P = 0.0411), lower mean deviation (MD) (< -12 dB; OR = 0.20, 95% CI 0.05-0.86, P = 0.0307) and visual field defect (VFD) in the inferior hemifield (OR = 0.11, 95% CI 0.02-0.34, P < 0.001) to be significantly related to instillation failure in glaucoma patients.
Success rate of eye drop instillation was significantly lower in glaucoma patients than in non-glaucoma volunteers. Corrected VA ≤ 1.0, MD < -12 dB and/or VFD in the inferior hemifield may be related to failure of eye drop instillation.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
To compare the success rates of eye drop instillation in the sitting position and supine position among Japanese patients with ocular diseases (cataract, glaucoma, or retinal and vitreous diseases).
...Patients who were hospitalized in Okayama University Hospital for eye surgery were studied. Instillation procedures of each patient in both the sitting and supine positions were recorded using a video camera at the time of instillation. We defined "success" when one drop fell accurately onto the ocular surface at the first attempt. Instillation of two or more drops, drops delivered to a site other than the eye surface, and touching the eyelashes, eyelids, or conjunctiva with the tip of the eye drop bottle were regarded as "failure". We excluded patients with vision below counting finger.
One-hundred and two patients (54 males and 58 females, aged 70.2 ± 12.3 years) with ocular disease who were hospitalized for surgery (cataract: 61.8%, glaucoma: 15.7%, retinal and vitreous diseases: 22.5%) were included in this prospective observational study. The mean duration of eye drop use was 3.1 ± 5.2 years. The success rate of eye drop instillation was significantly higher in the supine position than in the sitting position (64.7% vs. 50%, P = 0.0039). The mean age was significantly higher in the failure group than in the success group (74.0 ± 11.5 vs. 67.7 ± 12.4 years, P = 0.0085) for the sitting position, but not significantly different for the supine position (72.3 ± 12.9 vs. 70.1 ± 12.0 years, P = 0.3849). No significant differences in mean duration of drop use, mean corrected VA, and mean spherical equivalent refraction were observed between success and failure groups, for both sitting and supine positions.
In the present study, the success rate of eye drop instillation was significantly higher when applied in the supine position than in the sitting position.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK