Abstract Objectives This study evaluated the safety and effectiveness of self-expanding transcatheter aortic valve replacement (TAVR) in patients with surgical valve failure (SVF). Background ...Self-expanding TAVR is superior to medical therapy for patients with severe native aortic valve stenosis at increased surgical risk. Methods The CoreValve U.S. Expanded Use Study was a prospective, nonrandomized study that enrolled 233 patients with symptomatic SVF who were deemed unsuitable for reoperation. Patients were treated with self-expanding TAVR and evaluated for 30-day and 1-year outcomes after the procedure. An independent core laboratory was used to evaluate serial echocardiograms for valve hemodynamics and aortic regurgitation. Results SVF occurred through stenosis (56.4%), regurgitation (22.0%), or a combination (21.6%). A total of 227 patients underwent attempted TAVR and successful TAVR was achieved in 225 (99.1%) patients. Patients were elderly (76.7 ± 10.8 years), had a Society of Thoracic Surgeons Predicted Risk of Mortality score of 9.0 ± 6.7%, and were severely symptomatic (86.8% New York Heart Association functional class III or IV). The all-cause mortality rate was 2.2% at 30 days and 14.6% at 1 year; major stroke rate was 0.4% at 30 days and 1.8% at 1 year. Moderate aortic regurgitation occurred in 3.5% of patients at 30 days and 7.4% of patients at 1 year, with no severe aortic regurgitation. The rate of new permanent pacemaker implantation was 8.1% at 30 days and 11.0% at 1 year. The mean valve gradient was 17.0 ± 8.8 mm Hg at 30 days and 16.6 ± 8.9 mm Hg at 1 year. Factors significantly associated with higher discharge mean aortic gradients were surgical valve size, stenosis as modality of SVF, and presence of surgical valve prosthesis patient mismatch (all p < 0.001). Conclusions Self-expanding TAVR in patients with SVF at increased risk for surgery was associated with a low 1-year mortality and major stroke rate, significantly improved aortic valve hemodynamics, and low rates of moderate and no severe residual aortic regurgitation, with improved quality of life.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Coronary computed tomography angiography (CTA) assessment of calcified or complex coronary lesions is frequently challenging. Transluminal attenuation gradient (TAG), defined as the linear regression ...coefficient between luminal attenuation and axial distance, has a potential to evaluate the degree of coronary stenosis. We examined the value of TAG in determining the stenosis severity on 64-slice coronary CTA. The value of TAG of 370 major coronary arteries was measured from 7,263 intervals of 5-mm length. Compared with coronary CTA and invasive coronary angiography, TAG decreased consistently and significantly with maximum stenosis severity on a per-vessel basis, from −1.91 ± 4.25 Hounsfield units/10 mm for diameter stenosis of 0% to 49% to −13.37 ± 9.81 Hounsfield units/10 mm for diameter stenosis of 100% (p < 0.0001). Adding TAG to the interpretation of coronary CTA improved diagnostic accuracy (p = 0.001), especially in vessels with calcified lesions (N = 127; net reclassification improvement 0.095; p = 0.046). TAG appears to be able to contribute to improved classification of coronary artery stenosis severity in coronary CTA, especially in severely calcified lesions.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Abstract Background In patients with severe aortic stenosis at increased risk for surgery, self-expanding transcatheter aortic valve replacement (TAVR) is associated with improved 2-year survival ...compared with surgery. Objectives This study sought to determine whether this clinical benefit was sustained over time. Methods Patients with severe aortic stenosis deemed at increased risk for surgery by a multidisciplinary heart team were randomized 1:1 to TAVR or open surgical valve replacement (SAVR). Three-year clinical and echocardiographic outcomes were obtained in those patients with an attempted procedure. Results A total of 797 patients underwent randomization at 45 U.S. centers; 750 patients underwent an attempted procedure. Three-year all-cause mortality or stroke was significantly lower in TAVR patients (37.3% vs. 46.7% in SAVR; p = 0.006). Adverse clinical outcome components were also reduced in TAVR patients compared with SAVR patients, including all-cause mortality (32.9% vs. 39.1%, respectively; p = 0.068), all stroke (12.6% vs. 19.0%, respectively; p = 0.034), and major adverse cardiovascular or cerebrovascular events (40.2% vs. 47.9%, respectively; p = 0.025). At 3 years aortic valve hemodynamics were better with TAVR patients (mean aortic valve gradient 7.62 ± 3.57 mm Hg vs. 11.40 ± 6.81 mm Hg in SAVR; p < 0.001), although moderate or severe residual aortic regurgitation was higher in TAVR patients (6.8% vs. 0.0% in SAVR; p < 0.001). There was no clinical evidence of valve thrombosis in either group. Conclusions Patients with severe aortic stenosis at increased risk for surgery had improved 3-year clinical outcomes after TAVR compared with surgery. Aortic valve hemodynamics were more favorable in TAVR patients without differences in structural valve deterioration. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902 )
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Abstract Background The U.S. pivotal trial for the self-expanding valve found that among patients with severe aortic stenosis at increased risk for surgery, the 1-year survival rate was 4.9 ...percentage points higher in patients treated with a self-expanding transcatheter aortic valve bioprosthesis than in those treated with a surgical bioprosthesis. Objectives Longer-term clinical outcomes were examined to confirm if this mortality benefit is sustained. Methods Patients with severe aortic stenosis who were at increased surgical risk were recruited. Eligible patients were randomly assigned in a 1:1 ratio to transcatheter aortic valve replacement with the self-expanding transcatheter valve (transcatheter aortic valve replacement TAVR group) or to aortic valve replacement with a surgical bioprosthesis (surgical group). The 2-year clinical and echocardiographic outcomes were evaluated in these patients. Results A total of 797 patients underwent randomization at 45 centers in the United States. The rate of 2-year all-cause mortality was significantly lower in the TAVR group (22.2%) than in the surgical group (28.6%; log-rank test p < 0.05) in the as-treated cohort, with an absolute reduction in risk of 6.5 percentage points. Similar results were found in the intention-to-treat cohort (log-rank test p < 0.05). The rate of 2-year death or major stroke was significantly lower in the TAVR group (24.2%) than in the surgical group (32.5%; log-rank test p = 0.01). Conclusions In patients with severe aortic stenosis who are at increased surgical risk, the higher rate of survival with a self-expanding TAVR compared with surgery was sustained at 2 years. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902 )
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
The aims of this study were to evaluate the feasibility of real-time 3-dimensional (3D) transesophageal echocardiography in the intraoperative assessment of mitral valve (MV) pathology and to compare ...this novel technique with 2-dimensional (2D) transesophageal echocardiography.
Forty-two consecutive patients undergoing MV repair for mitral regurgitation (MR) were studied prospectively. Intraoperative 2D and 3D transesophageal echocardiographic (TEE) examinations were performed using a recently introduced TEE probe that provides real-time 3D imaging. Expert echocardiographers blinded to 2D TEE findings assessed the etiology of MR on 3D transesophageal echocardiography. Similarly, experts blinded to 3D TEE findings assessed 2D TEE findings. Both were compared with the anatomic findings reported by the surgeon.
At the time of surgical inspection, ischemic MR was identified in 12% of patients, complex bileaflet myxomatous disease in 31%, and specific scallop disease in 55%. Three-dimensional TEE image acquisition was performed in a short period of time (60 +/- 18 seconds) and was feasible in all patients, with optimal (36%) or good (33%) imaging quality in the majority of cases. Three-dimensional TEE imaging was superior to 2D TEE imaging in the diagnosis of P1, A2, A3, and bileaflet disease (P < .05).
Real-time 3D transesophageal echocardiography is a feasible method for identifying specific MV pathology in the setting of complex disease and can be expeditiously used in the intraoperative evaluation of patients undergoing MV repair.
Objectives This study sought to evaluate the safety and efficacy of the CoreValve transcatheter heart valve (THV) for the treatment of severe aortic stenosis in patients at extreme risk for surgery. ...Background Untreated severe aortic stenosis is a progressive disease with a poor prognosis. Transcatheter aortic valve replacement (TAVR) with a self-expanding bioprosthesis is a potentially effective therapy. Methods We performed a prospective, multicenter, nonrandomized investigation evaluating the safety and efficacy of self-expanding TAVR in patients with symptomatic severe aortic stenosis with prohibitive risks for surgery. The primary endpoint was a composite of all-cause mortality or major stroke at 12 months, which was compared with a pre-specified objective performance goal (OPG). Results A total of 41 sites in the United States recruited 506 patients, of whom 489 underwent attempted treatment with the CoreValve THV. The rate of all-cause mortality or major stroke at 12 months was 26.0% (upper 2-sided 95% confidence bound: 29.9%) versus 43.0% with the OPG (p < 0.0001). Individual 30-day and 12-month events included all-cause mortality (8.4% and 24.3%, respectively) and major stroke (2.3% and 4.3%, respectively). Procedural events at 30 days included life-threatening/disabling bleeding (12.7%), major vascular complications (8.2%), and need for permanent pacemaker placement (21.6%). The frequency of moderate or severe paravalvular aortic regurgitation was lower 12 months after self-expanding TAVR (4.2%) than at discharge (10.7%; p = 0.004 for paired analysis). Conclusions TAVR with a self-expanding bioprosthesis was safe and effective in patients with symptomatic severe aortic stenosis at prohibitive risk for surgical valve replacement. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902 )
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Objectives The purpose of the study was to identify echocardiographic predictors of adverse outcome in patients implanted with continuous-flow left ventricular assist devices (LVAD). Background ...Continuous flow LVAD have become part of the standard of care for the treatment of advanced heart failure. However, knowledge of echocardiographic predictors of outcome after LVAD are lacking. Methods Overall, 83 patients received continuous-flow LVAD (HeartMate II, Thoratec Corporation, Pleasanton, California) from February 2007 to June 2010. The LVAD database, containing various echocardiographic parameters, was examined to analyze their influence on in-hospital mortality, a compound cardiac event (in-hospital mortality or acute right ventricular RV dysfunction), and long-term mortality. Results Eight patients died before discharge (operative mortality 9.6%), and another 15 patients were considered to have acute RV dysfunction immediately after surgery. Patients with relatively small left ventricular end-diastolic diameters (<63 mm) had significantly higher risk for in-hospital mortality (odds ratio OR: 0.9; 95% confidence interval CI: 0.83 to 0.99; p = 0.04) or occurrence of the compound cardiac event (OR: 0.89; 95% CI: 0.84 to 0.95; p < 0.001). The most significant predictor of outcome was the decreased timing interval between the onset and the cessation of tricuspid regurgitation flow corrected for heart rate (TRDc), a surrogate for early systolic equalization of RV and right atrial pressure. Short TRDc predicted in-hospital mortality (OR: 0.85; 95% CI: 0.74 to 0.97; p = 0.01) and the compound cardiac event (OR: 0.83; 95% CI: 0.74 to 0.91; p < 0.0001). Multivariate analysis based on a logistic regression model demonstrated that the accuracy of predicting the 30-day compound adverse outcome was improved with the addition of echocardiographic variables when added to the commonly used hemodynamic or clinical scores. TRDc predicted long-term survival, with adjusted risk ratios of 0.89 for death from any cause (95% CI: 0.83 to 0.96; p = 0.003) and 0.88 for cardiac-related death (95% CI: 0.77 to 0.98; p = 0.03). Conclusions The presence of either a relatively small left ventricle (<63 mm) or early systolic equalization of RV and right atrial pressure (short TRDc) demonstrated by echocardiography is associated with increased 30-day morbidity and mortality. Prediction of early adverse outcomes by echocardiographic parameters is additive to laboratory or hemodynamic variables.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Abstract Background The classification of aortic dissection into acute (<14 days from symptom onset) versus chronic (≥14 days) is based on survival estimates of patients treated decades before modern ...diagnostic and treatment modalities were available. A new classification of aortic dissection in the current era may provide clinicians with a more precise method of characterizing the interaction of time, dissection location, and treatment type with survival. Methods We developed separate Kaplan-Meier survival curves for Type A and Type B aortic dissection using data from the International Registry of Aortic Dissection (IRAD). Daily survival was stratified based on type of therapy provided: medical therapy alone (medical), nonsurgical intervention plus medical therapy (endovascular), and open surgery plus medical therapy (surgical). The log-rank statistic was used to compare the survival curves of each management type within Type A and Type B aortic dissection. Results There were 1815 patients included, 67.3% male with mean age 62.0 ± 14.2 years. When survival curves were constructed, 4 distinct time periods were noted: hyperacute (symptom onset to 24 hours), acute (2-7 days), subacute (8-30 days), and chronic (>30 days). Overall survival was progressively lower through the 4 time periods. Conclusions This IRAD classification system can provide clinicians with a more robust method of characterizing survival after aortic dissection over time than previous methods. This system will be useful for treating patients, counseling patients and families, and studying new diagnostic and treatment methods.