Abstract Nonvitamin K-dependent oral anticoagulant agents (NOACs) are currently recommended for patients with atrial fibrillation at risk for stroke. As a group, NOACs significantly reduce stroke, ...intracranial hemorrhage, and mortality, with lower to similar major bleeding rates compared with warfarin. All NOACs are dependent on the kidney for elimination, such that patients with creatinine clearance <25 ml/min were excluded from all the pivotal phase 3 NOAC trials. It therefore remains unclear how or if NOACs should be prescribed to patients with advanced chronic kidney disease and those on dialysis. The authors review the current pharmacokinetic, observational, and prospective data on NOACs in patients with advanced chronic kidney disease (creatinine clearance <30 ml/min) and those on dialysis. The authors frame the evidence in terms of risk versus benefit to bring greater clarity to NOAC-related major bleeding and efficacy at preventing stroke specifically in patients with creatinine clearance <30 ml/min.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Device repositioning during Micra leadless pacemaker implantation may be required to achieve optimal pacing thresholds.
The purpose of this study was to describe the natural history of acute elevated ...Micra vs traditional transvenous lead thresholds.
Micra study VVI patients with threshold data (at 0.24 ms) at implant (n = 711) were compared with Capture study patients with de novo transvenous leads at 0.4 ms (n = 538). In both cohorts, high thresholds were defined as >1.0 V and very high as >1.5 V. Change in pacing threshold (0–6 months) with high (1.0 to ≤1.5 V) or very high (>1.5 V) thresholds were compared using the Wilcoxon signed-rank test.
Of the 711 Micra patients, 83 (11.7%) had an implant threshold of >1.0 V at 0.24 ms. Of the 538 Capture patients, 50 (9.3%) had an implant threshold of >1.0 V at 0.40 ms. There were no significant differences in patient characteristics between those with and without an implant threshold of >1.0 V, with the exception of left ventricular ejection fraction in the Capture cohort (high vs low thresholds, 53% vs 58%; P = .011). Patients with an implant threshold of >1.0 V decreased significantly (P < .001) in both cohorts. Micra patients with high and very high thresholds decreased significantly (P < .01) by 1 month, with 87% and 85% having 6-month thresholds lower than the implant value. However, when the capture threshold at implant was >2 V, only 18.2% had a threshold of ≤1 V at 6 months and 45.5% had a capture threshold of >2 V.
Pacing thresholds in most Micra patients with elevated thresholds decrease after implant. Micra device repositioning may not be necessary if the pacing threshold is ≤2 V.
Abstract Background Remote monitoring (RM) technology embedded within cardiac rhythm devices permits continuous monitoring, which may result in improved patient outcomes. Objectives This study used ...“big data” to assess whether RM is associated with improved survival and whether this is influenced by the type of cardiac device and/or its degree of use. Methods We studied 269,471 consecutive U.S. patients implanted between 2008 and 2011 with pacemakers (PMs), implantable cardioverter-defibrillators (ICDs), or cardiac resynchronization therapy (CRT) with pacing capability (CRT-P)/defibrillation capability (CRT-D) with wireless RM. We analyzed weekly use and all-cause survival for each device type by the percentage of time in RM (%TRM) stratified by age. Socioeconomic influences on %TRM were assessed using 8 census variables from 2012. Results The group had implanted PMs (n = 115,076; 43%), ICDs (n = 85,014; 32%), CRT-D (n = 61,475; 23%), and CRT-P (n = 7,906; 3%). When considered together, 127,706 patients (47%) used RM, of whom 67,920 (53%) had ≥75%TRM (high %TRM) and 59,786 (47%) <75%TRM (low %TRM); 141,765 (53%) never used RM (RM None). RM use was not affected by age or sex, but demonstrated wide geographic and socioeconomic variability. Survival was better in high %TRM versus RM None (hazard ratio HR: 2.10; p < 0.001), in high %TRM versus low %TRM (HR: 1.32; p < 0.001), and also in low %TRM versus RM None (HR: 1.58; p < 0.001). The same relationship was observed when assessed by individual device type. Conclusions RM is associated with improved survival, irrespective of device type (including PMs), but demonstrates a graded relationship with the level of adherence. The results support the increased application of RM to improve patient outcomes.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Highlights•Derangement of autonomic nervous signaling is an important contributor to cardiac arrhythmogenesis. •Modulation of autonomic nervous signaling holds significant promise for the prevention ...and treatment of cardiac arrhythmias. •Further clinical investigation is necessary to establish the efficacy and safety of autonomic modulatory therapies in reducing cardiac arrhythmias.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
With increasing indications and access to cardiac implantable electronic devices (CIEDs) worldwide, the number of patients needing CIED follow up continues to rise. In parallel, the technology ...available for managing these devices has advanced considerably. In this setting, remote monitoring (RM) has emerged as a complement to routine in-office care. Rigorous studies, randomized and otherwise, have demonstrated advantages to CIED patient management systems which incorporates RM resulting in authoritative guidelines from relevant professional societies recommending RM for all eligible patients. In addition to clinical benefits, CIED management programs that include RM have been shown to be cost effective and associated with high patient satisfaction. Finally, RM programs hold promise for the future of CIED research in light of the massive data collected through RM databases converging with unprecedented computational capability. This review outlines the available data associated with clinical outcomes in patients managed with RM with an emphasis on randomized trials; the impact of RM on patient satisfaction, cost-effectiveness and healthcare utilization; and possible future directions for the use of RM in clinical practice and research.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK, ZRSKP
Background Time in therapeutic range (TTR) of international normalized ratio (INR) of 2.0 to 3.0 is important for the safety and effectiveness of warfarin anticoagulation. There are few data on TTR ...among patients with atrial fibrillation (AF) in community-based clinical practice. Methods Using the US Outcomes Registry for Better Informed Treatment of Atrial Fibrillation (ORBIT-AF), we examined TTR (using a modified Rosendaal method) among 5,210 patients with AF on warfarin and treated at 155 sites. Patients were grouped into quartiles based on TTR data. Multivariable logistic regression modeling with generalized estimating equations was used to determine patient and provider factors associated with the lowest (worst) TTR. Results Overall, 59% of the measured INR values were between 2.0 and 3.0, with an overall mean and median TTR of 65% ± 20% and 68% (interquartile range IQR 53%-79%). The median times below and above the therapeutic range were 17% (IQR 8%-29%) and 10% (IQR 3%-19%), respectively. Patients with renal dysfunction, advanced heart failure, frailty, prior valve surgery, and higher risk for bleeding (ATRIA score) or stroke (CHA2 DS2 -VASc score) had significantly lower TTR ( P < .0001 for all). Patients treated at anticoagulation clinics had only slightly higher median TTR (69%) than those not (66%) ( P < .0001). Conclusions Among patients with AF in US clinical practices, TTR on warfarin is suboptimal, and those at highest predicted risks for stroke and bleeding were least likely to be in therapeutic range.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
Abstract Objectives This study sought to explore gender differences in real-world outcomes after catheter ablation of atrial fibrillation (AF). Background Compared with men, women with AF have ...greater thromboembolic risk and tend to be more symptomatic. Catheter ablation is generally more effective than antiarrhythmic drug therapy alone. However, there are limited data on the influence of gender on AF ablation outcomes. Methods We analyzed medical claims of 45 million U.S. patients enrolled in a variety of employee-sponsored and fee-for-service plans. We identified patients who underwent an AF ablation from 2007 to 2011 and evaluated 30-day safety and 1-year effectiveness outcomes. Results Of the 21,091 patients who underwent an AF ablation, 7,460 (29%) were female. Women, compared with men, were older (62 ± 11 years vs. 58 ± 11 years), had higher CHADS2 (1.2 ± 1.1 vs. 1.0 ± 1.0), higher CHA2 DS2 -VASc (2.9 ± 1.5 vs. 1.6 ± 1.4), and higher Charlson comorbidity index scores (1.2 ± 1.3 vs. 1.0 ± 1.2) (p < 0.001 for all). Following ablation, women had higher risk of 30-day complications of hemorrhage (2.7% vs. 2.0%; p < 0.001) and tamponade (3.8% vs. 2.9%; p < 0.001). In multivariable analyses, women were more likely to have a rehospitalization for AF (adjusted hazard ratio: 1.12; p = 0.009), but less likely to have repeat AF ablation (adjusted hazard ratio: 0.92; p = 0.04) or cardioversion (adjusted hazard ratio: 0.75; p < 0.001). Conclusions Women have increased hospitalization rates after AF ablation and are more likely to have a procedural complication. Despite the higher rate of hospital admissions for AF after ablation, women were less likely to undergo repeat ablation or cardioversion. These data call for greater examination of barriers and facilitators to sustain rhythm control strategies in women.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Objectives This study sought to investigate the outcomes following cardioversion or catheter ablation in patients with atrial fibrillation (AF) treated with warfarin or rivaroxaban. Background There ...are limited data on outcomes following cardioversion or catheter ablation in AF patients treated with factor Xa inhibitors. Methods We compared the incidence of electrical cardioversion (ECV), pharmacologic cardioversion (PCV), or AF ablation and subsequent outcomes in patients in a post hoc analysis of the ROCKET AF (Efficacy and Safety Study of Rivaroxaban With Warfarin for the Prevention of Stroke and Non-Central Nervous System Systemic Embolism in Patients With Non-Valvular Atrial Fibrillation) trial. Results Over a median follow-up of 2.1 years, 143 patients underwent ECV, 142 underwent PCV, and 79 underwent catheter ablation. The overall incidence of ECV, PCV, or AF ablation was 1.45 per 100 patient-years (n = 321; 1.44 n = 161 in the warfarin arm, 1.46 n = 160 in the rivaroxaban arm). The crude rates of stroke and death increased in the first 30 days after cardioversion or ablation. After adjustment for baseline differences, the long-term incidence of stroke or systemic embolism (hazard ratio HR: 1.38; 95% confidence interval CI: 0.61 to 3.11), cardiovascular death (HR: 1.57; 95% CI: 0.69 to 3.55), and death from all causes (HR: 1.75; 95% CI: 0.90 to 3.42) were not different before and after cardioversion or AF ablation. Hospitalization increased after cardioversion or AF ablation (HR: 2.01; 95% CI: 1.51 to 2.68), but there was no evidence of a differential effect by randomized treatment (p value for interaction = 0.58). The incidence of stroke or systemic embolism (1.88% vs. 1.86%) and death (1.88% vs. 3.73%) were similar in the rivaroxaban-treated and warfarin-treated groups. Conclusions Despite an increase in hospitalization, there were no differences in long-term stroke rates or survival following cardioversion or AF ablation. Outcomes were similar in patients treated with rivaroxaban or warfarin. (An Efficacy and Safety Study of Rivaroxaban With Warfarin for the Prevention of Stroke and Non-Central Nervous System Systemic Embolism in Patients With Non-Valvular Atrial Fibrillation ROCKET AF; NCT00403767 )
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Background The prevalence of both atrial fibrillation (AF) and diabetes mellitus (DM) are rising, and these conditions often occur together. Also, DM is an independent risk factor for stroke in ...patients with AF. We aimed to examine the safety and efficacy of rivaroxaban vs warfarin in patients with nonvalvular AF and DM in a prespecified secondary analysis of the ROCKET AF trial. Methods We stratified the ROCKET AF population by DM status, assessed associations with risk of outcomes by DM status and randomized treatment using Cox proportional hazards models, and tested for interactions between randomized treatments. For efficacy, primary outcomes were stroke (ischemic or hemorrhagic) or non–central nervous system embolism. For safety, the primary outcome was major or nonmajor clinically relevant bleeding. Results The 5,695 patients with DM (40%) in ROCKET AF were younger, were more obese, and had more persistent AF, but fewer had previous stroke (the CHADS2 score includes DM and stroke). The relative efficacy of rivaroxaban and warfarin for prevention of stroke and systemic embolism was similar in patients with (1.74 vs 2.14/100 patient-years, hazard ratio HR 0.82) and without (2.12 vs 2.32/100 patient-years, HR 0.92) DM (interaction P = .53). The safety of rivaroxaban vs warfarin regarding major bleeding (HRs 1.00 and 1.12 for patients with and without DM, respectively; interaction P = .43), major or nonmajor clinically relevant bleeding (HRs 0.98 and 1.09; interaction P = .17), and intracerebral hemorrhage (HRs 0.62 and 0.72; interaction P = .67) was independent of DM status. Adjusted exploratory analyses suggested 1.3-, 1.5-, and 1.9-fold higher 2-year rates of stroke, vascular mortality, and myocardial infarction in DM patients. Conclusions and Relevance The relative efficacy and safety of rivaroxaban vs warfarin was similar in patients with and without DM, supporting use of rivaroxaban as an alternative to warfarin in diabetic patients with AF.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
Background Obstructive sleep apnea (OSA) is common in patients with atrial fibrillation (AF). Little is known about the impact of OSA on AF treatment and long-term outcomes. We studied whether ...patients with OSA have a greater likelihood of progressing to more persistent forms of AF or require more hospitalizations and/or worse outcomes compared with patients without OSA. Methods A total of 10,132 patients were enrolled between June 2010 and August 2011 in the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation (ORBIT-AF) and followed for up to 2 years. The prevalence of OSA and continuous positive airway pressure (CPAP) treatment was captured at baseline. The association between OSA and major cardiovascular outcomes was analyzed using multivariable hierarchical logistic regression modeling and Cox frailty regression model. Results Of the 10,132 patients with AF, 1,841 had OSA. Patients with OSA were more symptomatic (22% vs 16% severe/disabling symptoms; P < .0001) and more often on rhythm control therapy (35% vs 31%; P = .0037). In adjusted analyses, patients with OSA had higher risk of hospitalization (hazard ratio HR, 1.12; 95% CI, 1.03-1.22; P = .0078), but no difference in the risks of death (HR, 0.94; 95% CI, 0.77-1.15; P = .54); the composite of CV death, myocardial infarction, and stroke/transient ischemic attack (HR, 1.07; 95% CI, 0.85-1.34; P = .57); major bleeding (HR, 1.18; 95% CI, 0.96-1.46; P = .11); or AF progression (HR, 1.06; 95% CI, 0.89-1.28; P = .51). Patients with OSA on CPAP treatment were less likely to progress to more permanent forms of AF compared with patients without CPAP (HR, 0.66; 95% CI, 0.46-0.94; P = .021). Conclusion Compared with those without, AF patients with OSA have worse symptoms and higher risks of hospitalization, but similar mortality, major adverse cardiovascular outcome, and AF progression rates. Clinical Trial Registration: NCT01165710 ( http://www.clinicaltrials.gov ).
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK