The management of patients with atrial fibrillation (AF) is often inadequate due to deficient adherence to the guidelines. A nurse-led AF clinic providing integrated chronic care to improve guideline ...adherence and activate patients in their role, may effectively reduce morbidity and mortality but such care has not been tested in a large randomized trial. Therefore, we performed a randomized clinical trial to compare the AF clinic with routine clinical care in patients with AF.
We randomly assigned 712 patients with AF to nurse-led care and usual care. Nurse-led care consisted of guidelines based, software supported integrated chronic care supervised by a cardiologist. The primary endpoint was a composite of cardiovascular hospitalization and cardiovascular death. Duration of follow-up was at least 12 months. Adherence to guideline recommendations was significantly better in the nurse-led care group. After a mean of 22 months, the primary endpoint occurred in 14.3% of 356 patients of the nurse-led care group compared with 20.8% of 356 patients receiving usual care hazard ratio: 0.65; 95% confidence interval (CI) 0.45-0.93; P= 0.017. Cardiovascular death occurred in 1.1% in the nurse-led care vs. 3.9% in the usual care group (hazard ratio: 0.28; 95% CI: 0.09-0.85; P= 0.025). Cardiovascular hospitalization amounted (13.5 vs. 19.1%, respectively, hazard ratio: 0.66; 95% CI: 0.46-0.96, P= 0.029).
Nurse-led care of patients with AF is superior to usual care provided by a cardiologist in terms of cardiovascular hospitalizations and cardiovascular mortality. Trial registration information: Clinicaltrials.gov identifier number: NCT00391872.
Objectives The purpose of this study was to evaluate the feasibility, safety, and clinical outcomes up to 1 year in patients undergoing combined simultaneous thoracoscopic surgical and transvenous ...catheter atrial fibrillation (AF) ablation. Background The combination of the transvenous endocardial approach with the thoracoscopic epicardial approach in a single AF ablation procedure overcomes the limitations of both techniques and should result in better outcomes. Methods A cohort of 26 consecutive patients with AF who underwent hybrid thoracoscopic surgical and transvenous catheter ablation were followed, with follow-up of up to 1 year. Results Twenty-six patients (42% with persistent AF) underwent successful hybrid procedures. There were no complications. The mean follow-up period was 470 ± 154 days. In 23% of the patients, the epicardial lesions were not transmural, and endocardial touch-up was necessary. One-year success, defined according to the Heart Rhythm Society, European Heart Rhythm Association, and European Cardiac Arrhythmia Society consensus statement for the catheter and surgical ablation of AF, was 93% for patients with paroxysmal AF and 90% for patients with persistent AF. Two patients underwent catheter ablation for recurrent AF or left atrial flutter after the hybrid procedure. Conclusions A combined transvenous endocardial and thoracoscopic epicardial ablation procedure for AF is feasible and safe, with a single-procedure success rate of 83% at 1 year.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
The relation between myocardial scar and different types of ventricular arrhythmias in patients with nonischemic dilated cardiomyopathy (NIDCM) is unknown.
The purpose of this study was to analyze ...the effect of myocardial scar, assessed by late gadolinium enhancement cardiac magnetic resonance imaging (LGE-CMR), on the occurrence and type of ventricular arrhythmia in patients with NIDCM.
Consecutive patients with NIDCM who underwent LGE-CMR and implantable cardioverter-defibrillator (ICD) implantation at either of 2 centers were included. LGE was defined by signal intensity ≥35% of maximal signal intensity, subdivided into core and border zones (≥50% and 35%-50% of maximal signal intensity, respectively), and categorized according to location (basal or nonbasal) and transmurality. ICD recordings and electrocardiograms were reviewed to determine the occurrence and type of ventricular arrhythmia during follow-up.
Of 87 patients (age 56 ± 13 y, 62% male, left ventricular ejection fraction 29% ± 12%), 55 (63%) had LGE (median 6.3 g, interquartile range 0.0-13.8 g). During a median follow-up of 45 months, monomorphic ventricular tachycardia (VT) occurred in 18 patients (21%) and polymorphic VT/ventricular fibrillation (VF) in 10 (11%). LGE predicted monomorphic VT (log-rank, P < .001), but not polymorphic VT/VF (log-rank, P = .40). The optimal cutoff value for the extent of LGE to predict monomorphic VT was 7.2 g (area under curve 0.84). Features associated with monomorphic VT were core extent, basal location, and area with 51%-75% LGE transmurality.
Myocardial scar assessed by LGE-CMR predicts monomorphic VT, but not polymorphic VT/VF, in NIDCM. The risk for monomorphic VT is particularly high when LGE shows a basal transmural distribution and a mass ≥7.2 g. Importantly, patients without LGE on CMR remain at risk for potentially fatal polymorphic VT/VF.
The single-step hybrid atrial fibrillation (AF) ablation procedure combines a transvenous endocardial and thoracoscopic epicardial approach in 1 procedure. Short-term results are encouraging, but ...long-term outcome data are not available.
Hybrid AF ablation was successfully performed in 64 consecutive patients (53% with persistent AF). The mean follow-up period was 1732 ± 353 days. Perprocedural endocardial touch-up of incomplete epicardial lesions was performed in 17 (26%) patients.
In paroxysmal AF patients, arrhythmia-free cumulative survival rates after 1 hybrid AF ablation without Class I or III antiarrhythmic drugs procedure and without redo catheter ablation were 83%, 80% and 80% after 1, 2 and 3 years, respectively. In (long-standing) persistent AF patients, these were 82%, 79% and 79% after 1, 2 and 3 years. Thirteen (20%) patients had at least 1 recurrent episode of supraventricular arrhythmia lasting longer than 30 s: the most frequent recurrent arrhythmias were left atrial flutter and AF. No mortality or conversion to cardiopulmonary bypass, no phrenic nerve palsy and no pacemaker implantation were reported.
Hybrid AF ablation, combining a transvenous endocardial and thoracoscopic epicardial approach in a single procedure, results in a cumulative 3-year freedom from arrhythmia without Class I or III antiarrhythmic drugs and without redo catheter ablation of 80% in paroxysmal AF (24 of 30 patients) and 79% in non-paroxysmal AF (26 of 33 patients).
The aim of this survey was to provide insight into current practice regarding ablation of persistent atrial fibrillation (AF) among members of the European Heart Rhythm Association electrophysiology ...research network. Thirty centres responded to the survey. The main ablation technique for first-time ablation was stand-alone pulmonary vein isolation (PVI): in 67% of the centres for persistent but not long-standing AF and in 37% of the centres for long-standing persistent AF as well. Other applied techniques were ablation of fractionated electrograms, placement of linear lesions, stepwise approach until AF termination, and substrate mapping and isolation of low-voltage areas. However, the percentage of centres applying these techniques during first ablation did not exceed 25% for any technique. When stand-alone PVI was performed in patients with persistent but not long-standing AF, the majority (80%) of the centres used an irrigated radiofrequency ablation catheter whereas 20% of the respondents used the cryoballoon. Similar results were reported for ablation of long-standing persistent AF (radiofrequency 90%, cryoballoon 10%). Neither rotor mapping nor one-shot ablation tools were used as the main first-time ablation methods. Systematic search for non-pulmonary vein triggers was performed only in 10% of the centres. Most common 1-year success rate off antiarrhythmic drugs was 50-60%. Only 27% of the centres knew their 5-year results. In conclusion, patients with persistent AF represent a significant proportion of AF patients undergoing ablation. There is a shift towards stand-alone PVI being the primary choice in many centres for first-time ablation in these patients. The wide variation in the use of additional techniques and in the choice of endpoints reflects the uncertainties and lack of guidance regarding the most optimal approach. Procedural success rates are modest and long-term outcomes are unknown in most centres.
To evaluate QT-interval dynamics in patients and in drug safety analysis, beat-to-beat QT-interval measurements are increasingly used. However, interobserver differences, aberrant T-wave morphologies ...and changes in heart axis might hamper accurate QT-interval measurements.
To develop and validate a QT-interval algorithm robust to heart axis orientation and T-wave morphology that can be applied on a beat-to-beat basis.
Additionally to standard ECG leads, the root mean square (ECGRMS), standard deviation and vectorcardiogram were used. QRS-onset was defined from the ECGRMS. T-wave end was defined per individual lead and scalar ECG using an automated tangent method. A median of all T-wave ends was used as the general T-wave end per beat. Supine-standing tests of 73 patients with Long-QT syndrome (LQTS) and 54 controls were used because they have wide ranges of RR and QT-intervals as well as changes in T-wave morphology and heart axis orientation. For each subject, automatically estimated QT-intervals in three random complexes chosen from the low, middle and high RR range, were compared with manually measured QT-intervals by three observers.
After visual inspection of the randomly selected complexes, 21 complexes were excluded because of evident noise, too flat T-waves or premature ventricular beats. Bland-Altman analyses of automatically and manually determined QT-intervals showed a bias of <4ms and limits of agreement of ±25ms. Intra-class coefficient indicated excellent agreement (>0.9) between the algorithm and all observers individually as well as between the algorithm and the mean QT-interval of the observers.
Our automated algorithm provides reliable beat-to-beat QT-interval assessment, robust to heart axis and T-wave morphology.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Delayed left ventricular (LV) lateral wall (LVLW) activation is considered the electrical substrate underlying LV dysfunction amenable to cardiac resynchronization therapy (CRT).
The purpose of this ...study was to assess LVLW activation in CRT candidates using coronary venous electroanatomic mapping (EAM) and to investigate whether the QRS area (QRSAREA) on the vectorcardiogram (VCG) can identify delayed LVLW activation.
Fifty-one consecutive CRT candidates (29 left bundle branch block LBBB, 15 intraventricular conduction delay IVCD, 7 right bundle branch block RBBB) underwent intraprocedural coronary venous EAM using EnSite NavX. VCGs were constructed from preprocedural digital 12-lead ECGs using the Kors method. QRSAREA was assessed and compared to QRS duration and 5 different LBBB definitions.
Delayed LVLW activation (activation time >75% of QRS duration) occurred in 38 of 51 patients (29/29 LBBB, 8/15 IVCD, 1/7 RBBB). QRSAREA was larger in patients with than in patients without delayed LVLW activation (108 ± 42 µVs vs 51 ± 27 µVs, P < .001), and identified delayed LVLW activation better than QRS duration (area under the curve 0.89 95% confidence interval 0.79-0.99 vs 0.49 95% confidence interval 0.33-0.65). QRSAREA >69 µVs diagnosed delayed LVLW activation with a higher sum of sensitivity (87%) and specificity (92%) than any of the LBBB definitions. Of the different LBBB definitions, the European Society of Cardiology textbook definition performed best with sensitivity of 76% and specificity of 100%.
Coronary venous EAM can be used during CRT implantation to determine the presence of delayed LVLW activation. QRSAREA is a noninvasive alternative for intracardiac measurements of electrical activation, which identifies delayed LVLW activation better than QRS duration and LBBB morphology.
This study aims to compare the performance of physicians to detect atrial fibrillation (AF) based on photoplethysmography (PPG), single-lead ECG and 12-lead ECG, and to explore the incremental value ...of PPG presentation as a tachogram and Poincaré plot, and of algorithm classification for interpretation by physicians.
Email invitations to participate in an online survey were distributed among physicians to analyse almost simultaneously recorded PPG, single-lead ECG and 12-lead ECG traces from 30 patients (10 in sinus rhythm (SR), 10 in SR with ectopic beats and 10 in AF). The task was to classify the readings as 'SR', 'ectopic/missed beats', 'AF', 'flutter' or 'unreadable'. Sixty-five physicians detected or excluded AF based on the raw PPG waveforms with 88.8% sensitivity and 86.3% specificity. Additional presentation of the tachogram plus Poincaré plot significantly increased sensitivity and specificity to 95.5% (
< 0.001) and 92.5% (
< 0.001), respectively. The algorithm information did not further increase the accuracy to detect AF (sensitivity 97.5%,
= 0.556; specificity 95.0%,
= 0.182). Physicians detected AF on single-lead ECG tracings with 91.2% sensitivity and 93.9% specificity. Diagnostic accuracy was also not optimal on full 12-lead ECGs (93.9 and 98.6%, respectively). Notably, there was no significant difference between the performance of PPG waveform plus tachogram and Poincaré, compared to a single-lead ECG to detect or exclude AF (sensitivity
= 0.672; specificity
= 0.536).
Physicians can detect AF on a PPG output with equivalent accuracy compared to single-lead ECG, if the PPG waveforms are presented together with a tachogram and Poincaré plot and the quality of the recordings is high.
The standard 12-lead ECG has been shown to be of value in characterizing atrial conduction properties. The added value of extended ECG recordings (longer recordings from more sites) has not been ...systematically explored yet.
The aim of this study is to employ an extended ECG to identify characteristics of atrial electrical activity related to paroxysmal vs. persistent atrial fibrillation (AF).
In 247 participants scheduled for AF ablation, an extended ECG was recorded (12 standard plus 3 additional leads, 5 min recording, no filtering). For patients presenting in sinus rhythm (SR), the signal-averaged P-wave and the spatiotemporal P-wave variability was analyzed. For patients presenting in AF, f-wave properties in the QRST (the amplitude complex of the ventricular electrical activity: Q-, R-, S-, and T-wave)-canceled ECG were determined.
Significant differences between paroxysmal (
= 152) and persistent patients with AF (
= 95) were found in several P-wave and f-wave parameters, including parameters that can only be calculated from an extended ECG. Furthermore, a moderate, but significant correlation was found between echocardiographic parameters and P-wave and f-wave parameters. There was a moderate correlation of left atrial (LA) diameter with P-wave energy duration (
= 0.317,
< 0.001) and f-wave amplitude in lead A3 (
= -0.389,
= 0.002). The AF-type classification performance significantly improved when parameters calculated from the extended ECG were taken into account area under the curve (AUC) = 0.58, interquartile range (IQR) 0.50-0.64 for standard ECG parameters only vs. AUC = 0.76, IQR 0.70-0.80 for extended ECG parameters,
< 0.001.
The P- and f-wave analysis of extended ECG configurations identified specific ECG features allowing improved classification of paroxysmal vs. persistent AF. The extended ECG significantly improved AF-type classification in our analyzed data as compared to a standard 10-s 12-lead ECG. Whether this can result in a better clinical AF type classification warrants further prospective study.