Gamma ray spectrometry measurements at high detector counting rates (on the order of 107 s−1 and higher) are relevant for high-temperature plasma diagnostics for existing tokamaks and during the ...development of gamma ray diagnostic systems for the ITER tokamak under construction. At high loads, to obtain spectra without distortion and with a small amount of dead time, it is necessary to use advanced scintillation detector signal processing methods, which can resolve superimposed pulses. Two algorithms that can be used for digital signal processing of scintillation gamma ray detectors with many piled-up pulses are considered in this article, the fitting and deconvolution methods. These algorithms are compared with both one another and two less sophisticated pulse-height analysis algorithms (maximum height and total sum under the peak) in applications that process model and measured signals. Baseline detection algorithms are also considered, which are necessary when processing signals from detectors. The algorithms are applied to LaBr3(Ce) detector signal processing. For the modeled signals, the best results in terms of the number of resolved events and energy resolution at counting rates up to 2 × 107 s−1 of the LaBr3(Ce) detector are demonstrated by the fitting method. In the real gamma ray measurements at a loading of 5.1 106 s−1, the deconvolution method demonstrated the best energy resolution.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Two neutron spectrometers based on a BC-501A liquid organic scintillator were calibrated. The calibration procedure included obtaining the spectrometers’ response functions to monoenergetic neutron ...emissions and estimating the detectors’ efficiency and is described in this paper. A 9Be(α, nγ)12C nuclear reaction was used as the neutron source. Simultaneous registration of neutrons and gamma quanta with 4.44 MeV energy enabled the extraction of monoenergetic neutrons corresponding to the first excited state of a 12C nucleus. This process is the basis of the neutron–gamma coincidence method, which was applied in the present experiments. The experiments were conducted using the cyclotron at Ioffe Institute, where α particles were accelerated to energies of 2.06, 5.35, 6.05, and 10.08 MeV. The angular dependence of the energy of produced neutrons provided a wide energy range of monoenergetic neutron emission at the same energy of the incident α particle. The response functions of the BC-501A spectrometers on the monoenergetic neutrons were obtained at energies of 1.9 to 10.4 MeV. The neutron registration efficiency of both detectors was estimated in the same energy range as the responses.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
A project of a gamma-ray spectrometric system for diagnosing fast particles in the TRT tokamak plasma is described. The organizational concept of gamma spectrometric measurements is proposed. ...Preliminary results of calculating the intensities of gamma ray lines of hydrogen, deuterium, and deuterium–tritium plasmas are presented, which demonstrate the possibility of obtaining information about the energy and spatial distribution of fast ions with a time resolution of 1–10 s when using a multidetector system. Runaway electrons can be observed by hard X-ray emission from the tokamak plasma in the megaelectronvolt range.
Full text
Available for:
DOBA, EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, IZUM, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, SIK, UILJ, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
4.
Neutron diagnostic system at the Globus-M2 tokamak Iliasova, M.V.; Shevelev, A.E.; Khilkevitch, E.M. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
04/2022, Volume:
1029
Journal Article
Peer reviewed
A neutron diagnostic system was developed at the Ioffe Institute as part of the Globus-M2 tokamak to optimize NBI heating conditions and evaluate heating efficiency. The system contains two compact ...neutron spectrometers based on the liquid organic scintillator BC-501A and two gas-discharge counters based on a 10B isotope. The BC-501A spectrometers were calibrated by measuring neutron emission produced in a 9Be(α,n)12C nuclear reaction on the cyclotron facility at the Ioffe Institute. In addition, in situ calibrations of the system, including the neutron spectrometers and the gas-discharge counters, was carried out using an Am–Be neutron source to provide accurate measurements of the total neutron yield from the plasma of the Globus-M2 tokamak. During the plasma experiments at the Globus-M2 tokamak, a deuterium beam was injected into the deuterium plasma that causes a yield of the DD-neutrons with ∼2.45 MeV energy. The neutron spectrometry diagnostic system was used to provide neutron measurements and detect the DD-neutrons in these experiments. The neutron yield and the DD-reaction rate during plasma discharges were evaluated. The energy distributions of neutrons emitted from plasma during discharges with neutron beam injection were reconstructed from the measured neutron spectra.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK, ZRSKP
Mycobacterium tuberculosis
cells contain two apurinic/apyrimidinic (AP) endonucleases, endonuclease IV (MtbEnd) and exonuclease III (MtbXthA), the former playing a dominant role in protecting ...mycobacterial DNA from oxidative stress. Mycobacterial endonuclease IV substantially differs from its homologs found in
Escherichia coli
and other proteobacteria in a number of conserved positions important for DNA binding and AP site recognition. The
M. tuberculosis end
gene was cloned, and recombinant MtbEnd purified and characterized. The protein efficiently hydrolyzed DNA at the natural AP site and its 1′-deoxy analog in the presence of divalent cations, of which Ca
2+
, Mn
2+
, and Co
2+
supported the highest activity. Exonuclease activity was not detected in MtbEnt preparations. The pH optimum was estimated at 7.0–8.0; the ionic strength optimum, at ~50 mM NaCl. Enzymatic activity of MtbEnd was suppressed in the presence of methoxyamine, a chemotherapeutic agent that modifies AP sites. Based on the results, MtbEnd was assumed to provide a possible target for new anti-tuberculosis drugs.
Full text
Available for:
EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
A gamma-ray spectrometer based on LaBr3(Ce) scintillator has been used for measurements of hard X-ray emission generated by runaway electrons in the FT-2 tokamak plasmas. Using of the fast LaBr3(Ce) ...has allowed extending count rate range of the spectrometer by a factor of 10. A developed digital processing algorithm of the detector signal recorded with a digitizer sampling rate of 250MHz has provided a pulse height analysis at count rates up to 107s−1. A spectrum deconvolution code DeGaSum has been applied for inferring the energy distribution of runaway electrons escaping from the plasma and interacting with materials of the FT-2 limiter in the vacuum chamber. The developed digital signal processing technique for LaBr3(Ce) spectrometer has allowed studying the evolution of runaways energy distribution in the FT-2 plasma discharges with time resolution of 1–5ms.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK, ZRSKP
Studies of the super-thermal and runaway electron behavior in ohmic and lower hybrid current drive FT-2 tokamak plasmas have been carried out using information obtained from measurements of hard ...x-ray spectra and non-thermal microwave radiation intensity at the frequency of 10 GHz and in the range of (53 ÷ 78) GHz. A gamma-ray spectrometer based on a scintillation detector with a LaBr3(Ce) crystal was used, which provides measurements at counting rates up to 107 s−1. Reconstruction of the energy distribution of RE interacting with the poloidal limiter of the tokamak chamber was made with application of the DeGaSum code. Super-thermal electrons accelerated up to 2 MeV by the LH waves at the high-frequency pumping of the plasma with low density 〈ne〉 ~ 2 × 1013 cm−3 and then up to 7 MeV by vortex electric field have been found. Experimental analysis of the runaway electron beam generation and evolution of their energy distribution in the FT-2 plasmas is presented in the article and compared with the numerical calculation of the maximum energy gained by runaway electrons for given plasma parameters. In addition, possible mechanisms for limiting the maximum energy gained by the runaway electrons are also calculated and described for a FT-2 plasma discharge.
We present the measured spectra of γ and neutron radiation generated in the
9
Be(
3
He,
p
γ)
11
B and
9
Be(
3
He,
n
γ)
11
C nuclear reactions at an energy of 2.57 MeV of
3
He ions using a BC-501A ...organic detector and an HPGe semiconductor spectrometer. Line shapes of 6.9-MeV γ-transitions from the
9
Be(
3
He,
n
γ)
11
C reaction and 8.92-MeV transitions from the
9
Be(
3
He,
p
γ)
11
B reaction, measured at angles of 0°, 30°, 60°, 90°, and 120° have been determined. The angular distribution of protons emitted when populating the 8.92-MeV level of the
11
B nucleus in
9
Be(
3
He,
p
γ)
11
B reaction, as well as the energy distribution of neutrons in
9
Be(
3
He,
n
γ)
11
C reaction, have been reconstructed.
Full text
Available for:
DOBA, EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, IZUM, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, SIK, UILJ, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
Recent research at three small tokamaks with different parameters located at the Ioffe Institute-the spherical tokamak Globus-M, the large aspect ratio tokamak FT-2 and the compact tokamak ...TUMAN-3M-are reviewed. This overview covers energy confinement (Globus-M and FT-2), L-H transition (TUMAN-3M and FT-2), Alfvén waves (Globus-M and TUMAN-3M), ion cyclotron emission (TUMAN-3M), major plasma discharge disruption (Globus-M) and scrape-off layer (Globus-M) studies. A full-f global gyrokinetic modeling benchmark using synthetic diagnostics in FT-2 is described. Anomalous absorption and emission in electron cyclotron resonance heating experiments due to the parametric excitation of localized upper hybrid waves are analyzed theoretically. Progress in the development of the neutral particle analysis, gamma-ray spectrometry and divertor Thomson scattering combined with laser-induced fluorescence diagnostics for ITER is discussed. The status of the new Globus-M2 spherical tokamak is reported.
Mycobacterium tuberculosis cells contain two apurinic/apyrimidinic (AP) endonucleases, endonuclease IV (MtbEnd) and exonuclease III (MtbXthA), the former playing a dominant role in protecting ...mycobacterial DNA from oxidative stress. Mycobacterial endonuclease IV substantially differs from its homologs found in Escherichia coli and other proteobacteria in a number of conserved positions important for DNA binding and AP site recognition. The M. tuberculosis end gene was cloned, and recombinant MtbEnd purified and characterized. The protein efficiently hydrolyzed DNA at the natural AP site and its 1'-deoxy analog in the presence of divalent cations, of which Ca^(2+), Mn^(2+), and Co^(2+) supported the highest activity. Exonuclease activity was not detected in MtbEnt preparations. The pH optimum was estimated at 7.0-8.0; the ionic strength optimum, at ~50 mM NaCl. Enzymatic activity of MtbEnd was suppressed in the presence of methoxyamine, a chemotherapeutic agent that modifies AP sites. Based on the results, MtbEnd was assumed to provide a possible target for new anti-tuberculosis drugs.