The STEREO experiment Allemandou, N.; Almazán, H.; Sanchez, P. del Amo ...
Journal of instrumentation,
07/2018, Volume:
13, Issue:
7
Journal Article
Peer reviewed
Open access
The STEREO experiment is a very short baseline reactor antineutrino experiment aiming at testing the hypothesis of light sterile neutrinos as an explanation of the deficit of the observed neutrino ...interaction rate with respect to the predicted rate, known as the Reactor Antineutrino Anomaly. The detector center is located 10 m away from the compact, highly 235U enriched core of the research nuclear reactor of the Institut Laue Langevin in Grenoble, France. This paper describes the STEREO site, the detector components and associated shielding designed to suppress the external sources of background which were characterized on site. It reports the performances in terms of detector response and energy reconstruction.
The steadily increasing luminosity of the LHC requires an upgrade with high-rate and high-resolution detector technology for the inner end cap of the ATLAS muon spectrometer: the New Small Wheels ...(NSW). In order to achieve the goal of precision tracking at a hit rate of about 15 kHz/cm2 at the inner radius of the NSW, large area Micromegas quadruplets with 100µm spatial resolution per plane have been produced. IRFU, from the CEA research center of Saclay, is responsible for the production and validation of LM1 Micromegas modules. The construction, production, qualification and validation of the largest Micromegas detectors ever built are reported here. Performance results under cosmic muon characterization will also be discussed.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
MINOS is a new apparatus dedicated to in-beam nuclear structure experiments with low-intensity exotic beams in inverse kinematics at intermediate energies above 150MeV/nucleon. The device is composed ...of a thick liquid-hydrogen target coupled to a compact time projection chamber (TPC) serving as a vertex tracker. Either used for in-beam gamma spectroscopy of bound excited states or invariant-mass spectroscopy of unbound states, MINOS aims at improving the luminosity by a very significant factor compared to standard solid-target material experiments while improving experimental resolutions.
Full text
Available for:
DOBA, EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, IZUM, KILJ, KISLJ, MFDPS, NLZOH, NUK, OBVAL, OILJ, PILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, SIK, UILJ, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
4.
ANTARES: The first undersea neutrino telescope Ageron, M.; Anghinolfi, M.; Ardid, M. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
11/2011, Volume:
656, Issue:
1
Journal Article
Peer reviewed
Open access
The ANTARES Neutrino Telescope was completed in May 2008 and is the first operational Neutrino Telescope in the Mediterranean Sea. The main purpose of the detector is to perform neutrino astronomy ...and the apparatus also offers facilities for marine and Earth sciences. This paper describes the design, the construction and the installation of the telescope in the deep sea, offshore from Toulon in France. An illustration of the detector performance is given.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
Originally designed as a new nuclear reactor monitoring device, the Nucifer detector has successfully detected its first neutrinos. We provide the second-shortest baseline measurement of the reactor ...neutrino flux. The detection of electron antineutrinos emitted in the decay chains of the fission products, combined with reactor core simulations, provides a new tool to assess both the thermal power and the fissile content of the whole nuclear core and could be used by the International Agency for Atomic Energy to enhance the safeguards of civil nuclear reactors. Deployed at only 7.2 m away from the compact Osiris research reactor core (70 MW) operating at the Saclay research center of the French Alternative Energies and Atomic Energy Commission, the experiment also exhibits a well-suited configuration to search for a new short baseline oscillation. We report the first results of the Nucifer experiment, describing the performances of the ~0.85m3 detector remotely operating at a shallow depth equivalent to ~12m of water and under intense background radiation conditions. Based on 145 (106) days of data with the reactor on (off), leading to the detection of an estimated 40760nu sub(e), the mean number of detected antineutrinos is 281+ or -7(stat)+ or -18(syst)nu sub(e)/day, in agreement with the prediction of 277+ or -23nu sub(e)/day. Because of the large background, no conclusive results on the existence of light sterile neutrinos could be derived, however. As a first societal application we quantify how antineutrinos could be used for the Plutonium Management and Disposition Agreement.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
Tracking with the MINOS Time Projection Chamber Santamaria, C.; Obertelli, A.; Ota, S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
10/2018, Volume:
905
Journal Article
Peer reviewed
We report on the performance of the MINOS Time Projection Chamber developed as a vertex tracker to study exotic nuclei produced from hydrogen-induced knockout via in-beam γ-ray and invariant-mass ...spectroscopy. In-beam measurements with 4He and 20Ne beams at 200 and 350 MeV/nucleon, respectively, were performed at the HIMAC facility. The tracking algorithm for protons after quasi-free scattering is described. Realistic simulations and physics experiments are compared and show a good agreement. The vertex position resolution reaches 5 mm FWHM, mostly from re-scattering with the target and the Aluminum reaction chamber. The overall efficiency of vertex reconstruction is also benchmarked with the first experimental campaign data performed at the RIBF, confirming an overall efficiency better than 90% for physics experiments.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK, ZRSKP
The steadily increasing luminosity of the LHC requires an upgrade with high-rate and high-resolution detector technology for the inner end cap of the ATLAS muon spectrometer: the New Small Wheels ...(NSW). In order to achieve the goal of precision tracking at a hit rate of about 15 kHz/cm\(^2\) at the inner radius of the NSW, large area Micromegas quadruplets with 100\,\microns spatial resolution per plane have been produced. % IRFU, from the CEA research center of Saclay, is responsible for the production and validation of LM1 Micromegas modules. The construction, production, qualification and validation of the largest Micromegas detectors ever built are reported here. Performance results under cosmic muon characterisation will also be discussed.
The STEREO Experiment Allemandou, N; Almazán, H; del Amo Sanchez, P ...
arXiv.org,
08/2018
Paper, Journal Article
Open access
The STEREO experiment is a very short baseline reactor antineutrino experiment aiming at testing the hypothesis of light sterile neutrinos as an explanation of the deficit of the observed neutrino ...interaction rate with respect to the predicted rate, known as the Reactor Antineutrino Anomaly. The detector center is located 10 m away from the compact, highly \(^{235}\)U enriched core of the research nuclear reactor of the Institut Laue Langevin in Grenoble, France. This paper describes the STEREO site, the detector components and associated shielding designed to suppress the external sources of background which were characterized on site. It reports the performances in terms of detector response and energy reconstruction.
The growing exposure to magnetic fields of a certain intensity could represent a serious hazard for our health. In the present note we analyze the effect of a 740 Gauss magnetic field on human ...lymphocyte cell cultures. From the analysis of our data it is possible to point out that this field produces an inhibition of the cell growth, while does not affect at all the sister chromatid exchange frequency of the chromosomes. Conversely we found a significant increase of chromosome aberrations in the exposed cells. The chromosome aberrations found were mostly gaps and breaks.
Originally designed as a new nuclear reactor monitoring device, the Nucifer detector has successfully detected its first neutrinos. We provide the second shortest baseline measurement of the reactor ...neutrino flux. The detection of electron antineutrinos emitted in the decay chains of the fission products, combined with reactor core simulations, provides an new tool to assess both the thermal power and the fissile content of the whole nuclear core and could be used by the Inter- national Agency for Atomic Energy (IAEA) to enhance the Safeguards of civil nuclear reactors. Deployed at only 7.2m away from the compact Osiris research reactor core (70MW) operating at the Saclay research centre of the French Alternative Energies and Atomic Energy Commission (CEA), the experiment also exhibits a well-suited configuration to search for a new short baseline oscillation. We report the first results of the Nucifer experiment, describing the performances of the 0.85m3 detector remotely operating at a shallow depth equivalent to 12m of water and under intense background radiation conditions. Based on 145 (106) days of data with reactor ON (OFF), leading to the detection of an estimated 40760 electron antineutrinos, the mean number of detected antineutrinos is 281 +- 7(stat) +- 18(syst) electron antineutrinos/day, in agreement with the prediction 277(23) electron antineutrinos/day. Due the the large background no conclusive results on the existence of light sterile neutrinos could be derived, however. As a first societal application we quantify how antineutrinos could be used for the Plutonium Management and Disposition Agreement.