We present an apparatus for detection of cyclotron radiation yielding a frequency-based β± kinetic energy determination in the 5 keV to 2.1 MeV range, characteristic of nuclear β decays. The ...cyclotron frequency of the radiating β particles in a magnetic field is used to determine the β energy precisely. Our work establishes the foundation to apply the cyclotron radiation emission spectroscopy (CRES) technique, developed by the Project 8 Collaboration, far beyond the 18-keV tritium endpoint region. We report initial measurements of β–’s from 6He and β+’s from 19Ne decays to demonstrate the broadband response of our detection system and assess potential systematic uncertainties for β spectroscopy over the full (MeV) energy range. To our knowledge, this is the first direct observation of cyclotron radiation from individual highly relativistic β’s in a waveguide. Furthermore, this work establishes the application of CRES to a variety of nuclei, opening its reach to searches for new physics beyond the TeV scale via precision β-decay measurements.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
Autoantibodies may be present in a variety of underlying cancers several years before tumours can be detected and testing for their presence may allow earlier diagnosis. We report the clinical ...validation of an autoantibody panel in newly diagnosed patients with lung cancer (LC).
Three cohorts of patients with newly diagnosed LC were identified: group 1 (n = 145), group 2 (n = 241) and group 3 (n = 269). Patients were individually matched by gender, age and smoking history to a control individual with no history of malignant disease. Serum samples were obtained after diagnosis but before any anticancer treatment. Autoantibody levels were measured against a panel of six tumour-related antigens (p53, NY-ESO-1, CAGE, GBU4-5, Annexin 1 and SOX2). Assay sensitivity was tested in relation to demographic variables and cancer type/stage.
The autoantibody panel demonstrated a sensitivity/specificity of 36%/91%, 39%/89% and 37%/90% in groups 1, 2 and 3, respectively, with good reproducibility. There was no significant difference between different LC stages, indicating that the antigens included covered the different types of LC well.
This assay confirms the value of an autoantibody panel as a diagnostic tool and offers a potential system for monitoring patients at high risk of LC.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
It has been understood since 1897 that accelerating charges must emit electromagnetic radiation. Although first derived in 1904, cyclotron radiation from a single electron orbiting in a magnetic ...field has never been observed directly. We demonstrate single-electron detection in a novel radio-frequency spectrometer. The relativistic shift in the cyclotron frequency permits a precise electron energy measurement. Precise beta electron spectroscopy from gaseous radiation sources is a key technique in modern efforts to measure the neutrino mass via the tritium decay end point, and this work demonstrates a fundamentally new approach to precision beta spectroscopy for future neutrino mass experiments.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
We present new limits on exotic keV-scale physics based on 478 kg d of Majorana Demonstrator commissioning data. Constraints at the 90% confidence level are derived on bosonic dark matter (DM) and ...solar axion couplings, Pauli exclusion principle violating (PEPV) decay, and electron decay using monoenergetic peak signal limits above our background. Our most stringent DM constraints are set for 11.8 keV mass particles, limiting g_{Ae}<4.5×10^{-13} for pseudoscalars and (α^{'}/α)<9.7×10^{-28} for vectors. We also report a 14.4 keV solar axion coupling limit of g_{AN}^{eff}×g_{Ae}<3.8×10^{-17}, a 1/2β^{2}<8.5×10^{-48} limit on the strength of PEPV electron transitions, and a lower limit on the electron lifetime of τ_{e}>1.2×10^{24} yr for e^{-}→ invisible.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
Beta Decay of Molecular Tritium Lin, Y.-T.; Burritt, T. H.; Claessens, C. ...
Physical review letters,
06/2020, Volume:
124, Issue:
22
Journal Article
Peer reviewed
Open access
The beta decay of tritium in the form of molecular T2 is the basis of sensitive experiments to measure neutrino mass. The final-state electronic, vibrational, and rotational excitations modify the ...beta spectrum significantly and are obtained from theory. We report measurements of the branching ratios to specific ionization states for the isotopolog HT. Two earlier, concordant measurements gave branching ratios of HT to the bound HHe+ ion of 89.5% and 93.2%, in sharp disagreement with the theoretical prediction of 55%–57%, raising concerns about the theory's reliability in neutrino mass experiments. Our result, 56.5(6)%, is compatible with the theoretical expectation and disagrees strongly with the previous measurements.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
Abstract
We present the results of the first, deep Atacama Large Millimeter Array (ALMA) imaging covering the full ≃4.5 arcmin2 of the Hubble Ultra Deep Field (HUDF) imaged with Wide Field Camera ...3/IR on HST. Using a 45-pointing mosaic, we have obtained a homogeneous 1.3-mm image reaching σ1.3 ≃ 35 μJy, at a resolution of ≃0.7 arcsec. From an initial list of ≃50 > 3.5σ peaks, a rigorous analysis confirms 16 sources with S
1.3 > 120 μJy. All of these have secure galaxy counterparts with robust redshifts (〈z〉 = 2.15). Due to the unparalleled supporting data, the physical properties of the ALMA sources are well constrained, including their stellar masses (M
*) and UV+FIR star formation rates (SFR). Our results show that stellar mass is the best predictor of SFR in the high-redshift Universe; indeed at z ≥ 2 our ALMA sample contains seven of the nine galaxies in the HUDF with M
* ≥ 2 × 1010 M⊙, and we detect only one galaxy at z > 3.5, reflecting the rapid drop-off of high-mass galaxies with increasing redshift. The detections, coupled with stacking, allow us to probe the redshift/mass distribution of the 1.3-mm background down to S
1.3 ≃ 10 μJy. We find strong evidence for a steep star-forming ‘main sequence’ at z ≃ 2, with SFR ∝M
* and a mean specific SFR ≃ 2.2 Gyr−1. Moreover, we find that ≃85 per cent of total star formation at z ≃ 2 is enshrouded in dust, with ≃65 per cent of all star formation at this epoch occurring in high-mass galaxies (M
* > 2 × 1010 M⊙), for which the average obscured:unobscured SF ratio is ≃200. Finally, we revisit the cosmic evolution of SFR density; we find this peaks at z ≃ 2.5, and that the star-forming Universe transits from primarily unobscured to primarily obscured at z ≃ 4.
The Baksan Experiment on Sterile Transitions (BEST) was designed to investigate the deficit of electron neutrinos νe observed in previous gallium-based radiochemical measurements with high-intensity ...neutrino sources, commonly referred to as the "gallium anomaly," which could be interpreted as evidence for oscillations between νe and sterile neutrino (νs) states. A 3.414-MCi 51Cr νe source was placed at the center of two nested Ga volumes and measurements were made of the production of 71Ge through the charged current reaction, 71Ga(νe,e-)71Ge, at two average distances. The measured production rates for the inner and the outer targets, respectively, are 54.9$_{-2.4}^{+2.5}$(stat)±1.4(syst) and 55.6$_{-2.6}^{+2.7}$(stat)±1.4(syst) atoms of 71Ge/d. The ratio (R) of the measured rate of 71Ge production at each distance to the expected rate from the known cross section and experimental efficiencies are Rin=0.79±0.05 and Rout=0.77±0.05. The ratio of the outer to the inner result is 0.97±0.07, which is consistent with unity within uncertainty. The rates at each distance were found to be similar, but 20%-24% lower than expected, thus reaffirming the anomaly. Therefore these results are consistent with νe→νs oscillations with a relatively large Δm2 (> 0.5 eV2) and mixing sin22θ (≈0.4).
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
We present the idea and proof of principle measurements for an angular-selective active filter for charged particles. The motivation for the setup arises from the need to distinguish background ...electrons from signal electrons in a spectrometer of MAC-E filter type. While a large fraction of the background electrons exhibit predominantly small angles relative to the magnetic guiding field (corresponding to a low amount of kinetic energy in the motion component transverse to the field lines, in the following referred to as transverse energy) and pass the filter mostly unhindered, signal electrons from an isotropically emitting source interact with the active filter and are detected. The concept is demonstrated using a microchannel plate (MCP) as an active filter element. When correctly aligned with the magnetic field, electrons with a small transverse energy pass the channels of the MCP without interaction while electrons with large transverse energies hit the channel walls and trigger an avalanche of secondary electrons that is subsequently detected. Due to several drawbacks of MCPs for an actual transverse energy filter, an alternative detection technique using microstructured Si-PIN diodes is proposed.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The Majorana Demonstrator is an ultralow-background experiment searching for neutrinoless double-beta decay in ^{76}Ge. The heavily shielded array of germanium detectors, placed nearly a mile ...underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. Free, relativistic, lightly ionizing particles with an electrical charge less than e are forbidden by the standard model but predicted by some of its extensions. If such particles exist, they might be detected in the Majorana Demonstrator by searching for multiple-detector events with individual-detector energy depositions down to 1 keV. This search is background-free, and no candidate events have been found in 285 days of data taking. New direct-detection limits are set for the flux of lightly ionizing particles for charges as low as e/1000.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM