We present 25 arcsecond resolution radio images of five Lynds Dark Nebulae (L675, L944, L1103, L1111 & L1246) at 16 GHz made with the Arcminute Microkelvin Imager (AMI) Large Array. These objects ...were previously observed with the AMI Small Array to have an excess of emission at microwave frequencies relative to lower frequency radio data. In L675 we find a flat spectrum compact radio counterpart to the 850 micron emission seen with SCUBA and suggest that it is cm-wave emission from a previously unknown deeply embedded young protostar. In the case of L1246 the cm-wave emission is spatially correlated with 8 micron emission seen with Spitzer. Since the MIR emission is present only in Spitzer band 4 we suggest that it arises from a population of PAH molecules, which also give rise to the cm-wave emission through spinning dust emission.
Observations at 14.2 to 17.9 GHz made with the AMI Small Array towards fourteen Lynds Dark Nebulae with a resolution of 2' are reported. These sources are selected from the SCUBA observations of ...Visser et al. (2001) as small angular diameter clouds well matched to the synthesized beam of the AMI Small Array. Comparison of the AMI observations with radio observations at lower frequencies with matched uv-plane coverage is made, in order to search for any anomalous excess emission which can be attributed to spinning dust. Possible emission from spinning dust is identified as a source within a 2' radius of the Scuba position of the Lynds dark nebula, exhibiting an excess with respect to lower frequency radio emission. We find five sources which show a possible spinning dust component in their spectra. These sources have rising spectral indices in the frequency range 14.2--17.9 GHz. Of these five one has already been reported, L1111, we report one new definite detection, L675, and three new probable detections (L944, L1103 and L1246). The relative certainty of these detections is assessed on the basis of three criteria: the extent of the emission, the coincidence of the emission with the Scuba position and the likelihood of alternative explanations for the excess. Extended microwave emission makes the likelihood of the anomalous emission arising as a consequence of a radio counterpart to a protostar or a proto-planetary disk unlikely. We use a 2' radius in order to be consistent with the IRAS identifications of dark nebulae (Parker 1988), and our third criterion is used in the case of L1103 where a high flux density at 850 microns relative to the FIR data suggests a more complicated emission spectrum.
We present follow-up observations of 97 point sources from the Wilkinson Microwave Anisotropy Probe (WMAP) 3-year data, contained within the New Extragalactic WMAP Point Source (NEWPS) catalogue ...between declinations of -4 and +60 degrees; the sources form a flux-density-limited sample complete to 1.1 Jy (approximately 5 sigma) at 33 GHz. Our observations were made at 16 GHz using the Arcminute Microkelvin Imager (AMI) and at 33 GHz with the Very Small Array (VSA). 94 of the sources have reliable, simultaneous -- typically a few minutes apart -- observations with both telescopes. The spectra between 13.9 and 33.75 GHz are very different from those of bright sources at low frequency: 44 per cent have rising spectra (alpha < 0.0), where flux density is proportional to frequency^-alpha, and 93 per cent have spectra with alpha < 0.5; the median spectral index is 0.04. For the brighter sources, the agreement between VSA and WMAP 33-GHz flux densities averaged over sources is very good. However, for the fainter sources, the VSA tends to measure lower values for the flux densities than WMAP. We suggest that the main cause of this effect is Eddington bias arising from variability.
Using the Arcminute Microkelvin Imager (AMI) at 16 GHz and the Very Small Array (VSA) at 33 GHz to make follow-up observations of sources in the New Extragalactic WMAP Point Source Catalogue, we have ...investigated the flux-density variability in a complete sample of 97 sources over timescales of a few months to approximately 1.5 years. We find that 53 per cent of the 93 sources, for which we have multiple observations, are variable, at the 99 per cent confidence level, above the flux density calibration uncertainties of approximately 4 per cent at 16 GHz; the fraction of sources having varied by more than 20 per cent is 15 per cent at 16 GHz and 20 per cent at 33 GHz. Not only is this common occurrence of variability at high frequency of interest for source physics, but strategies for coping with source contamination in CMB work must take this variability into account. There is no strong evidence of a correlation between variability and flux density for the sample as a whole. Using a maximum-likelihood method, we calculate the correlation in the variability at the two frequencies in a subset of sources classified as variable from both the AMI and VSA data and find the Pearson product-moment correlation coefficient to be very high (0.955 +/- 0.034). We also find the degree of variability at 16 GHz (0.202 +/- 0.028) to be very similar to that at 33 GHz (0.224 +/- 0.039). Finally, we have investigated the relationship between variability and spectral index, alpha_13.9^33.75 (where S proportional to nu^-alpha), and find a significant difference in the spectral indices of the variable sources (-0.06 +/- 0.05) and non-variable sources (0.13 +/- 0.04).
•Acquisition and management of spatial information are crucial for water modelling.•Several geomatic methods of different nature arise at the service of water modelling.•Choosing the right geomatic ...method is still a challenge in this field.•This study provides a guide and review to best practices of geomatic methods.•A suitability assessment is made driven by geometric and radiometric variables.
Acquisition, management and/or use of spatial information are crucial for the quality of water resources studies. In this sense, several geomatic methods arise at the service of water modelling, aiming the generation of cartographic products, especially in terms of 3D models and orthophotos. They may also perform as tools for problem solving and decision making. However, choosing the right geomatic method is still a challenge in this field. That is mostly due to the complexity of the different applications and variables involved for water resources management. This study is aimed to provide a guide to best practices in this context by tackling a deep review of geomatic methods and their suitability assessment for the following study types: Surface Hydrology, Groundwater Hydrology, Hydraulics, Agronomy, Morphodynamics and Geotechnical Processes. This assessment is driven by several decision variables grouped in two categories, classified depending on their nature as geometric or radiometric. As a result, the reader comes with the best choice/choices for the method to use, depending on the type of water resources modelling study in hand.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
Our aim was to investigate if genetic variations in the visfatin gene (SNPs rs7789066/ rs11977021/rs4730153) could modify the cardiovascular-risk (CV-risk) despite the metabolic phenotype (obesity ...and glucose tolerance). In addition, we investigated the relationship between insulin sensitivity and variations in visfatin gene.
A population-based study in rural and urban areas of the Province of Segovia, Spain, was carried out in the period of 2001-2003 years. A total of 587 individuals were included, 25.4% subjects were defined as obese (BMI ≥30 Kg/m2).
Plasma visfatin levels were significantly higher in obese subjects with DM2 than in other categories of glucose tolerance. The genotype AA of the rs4730153 SNP was significantly associated with fasting glucose, fasting insulin and HOMA-IR (Homeostasis model assessment-insulin resistance) after adjustment for gender, age, BMI and waist circumference. The obese individuals carrying the CC genotype of the rs11977021 SNP showed higher circulating levels of fasting proinsulin after adjustment for the same variables. The genotype AA of the rs4730153 SNP seems to be protective from CV-risk either estimated by Framingham or SCORE charts in general population; and in obese and non-obese individuals. No associations with CV-risk were observed for other studied SNPs (rs11977021/rs7789066).
In summary, this is the first study which concludes that the genotype AA of the rs4730153 SNP appear to protect against CV-risk in obese and non-obese individuals, estimated by Framingham and SCORE charts. Our results confirm that the different polymorphisms in the visfatin gene might be influencing the glucose homeostasis in obese individuals.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
INTRODUCTIONHaemofiltration paradigms used to manage critically ill patients with a dysregulated inflammatory response (DIR) assess kidney function to monitor its onset, adaptation, and completion. A ...Continuous Venous Hyperfiltration (CONVEHY) protocol is presented, in which a non-specific adsorption membrane (AN69-ST-Heparin Grafted) is used with citrate as an anticoagulant and substitution fluid. CONVEHY uses tools readily available to achieve kidney related and non-related objectives, and it is guided by the monitoring of pathophysiological responses. OBJECTIVESTo compare the response to an AN69-ST-HG membrane when heparin (He, n=5: Standard protocol) or citrate (Ci, n=6: CONVEHY protocol) was used to evaluate whether a larger study into the benefits of this protocol would be feasible. MATERIALS AND METHODSIn a retrospective pilot study, the benefits of the CONVEHY protocol to manage patients with a DIR in a surgical critical care unit (CCUs) were assessed by evaluating the SOFA (Sequential Organ Failure Assessment) (He 11 ± 2.35; Ci 11 ± 3.63: p=0.54) and APACHE II (He 28.60 ± 9.40; Ci 24 ± 8.46: p=0.93) scores. RESULTSNights in hospital (He 35.2 ± 16.3 nights; Ci 9 ± 2.53: p=0.004), hospital admission after discharge from the CCUs (He 40.25 ± 21.82; Ci 13.2 ± 4.09: p=0.063), patients hospitalised >20 days (He 80%; Ci 0%: p=0.048), days requiring mechanical ventilation (He 16 ± 5.66; Ci 4 ± 1.72: p=0.004), and the predicted (55.39 ± 26.13%) versus real mortality in both groups (9.1%: p=0.004). CONCLUSIONSThe CONVEHY protocol improves the clinical responses of patients with DIR, highlighting the potential value of performing larger and confirmatory studies.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP