New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C3F8 located in the SNOLAB underground laboratory. As in previous PICO bubble ...chambers, PICO-60 C3F8 exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than one event per month. A blind analysis of an efficiency-corrected 1167-kg day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. In conclusion, these results set the most stringent direct-detection constraint to date on the weakly interacting massive particle (WIMP)-proton spin-dependent cross section at 3.4×10-41 cm2 for a 30-GeV c-2 WIMP, more than 1 order of magnitude improvement from previous PICO results.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
We reported new data from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF3I and located in the SNOLAB underground laboratory. PICO-60 is the largest ...bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 live-days, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic calorimetry, similar but not identical to that reported recently in a C3F8 bubble chamber. PICO-60 also observes a large population of unknown background events, exhibiting acoustic, spatial, and timing behaviors inconsistent with those expected from a dark matter signal. We found these behaviors allow for analysis cuts to remove all background events while retaining 48.2%of the exposure. Stringent limits on WIMPs interacting via spin-dependent proton and spin-independent processes are set, and the interpretation of the DAMA/LIBRA modulation signal as dark matter interacting with iodine nuclei is ruled out.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
New data are reported from the operation of a 2 liter C3F8 bubble chamber in the SNOLAB underground laboratory, with a total exposure of 211.5 kg days at four different energy thresholds below 10 ...keV. These data show that C3F8 provides excellent electron-recoil and alpha rejection capabilities at very low thresholds. The chamber exhibits an electron-recoil sensitivity of < 3.5 × 10–10 and an alpha rejection factor of > 98.2%. These data also include the first observation of a dependence of acoustic signal on alpha energy. Twelve single nuclear recoil event candidates were observed during the run. The candidate events exhibit timing characteristics that are not consistent with the hypothesis of a uniform time distribution, and no evidence for a dark matter signal is claimed. Lastly, these data provide the most sensitive direct detection constraints on WIMP-proton spin-dependent scattering to date, with significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon scattering.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
Within the framework of the ATLAS-MPX project, the ATLAS-MPX detectors (based on Medipix2 silicon devices) are covered with converting layers of
6LiF and polyethylene (PE) to make them sensitive to ...thermal and fast neutrons, respectively. Two ATLAS-MPX reference detectors were exposed to two calibrated neutron sources,
252Cf (2.2
MeV mean neutron energy) and
241AmBe (4.08
MeV mean neutron energy), in order to determine their fast neutron detection efficiency. Measurements were performed at low energy threshold (∼8
keV) and high energy threshold (∼230
keV). Fast neutron detection efficiency is primarily achieved via the use of a 1.3
mm thick polyethylene (PE) converter. Recoil protons from the elastic collision between neutron and hydrogen are detected from their tracks in the 300
μm thick silicon pixel detector. Calibrated neutron sources were placed at different distances from the detectors, both separately and simultaneously in order to obtain single and superposed neutron energy spectra. As expected, the neutron detection efficiency in the PE layer increases when the neutron mean energy increases due to the decrease of proton self-absorption in the PE converter itself. The variation of the cluster size as a function of the proton and alpha energy (at low energy threshold) was also studied for better understanding of the neutron response using the PE converter. The determination of the ratio of the fast neutron responses in each detector region at high energy threshold made it possible to establish a relation between the ratios and the mean neutron energy. At low energy threshold, a relation between the neutron energy spectrum and the cluster size distribution of heavy charged particles has been established.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C_{3}F_{8} located in the SNOLAB underground laboratory. As in previous PICO ...bubble chambers, PICO-60 C_{3}F_{8} exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than one event per month. A blind analysis of an efficiency-corrected 1167-kg day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. These results set the most stringent direct-detection constraint to date on the weakly interacting massive particle (WIMP)-proton spin-dependent cross section at 3.4×10^{-41} cm^{2} for a 30-GeV c^{-2} WIMP, more than 1 order of magnitude improvement from previous PICO results.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
The Project In CAnada to Search for Supersymmetric Objects (PICASSO) at SNOLAB searches for Weakly Interacting Massive Particle (WIMP) interactions with 19F. It is particularly sensitive to ...spin-dependent particle interactions. It uses a droplet technique, based on the principle of a bubble chamber, in which phase transitions in superheated liquids can be triggered by WIMP induced nuclear recoils. The detection process allows a highly efficient suppression of backgrounds from cosmic muons, γ rays and electrons. Recent results and progress are presented and future plans to scale this technique to large masses with the PICO collaboration are briefly discussed.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
The PICASSO and COUPP collaborations use superheated liquid detectors to search for cold dark matter through the direct detection of weakly interacting massive particles (WIMPs). These experiments, ...located in the underground laboratory of SNOLAB, Canada, detect phase transitions triggered by nuclear recoils in the keV range induced by interactions with WIMPs. We present details of the construction and operation of these detectors as well as the results, obtained by several years of observations. We also introduce PICO, a joint effort of the two collaborations to build a second generation ton-scale bubble chamber with 250 liters of active liquid.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
The ATLAS-MPX detectors are based on Medipix2 silicon devices designed by CERN for the detection of different types of radiation. These detectors are covered with converting layers of super(6)LiF and ...polyethylene (PE) to increase their sensitivity to thermal and fast neutrons, respectively. These devices allow the measurement of the composition and spectroscopic characteristics of the radiation field in ATLAS, particularly of neutrons. These detectors can operate in low or high preset energy threshold mode. The signature of particles interacting in a ATLAS-MPX detector at low threshold are clusters of adjacent pixels with different size and form depending on their type, energy and incidence angle. The classification of particles into different categories can be done using the geometrical parameters of these clusters. The Medipix analysis framework (MAFalda) -- based on the ROOT application -- allows the recognition of particle tracks left in ATLAS-MPX devices located at various positions in the ATLAS detector and cavern. The pattern recognition obtained from the application of MAFalda was configured to distinguish the response of neutrons from other radiation. The neutron response at low threshold is characterized by clusters of adjoining pixels (heavy tracks and heavy blobs) left by protons and heavy ions resulting from neutron interactions in the converting layers of the ATLAS-MPX devices. The neutron detection efficiency of ATLAS-MPX devices has been determined by the exposure of two detectors of reference to radionuclide sources of neutrons ( super(252)Cf and super(241)AmBe). With these results, an estimate of the neutrons fields produced at the devices locations during ATLAS operation was done.