About 95% of all fatigue damage to plate girder bridges occurs at the front of soleplates, the edge of gusset plates, and the upper end of vertical stiffeners. In the present study, the changes in ...vibration frequency and main-girder deflection that are generally used as indices to monitor the condition of a bridge were analytically investigated to determine their effectiveness, using a model that considered the influence of the types of fatigue cracks present in a real bridge. The results of a natural vibration analysis and a dynamic analysis that considered a vehicle traveling on the bridge showed that the dynamic deflection response and the vibration characteristics of the bridge changed as damage progressed. It was found to be possible to identify the conditions leading up to serious fracture of the main member and total bridge collapse. However, it was more difficult to detect incipient fatigue cracks and fracture of secondary members.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Abstract
To observe supernova relic neutrino events, 13 tons of gadolinium sulfate octahydrate (Gd2(SO4)3·8H2O), corresponding to 0.01% Gd solution, was dissolved in the Super-Kamiokande water ...Cherenkov detector in 2020. The aim is to improve the detection efficiency of neutrons from inverse β decay involving electron antineutrinos. However, Gd3+ ions can be excited by the Cherenkov light from cosmic muons, and the subsequent emission at 312 nm is a possible background (BG) source for Cherenkov signal detection. In this work, we constructed an experimental setup based on time-resolved laser-induced luminescence spectroscopy to investigate the emission characteristics of Gd3+ ions in water. The excitation laser wavelength was tuned in the range of 245–255 nm, and large resonant peaks were observed at 246.2 nm and 252.3 nm with measured emission lifetimes of around 3 ms. Good linearity was observed between Gd concentration and emission intensity for these two wavelengths, indicating that our setup is useful for remote monitoring of Gd concentration. According to the simulation results using our spectroscopic data and reference values, the Gd3+ emission BG rate from cosmic muons is expected to be 10−1 counts/μs or less, which seems small but not negligible.
The radioactive noble gas radon can be a serious background source in the underground particle physics experiments studying processes that deposit energy comparable to its decay products. Low energy ...solar neutrino measurements at Super-Kamiokande suffer from these backgrounds and therefore require precise characterization of the radon concentration in the detector’s ultra-pure water. For this purpose, we have developed a measurement system consisting of a radon extraction column, a charcoal trap, and a radon detector. In this article we discuss the design, calibration, and performance of the radon extraction column. We also describe the design of the measurement system and evaluate its performance, including its background. Using this system we measured the radon concentration in Super-Kamiokande’s water between May 2014 and October 2015. The measured radon concentration in the supply lines of the water circulation system was 1.74±0.14mBq∕m3 and in the return line was 9.06±0.58mBq∕m3. Water sampled from the center region of the detector itself had a concentration of <0.23mBq∕m3 (95% C.L.) and water sampled from the bottom region of the detector had a concentration of 2.63±0.22mBq∕m3.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We ...have used 705.9 live days of data in a fiducial volume containing 97kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was (4.2±0.2)×10−3day−1kg−1keVee−1 at 5keVee, with a signal efficiency of 20%. All the remaining events are consistent with our background evaluation, mostly of the “mis-reconstructed events” originated from 210Pb in the copper plates lining the detector's inner surface. The obtained upper limit on a spin-independent WIMP-nucleon cross section was 2.2×10−44cm2 for a WIMP mass of 60GeV/c2 at the 90% confidence level, which was the most stringent limit among results from single-phase liquid xenon detectors.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
The aim of this phase II, multicentre, randomized controlled trial was to evaluate the effectiveness of a comprehensive oral management protocol for the prevention of severe oral mucositis in ...patients with oral cancer receiving radiotherapy alone or chemoradiotherapy. In total, 124 patients with oral cancer were enrolled from five institutions. Of these, 37 patients undergoing radiotherapy were randomly divided into an intervention group (n=18) and a control group (n=19). The remaining 87 patients, who were undergoing chemoradiotherapy, were also randomized into an intervention group (n=42) and a control group (n=45). During radiotherapy, patients in the control group received only oral care, while those in the intervention group additionally received spacers to cover the entire dentition, pilocarpine hydrochloride, and topical dexamethasone ointment for oral mucositis. The primary endpoint was the incidence of severe oral mucositis. The intervention was significantly associated with a decreased incidence of severe oral mucositis in patients receiving radiotherapy alone (P=0.046), but not in those receiving chemoradiotherapy (P=0.815). These findings suggest that an oral management protocol can prevent severe oral mucositis in patients with oral cancer undergoing radiotherapy without concurrent chemotherapy.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
A search for dark matter (DM) with mass in the sub-GeV region (0.32–1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear ...scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in a total exposure of 2.38 ton-years. No significant modulation signal was observed and 90% confidence level upper limits of 1.6×10−33 cm2 at 0.5 GeV was set for the DM-nucleon cross section. This is the first experimental result of a search for DM mediated by the bremsstrahlung effect. In addition, a search for DM with mass in the multi-GeV region (4–20 GeV) was conducted with a lower energy threshold than previous analysis of XMASS. Elastic nuclear scattering was used to search down to a nuclear recoil equivalent energy of 2.3 keV, and upper limits of 2.9 ×10−42 cm2 at 8 GeV was obtained.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 ...live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the α′/α parameter related to kinetic mixing of hidden photons and the coupling constant gAe of axion-like particles in the mass range from 40 to 120 keV/c2, resulting in α′/α<6×10−26 and gAe<4×10−13. These limits are the most stringent over this mass range derived from both direct and indirect searches to date.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
We have searched for exotic neutrino-electron interactions that could be produced by a neutrino millicharge, by a neutrino magnetic moment, or by dark photons using solar neutrinos in the XMASS-I ...liquid xenon detector. We observed no significant signals in 711 days of data. We obtain an upper limit for neutrino millicharge of 5.4×10−12e at 90% confidence level assuming all three species of neutrino have common millicharge. We also set flavor-dependent limits assuming the respective neutrino flavor is the only one carrying a millicharge, 7.3×10−12e for νe, 1.1×10−11e for νμ, and 1.1×10−11e for ντ. These limits are the most stringent yet obtained from direct measurements. We also obtain an upper limit for the neutrino magnetic moment of 1.8×10−10 Bohr magnetons. In addition, we obtain upper limits for the coupling constant of dark photons in the U(1)B−L model of 1.3×10−6 if the dark photon mass is 1×10−3 MeV/c2, and 8.8×10−5 if it is 10 MeV/c2.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Abstract
The scintillation decay time constant of a ZnWO4 crystal irradiated with α-particles from 241Am was precisely investigated, and was found to depend on the incident direction of the ...α-particles on the crystal. The longest decay time constant (24.3 ± 0.6 μs) was obtained on the surface perpendicular to the b-axis of the crystal (surface B). On surfaces A and C, the decay constants were 20.0 and 21.3 ± 0.2 μs, respectively. The scintillation yield of ZnWO4 was also anisotropic and depended on the incident direction of the heavy particles. The maximum yield was achieved on surface B, suggesting a correlation between the light yield and the scintillation decay time constant of ZnWO4 crystals.
Abstract
This paper reports the development and detailed properties of about 13 metric tons of gadolinium sulfate octahydrate, $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$, which has been dissolved into ...Super-Kamiokande (SK) in the summer of 2020. We evaluate the impact of radioactive impurities in $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ on diffuse supernova neutrino background searches and solar neutrino observation and confirm the need to reduce radioactive and fluorescent impurities by about three orders of magnitude from commercially available high-purity $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$. In order to produce ultra-high-purity $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$, we have developed a method to remove impurities from gadolinium oxide, Gd2O3, consisting of acid dissolution, solvent extraction, and pH control processes, followed by a high-purity sulfation process. All of the produced ultra-high-purity $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ is assayed by inductively coupled plasma mass spectrometry and high-purity germanium detectors to evaluate its quality. Because of the long measurement time of high-purity germanium detectors, we have employed several underground laboratories for making parallel measurements including the Laboratorio Subterráneo de Canfranc in Spain, Boulby in the UK, and Kamioka in Japan. In the first half of production, the measured batch purities were found to be consistent with the specifications. However, in the latter half, the $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ contained one order of magnitude more 228Ra than the budgeted mean contamination. This was correlated with the corresponding characteristics of the raw material Gd2O3, in which an intrinsically large contamination was present. Based on their modest impact on SK physics, they were nevertheless introduced into the detector. To reduce 228Ra for the next stage of gadolinium loading to SK, a new process has been successfully established.