Abstract
We present the second release of value-added catalogues of the LAMOST Spectroscopic Survey of the Galactic Anticentre (LSS-GAC DR2). The catalogues present values of radial velocity Vr, ...atmospheric parameters – effective temperature Teff, surface gravity log g, metallicity Fe/H, α-element to iron (metal) abundance ratio α/Fe (α/M), elemental abundances C/H and N/H and absolute magnitudes MV and $M_{K_{\rm s}}$ deduced from 1.8 million spectra of 1.4 million unique stars targeted by the LSS-GAC since 2011 September until 2014 June. The catalogues also give values of interstellar reddening, distance and orbital parameters determined with a variety of techniques, as well as proper motions and multiband photometry from the far-UV to the mid-IR collected from the literature and various surveys. Accuracies of radial velocities reach 5 km s−1 for the late-type stars, and those of distance estimates range between 10 and 30 per cent, depending on the spectral signal-to-noise ratios. Precisions of Fe/H, C/H and N/H estimates reach 0.1 dex, and those of α/Fe and α/M reach 0.05 dex. The large number of stars, the contiguous sky coverage, the simple yet non-trivial target selection function and the robust estimates of stellar radial velocities and atmospheric parameters, distances and elemental abundances make the catalogues a valuable data set to study the structure and evolution of the Galaxy, especially the solar-neighbourhood and the outer disc.
As a major component of the LAMOST Galactic surveys, the LAMOST Spectroscopic Survey of the Galactic Anticentre (LSS-GAC) aims to survey a significant volume of the Galactic thin/thick discs and halo ...for a contiguous sky area of over 3400 deg2 centred on the Galactic anticentre (|b| ≤ 30°, 150 ≤ l ≤ 210°), and obtain λλ3700–9000 low-resolution (R ∼ 1800) spectra for a statistically complete sample of ∼3 M stars of all colours down to a limiting magnitude of r ∼ 17.8 mag (to 18.5 mag for limited fields). Together with Gaia, the LSS-GAC will yield a unique data set to advance our understanding of the structure and assemblage history of the Galaxy, in particular its disc(s). In addition to the main survey, the LSS-GAC will also target hundreds of thousands objects in the vicinity fields of M 31 and M 33 and survey a significant fraction (over a million) of randomly selected very bright stars (r ≤ 14 mag) in the Northern hemisphere. During the Pilot and the first year Regular Surveys of LAMOST, a total of 1042 586 750 867 spectra of a signal-to-noise ratio S/N(7450 Å) ≥ 10 S/N(4650 Å) ≥ 10 have been collected. In this paper, we present a detailed description of the target selection algorithm, survey design, observations and the first data release of value-added catalogues (including radial velocities, effective temperatures, surface gravities, metallicities, values of interstellar extinction, distances, proper motions and orbital parameters) of the LSS-GAC.
The association between infarct location and hemorrhagic transformation of acute ischemic stroke after mechanical thrombectomy is not understood. We aimed to evaluate the association between ...CTP-based ischemic core variables at admission and hemorrhagic transformation after a successful thrombectomy.
We retrospectively analyzed patients who underwent endovascular thrombectomy for acute anterior circulation large-vessel occlusion between October 2019 and June 2021. We enrolled 146 patients with visible ischemic core on pretreatment CTP who had successful reperfusion. The ischemic core infarct territories were classified into the cortical and subcortical areas and then qualitatively and quantitatively analyzed by CTP. Logistic regression and receiver operating characteristic curve analyses were performed to determine the association between ischemic core variables and hemorrhagic transformation.
Of the 146 patients analyzed, 72 (49.3%) had hemorrhagic transformation and 23 (15.8%) had symptomatic intracerebral hemorrhage. Multivariate analysis showed that subcortical infarcts were independently associated with hemorrhagic transformation (OR, 8.06; 95% CI, 2.31-28.10;
= .001) and subcortical infarct volume was independently linked to symptomatic intracerebral hemorrhage (OR, 1.05; 95% CI, 1.01-1.09;
= .039). The receiver operating characteristic curve indicated that subcortical infarcts can predict hemorrhagic transformation accurately (area under the curve = 0.755; 95% CI, 0.68-0.82;
< .001) and subcortical infarct volume can predict symptomatic intracerebral hemorrhage (area under the curve = 0.694; 95% CI, 0.61-0.77;
= .002).
Subcortical infarcts seen on CTP at admission are associated with hemorrhagic transformation in patients after successful thrombectomy, and subcortical infarct volume may influence the risk of symptomatic intracerebral hemorrhage.
Endovascular recanalization has been attempted in patients with symptomatic chronic ICA occlusion, however, the heterogeneity of recanalization outcomes and the perioperative complications present ...challenges for the clinical application. Our aim was to evaluate the safety and efficacy of endovascular recanalization for symptomatic chronic ICA occlusion and identify potential predictors for successful recanalization.
This study included 47 consecutive patients with symptomatic chronic ICA occlusion who underwent endovascular recanalization at our institution. Patients' clinical information, radiologic characteristics, procedural results, and outcomes were recorded. Factors related to technical success were analyzed by univariate and multivariate analyses.
The technical success rate was 74.5% (35/47); 12.8% of patients (6/47) experienced intraoperative complications, but none had permanent neurologic deficits. Three months after recanalization, 21 of the 29 recanalized patients (72.4%) and 3 of the 10 failed patients (30.0%) demonstrated improved mRS scores. Restenosis or re-occlusion occurred in 12.9% of patients (4/31) with successful recanalization. Multivariate analysis showed that tapered or blunt stump (
= .016), distal ICA occlusion segment (below the cavernous segment versus at or above the ophthalmic segment,
= .003; at the cavernous or clinoid segment versus at or above the ophthalmic segment,
= .027), and radiologic occlusion to recanalization of ≤3 months (
= .044) were significantly associated with successful recanalization. Patients were assigned points according to the coefficients of the prediction model, and the technical success rates were 0%, 46.2%, 90.5%, and 100% in patients with 1, 2, 3, and 4 points, respectively.
Endovascular recanalization is a safe and effective treatment for symptomatic chronic ICA occlusion in selected patients. A residual stump, low levels of the distal ICA occlusion segment, and a short radiologic occlusion time were identified as positive predictors of technical success.
To describe the experience of endovascular treatment (EVT) of acute ischaemic stroke caused by isolated internal carotid artery (ICA) occlusion, with emphasis on treatment strategies, outcomes, and ...prognostic factors.
A retrospective examination was performed of 66 consecutive patients with acute moderate-to-severe stroke who underwent EVT for isolated ICA occlusion from July 2016 to June 2021. The modified thrombolysis in cerebral ischaemia (mTICI) score was used to evaluate reperfusion outcomes. A multivariate analysis was performed to identify risk factors associated with poor 90-day outcome (modified Rankin Scale mRS 3–6).
The National Institutes of Health Stroke Scale (NIHSS) median score of the 66 patients at admission was 15. Twelve patients (18.2%) showed thrombus migration to the M1 segment or proximal M2 during EVT and underwent additional intracranial thrombectomy. Successful reperfusion (mTICI 2b–3) was achieved in 60 patients (90.9%) and complete reperfusion (mTICI 3) in 42 (63.6%). A poor functional outcome was seen in 27 patients (40.9%). The rate of 90-day mortality was 9.1% (6/66). Higher NIHSS scores and a lower Alberta Stroke Program Early CT Score (ASPECTS) were independently associated with poor outcomes. Complete reperfusion was the only treatment factor with a significant predictive value (adjusted odds ratio OR 0.03; 95% CI = 0.01 to 0.25; p=0.001).
Endovascular therapy is safe and effective in patients with acute ischaemic stroke due to isolated ICA occlusion. Prevention of thrombus migration and complete reperfusion should be the aim of EVT.
•Thrombus migration is common during thrombectomy for isolated ICA occlusion.•Complete reperfusion should be the aim of thrombectomy for isolated ICA occlusion.•Addition of data helps guide treatment for isolated ICA occlusion.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Many patients who require allogeneic hematopoietic stem cell transplantation (allo-HSCT) lack a human leukocyte antigen (HLA)-matched donor. Here, we report a protocol for haploidentical allo-HSCT ...that combines granulocyte-colony stimulating factor primed bone marrow (G-BM) and peripheral blood stem cells (PBSC) without in vitro T-cell depletion (TCD). In this study, 171 patients, including 86 in high-risk group, underwent transplantation from haploidentical family donors. All patients achieved sustained, full donor chimerism. One hundred and eleven patients were alive in remission at a median of 682 (253-1502) days. The cumulative incidence of grade III-IV acute graft-versus-host disease (GVHD) was 23% and that of extensive chronic GVHD, 47%; these were not influenced by HLA disparity. Patients younger than 15 years had less grade III-IV acute GVHD than older patients (P=0.044). The 2-year probability of relapse was 12% for standard-risk disease and 39% for high-risk disease. The 2-year probability of leukemia-free survival (LFS) was 68% for standard-risk patients and 42% for high-risk patients (P=0.0009). Grade III-IV acute GVHD was associated with better LFS (P=0.0017). The results require confirmation and show that G-BM combined with PBSC from haploidentical family donors, without in vitro TCD, may be used as a good source of stem cells for allo-HSCT.
Full text
Available for:
DOBA, EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, IZUM, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UILJ, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
The impact of impurity ions on a pedestal has been investigated in the HL-2A Tokamak, at the Southwestern Institute of Physics, Chengdu, China. Experimental results have clearly shown that during the ...H-mode phase, an electromagnetic turbulence was excited in the edge plasma region, where the impurity ions exhibited a peaked profile. It has been found that double impurity critical gradients are responsible for triggering the turbulence. Strong stiffness of the impurity profile has been observed during cyclic transitions between the I-phase and H-mode regime. The results suggest that the underlying physics of the self-regulated edge impurity profile offers the possibility for an active control of the pedestal dynamics via pedestal turbulence.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
Accurate determination of stellar atmospheric parameters and elemental abundances is crucial for Galactic archaeology via large-scale spectroscopic surveys. In this paper, we estimate stellar ...atmospheric parameters -- effective temperature T sub( eff), surface gravity log g and metallicity Fe/H, absolute magnitudes M sub( V) and M sub( Ks), ...-element to metal (and iron) abundance ratio .../M (and .../Fe), as well as carbon and nitrogen abundances C/H and N/H from the Large Sky Area Multi-Object Fibre Spectroscopic Telescope (LAMOST) spectra with a multivariate regression method based on kernel-based principal component analysis, using stars in common with other surveys (Hipparcos, Kepler, Apache Point Observatory Galactic Evolution Experiment) as training data sets. Both internal and external examinations indicate that given a spectral signal-to-noise ratio (SNR) better than 50, our method is capable of delivering stellar parameters with a precision of ~100 K for T sub( eff), ~0.1 dex for log g, 0.3-0.4 mag for M sub( V) and M sub( Ks), 0.1 dex for Fe/H, C/H and N/H, and better than 0.05 dex for .../M (.../Fe). The results are satisfactory even for a spectral SNR of 20. The work presents first determinations of C/H and N/H abundances from a vast data set of LAMOST, and, to our knowledge, the first reported implementation of absolute magnitude estimation directly based on a vast data set of observed spectra. The derived stellar parameters for millions of stars from the LAMOST surveys will be publicly available in the form of value-added catalogues. (ProQuest: ... denotes formulae/symbols omitted.)
Particle trapping and binding in optical potential wells provide a versatile platform for various biomedical applications. However, implementation systems to study multi-particle contact interactions ...in an optical lattice remain rare. By configuring an optofluidic lattice, we demonstrate the precise control of particle interactions and functions such as controlling aggregation and multi-hopping. The mean residence time of a single particle is found considerably reduced from 7 s, as predicted by Kramer's theory, to 0.6 s, owing to the mechanical interactions among aggregated particles. The optofluidic lattice also enables single-bacteria-level screening of biological binding agents such as antibodies through particle-enabled bacteria hopping. The binding efficiency of antibodies could be determined directly, selectively, quantitatively and efficiently. This work enriches the fundamental mechanisms of particle kinetics and offers new possibilities for probing and utilising unprecedented biomolecule interactions at single-bacteria level.
We introduce the Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) stellar parameter pipeline at Peking University – lsp3, developed and implemented for the determinations of radial ...velocity V
r and stellar atmospheric parameters (effective temperature T
eff, surface gravity log g, metallicity Fe/H) for the LAMOST Spectroscopic Survey of the Galactic Anticentre (LSS-GAC). We describe the algorithms of lsp3 and examine the accuracy of parameters yielded by it. The precision and accuracy of parameters yielded are investigated by comparing results of multi-epoch observations and of candidate members of open and globular clusters, with photometric calibration, as well as with independent determinations available from a number of external data bases, including the PASTEL archive, the APOGEE, SDSS and RAVE surveys, as well as those released in the LAMOST DR1. The uncertainties of lsp3 parameters are characterized and quantified as a function of the spectral signal-to-noise ratio (SNR) and stellar atmospheric parameters. We conclude that the current implementation of lsp3 has achieved an accuracy of 5.0 km s−1, 150 K, 0.25 dex, 0.15 dex for the radial velocity, effective temperature, surface gravity and metallicity, respectively, for LSS-GAC spectra of FGK stars of SNRs per pixel higher than 10. The lsp3 has been applied to over a million LSS-GAC spectra collected hitherto. Stellar parameters yielded by the lsp3 will be released to the general public following the data policy of LAMOST, together with estimates of the interstellar extinction E(B − V) and stellar distances, deduced by combining spectroscopic and multiband photometric measurements using a variety of techniques.