Summary Background Renal sympathetic hyperactivity is associated with hypertension and its progression, chronic kidney disease, and heart failure. We did a proof-of-principle trial of therapeutic ...renal sympathetic denervation in patients with resistant hypertension (ie, systolic blood pressure ≥160 mm Hg on three or more antihypertensive medications, including a diuretic) to assess safety and blood-pressure reduction effectiveness. Methods We enrolled 50 patients at five Australian and European centres; 5 patients were excluded for anatomical reasons (mainly on the basis of dual renal artery systems). Patients received percutaneous radiofrequency catheter-based treatment between June, 2007, and November, 2008, with subsequent follow-up to 1 year. We assessed the effectiveness of renal sympathetic denervation with renal noradrenaline spillover in a subgroup of patients. Primary endpoints were office blood pressure and safety data before and at 1, 3, 6, 9, and 12 months after procedure. Renal angiography was done before, immediately after, and 14–30 days after procedure, and magnetic resonance angiogram 6 months after procedure. We assessed blood-pressure lowering effectiveness by repeated measures ANOVA. This study is registered in Australia and Europe with ClinicalTrials.gov , numbers NCT 00483808 and NCT 00664638. Findings In treated patients, baseline mean office blood pressure was 177/101 mm Hg (SD 20/15), (mean 4·7 antihypertensive medications); estimated glomerular filtration rate was 81 mL/min/1·73m2 (SD 23); and mean reduction in renal noradrenaline spillover was 47% (95% CI 28–65%). Office blood pressures after procedure were reduced by −14/−10, −21/−10, −22/−11, −24/−11, and −27/−17 mm Hg at 1, 3, 6, 9, and 12 months, respectively. In the five non-treated patients, mean rise in office blood pressure was +3/−2, +2/+3, +14/+9, and +26/+17 mm Hg at 1, 3, 6, and 9 months, respectively. One intraprocedural renal artery dissection occurred before radiofrequency energy delivery, without further sequelae. There were no other renovascular complications. Interpretation Catheter-based renal denervation causes substantial and sustained blood-pressure reduction, without serious adverse events, in patients with resistant hypertension. Prospective randomised clinical trials are needed to investigate the usefulness of this procedure in the management of this condition. Funding Ardian Inc.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
The transcatheter mitral valve interventions (TRAMI) registry was established in order to assess safety and efficacy of catheter-based mitral valve interventional techniques in Germany, and ...prospectively enrolled 828 MitraClip patients (median age 76 years, median log. EuroSCORE I 20.0%) between August 2010 and July 2013. We present the 1-year outcome in this MitraClip cohort-which is the largest published to date.
Seven forty-nine patients (90.5%) were available for 1-year follow-up and included in the following analyses. Mortality, major adverse cardiovascular event rates, and New York Heart Association (NYHA) classes were recorded. Predictors of 1-year mortality were identified by multivariate analysis using a Cox regression model with stepwise forward selection. The 1-year mortality was 20.3%. At 1 year, 63.3% of TRAMI patients pertained to NYHA functional classes I or II (compared with 11.0% at baseline), and self-rated health status (on EuroQuol visual analogue scale) also improved significantly by 10 points. Importantly, a significant proportion of patients regained the complete independence in self-care after MitraClip implantation (independence in 74.0 vs. 58.6% at baseline, P = 0.005). Predictors of 1-year mortality were NYHA class IV (hazard ratio, HR 1.62, P = 0.02), anaemia (HR 2.44, P = 0.02), previous aortic valve intervention (HR 2.12, P = 0.002), serum creatinine ≥1.5 mg/dL (HR 1.77, P = 0.002), peripheral artery disease (HR 2.12, P = 0.0003), left ventricular ejection fraction <30% (HR 1.58, P = 0.01), severe tricuspid regurgitation (HR 1.84, P = 0.003), and procedural failure (defined as operator-reported failure, conversion to surgery, failure of clip placement, or residual post-procedural severe mitral regurgitation) (HR 4.36, P < 0.0001).
Treatment of significant MR with MitraClip resulted in significant clinical improvements in a high proportion of TRAMI patients after 12 months. In the TRAMI cohort, the failure of procedural success exhibited the highest hazard ratio concerning the prediction of 1-year mortality.
Abstract Background In the PROTECT AF (Watchman Left Atrial Appendage Closure Technology for Embolic Protection in Patients With Atrial Fibrillation) trial that evaluated patients with nonvalvular ...atrial fibrillation (NVAF), left atrial appendage (LAA) occlusion was noninferior to warfarin for stroke prevention, but a periprocedural safety hazard was identified. Objectives The goal of this study was to assess the safety and efficacy of LAA occlusion for stroke prevention in patients with NVAF compared with long-term warfarin therapy. Methods This randomized trial further assessed the efficacy and safety of the Watchman device. Patients with NVAF who had a CHADS2 (congestive heart failure, hypertension, age >75 years, diabetes mellitus, and previous stroke/transient ischemic attack) score ≥2 or 1 and another risk factor were eligible. Patients were randomly assigned (in a 2:1 ratio) to undergo LAA occlusion and subsequent discontinuation of warfarin (intervention group, n = 269) or receive chronic warfarin therapy (control group, n = 138). Two efficacy and 1 safety coprimary endpoints were assessed. Results At 18 months, the rate of the first coprimary efficacy endpoint (composite of stroke, systemic embolism SE, and cardiovascular/unexplained death) was 0.064 in the device group versus 0.063 in the control group (rate ratio 1.07 95% credible interval (CrI): 0.57 to 1.89) and did not achieve the prespecified criteria noninferiority (upper boundary of 95% CrI ≥1.75). The rate for the second coprimary efficacy endpoint (stroke or SE >7 days’ postrandomization) was 0.0253 versus 0.0200 (risk difference 0.0053 95% CrI: –0.0190 to 0.0273), achieving noninferiority. Early safety events occurred in 2.2% of the Watchman arm, significantly lower than in PROTECT AF, satisfying the pre-specified safety performance goal. Using a broader, more inclusive definition of adverse effects, these still were lower in PREVAIL (Watchman LAA Closure Device in Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy) trial than in PROTECT AF (4.2% vs. 8.7%; p = 0.004). Pericardial effusions requiring surgical repair decreased from 1.6% to 0.4% (p = 0.027), and those requiring pericardiocentesis decreased from 2.9% to 1.5% (p = 0.36), although the number of events was small. Conclusions In this trial, LAA occlusion was noninferior to warfarin for ischemic stroke prevention or SE >7 days’ post-procedure. Although noninferiority was not achieved for overall efficacy, event rates were low and numerically comparable in both arms. Procedural safety has significantly improved. This trial provides additional data that LAA occlusion is a reasonable alternative to warfarin therapy for stroke prevention in patients with NVAF who do not have an absolute contraindication to short-term warfarin therapy.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
The right ventricular (RV)-pulmonary arterial (PA) coupling ratio relates the efficiency with which RV stroke work is transferred into the PA. Lower ratios indicate an inadequate RV contractile ...response to increased afterload.
This study sought to evaluate the prognostic significance of RV-PA coupling in patients with tricuspid regurgitation (TR) who were undergoing transcatheter tricuspid valve repair or replacement (TTVR).
The study investigators calculated RV-PA coupling ratios for patients enrolled in the global TriValve registry by dividing the tricuspid annular plane systolic excursion (TAPSE) by the PA systolic pressure (PASP) from transthoracic echocardiograms performed before the procedure and 30 days after the procedure. The primary endpoint was all-cause mortality at 1-year follow-up.
Among 444 patients analyzed, their mean age was 76.9 ± 9.1 years, and 53.8% of the patients were female. The median TAPSE/PASP ratio was 0.406 mm/mm Hg (interquartile range: 0.308-0.567 mm/mm Hg). Sixty-three patients died within 1 year of TTVR, 21 with a TAPSE/PASP ratio >0.406 and 42 with a TAPSE/PASP ratio ≤0.406. In multivariable Cox regression analysis, a TAPSE/PASP ratio >0.406 vs ≤0.406 was associated with a decreased risk of all-cause mortality (HR: 0.57; 95% CI: 0.35-0.93; P = 0.023). In 234 (52.7%) patients with echocardiograms 30 days after TTVR, a decline in RV-PA coupling was independently associated with reduced odds of all-cause mortality (odds ratio OR: 0.42; 95% CI: 0.19-0.93; P = 0.032). The magnitude of TR reduction after TTVR (≥1+ vs <1+; OR: 2.53; 95% CI: 1.06-6.03; P = 0.037) was independently associated with a reduction in post-TTVR RV-PA coupling.
RV-PA coupling is a powerful, independent predictor of all-cause mortality in patients with TR undergoing TTVR. These data suggest that the TAPSE/PASP ratio can inform patient selection and prognostication following TTVR.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Objectives The purpose of this article is to report early and mid-term outcomes of the ACCESS-EU study (ACCESS-Europe A Two-Phase Observational Study of the MitraClip System in Europe), a European ...prospective, multicenter, nonrandomized post-approval study of MitraClip therapy (Abbott Vascular, Inc., Santa Clara, California). Background MitraClip has been increasingly performed in Europe after approval; the ACCESS-EU registry provides a snapshot of the real-world clinical demographic data and outcomes. Methods A total of 567 patients with significant mitral valve regurgitation (MR) underwent MitraClip therapy at 14 European sites. Mean logistic European System for Cardiac Operative Risk Evaluation at baseline was 23.0 ± 18.3; 84.9% patients were in New York Heart Association functional class III or IV, and 52.7% of patients had an ejection fraction ≤40%. Results The MitraClip implant rate was 99.6%. A total of 19 patients (3.4%) died within 30 days after the MitraClip procedure. The Kaplan-Meier survival at 1 year was 81.8%. Intensive care unit and hospital length of stay was 2.5 ± 6.5 days and 7.7 ± 8.2 days, respectively. Single leaflet device attachment was reported in 27 patients (4.8%). There were no MitraClip device embolizations. Thirty-six subjects (6.3%) required mitral valve surgery within 12 months after the MitraClip implant procedure. There was improvement in the severity of MR at 12 months, compared with baseline (p < 0.0001), with 78.9% of patients free from MR, severity of >2+ at 12 months. At 12 months, 71.4% of patients had New York Heart Association functional class II or class I. Six-min-walk-test improved 59.5 ± 112.4 m, and Minnesota-living-with-heart-failure score improved 13.5 ± 20.5 points. Conclusions In the real-world, post-approval experience in Europe, patients undergoing the MitraClip therapy are high-risk, elderly patients, mainly affected by functional MR. In this patient population, the MitraClip procedure is effective with low rates of hospital mortality and adverse events.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
...it is not surprising that pulmonary vein stenoses have been described after pulmonary vein isolation with radiofrequency energy (2). Taking into account the large number of patients with resistant ...hypertension worldwide and, hence, expected number of patients referred for and treated with RDN, it is very important to continue close follow-up of patients treated with RDN. ...participation in registries with reliable imaging follow-up allowing consistent reporting of this complication should be encouraged.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Transcatheter aortic valve implantation (TAVI) is already an accepted option to treat elderly patients with severe symptomatic aortic stenosis who are inoperable or at high surgical risk. However, ...short- and long-term mortality after TAVI remains an important issue, raising the need to further improve the technology of TAVI as well as to identify patients who will not benefit from TAVI. A total of 1,391 patients treated with TAVI at 27 hospitals were included in the German Transcatheter Aortic Valve Interventions – Registry. One-year follow-up data were available for 1,318 patients (94.8%), with a mean follow-up period of 12.9 ± 4.5 months. One-year mortality was 19.9%. Survivors and nonsurvivors showed multiple differences in patient characteristics, indications for interventions, preintervention and interventional characteristics, and postintervention events. A higher logistic European System for Cardiac Operative Risk Evaluation score was associated with higher 1-year mortality (p <0.0001). Cox proportional-hazards analysis revealed the following independent predictors of mortality: among preintervention findings: previous mitral insufficiency ≥II° (p = 0.0005), low-gradient aortic stenosis (p = 0.0008), previous decompensation (p = 0.0061), previous myocardial infarction (p = 0.0138), renal failure (p = 0.0180), previous New York Heart Association class IV (p = 0.0254), and female gender (p = 0.0346); among procedural factors: intraprocedural conversion to surgery (p = 0.0009), peri-intervention stroke (p = 0.0003), and residual aortic insufficiency ≥II° (p = 0.0022); and among postprocedural events: postintervention myocardial infarction (p = 0.0009) and postintervention pulmonary embolism (p = 0.0025). In conclusion, 1-year mortality after TAVI was 19.9% in this series. Patient characteristics and procedural as well as postintervention factors associated with mortality were identified, which may allow better patient selection and better care for these critically ill patients.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
Summary Background In patients with non-valvular atrial fibrillation, embolic stroke is thought to be associated with left atrial appendage (LAA) thrombi. We assessed the efficacy and safety of ...percutaneous closure of the LAA for prevention of stroke compared with warfarin treatment in patients with atrial fibrillation. Methods Adult patients with non-valvular atrial fibrillation were eligible for inclusion in this multicentre, randomised non-inferiority trial if they had at least one of the following: previous stroke or transient ischaemic attack, congestive heart failure, diabetes, hypertension, or were 75 years or older. 707 eligible patients were randomly assigned in a 2:1 ratio by computer-generated randomisation sequence to percutaneous closure of the LAA and subsequent discontinuation of warfarin (intervention; n=463) or to warfarin treatment with a target international normalised ratio between 2·0 and 3·0 (control; n=244). Efficacy was assessed by a primary composite endpoint of stroke, cardiovascular death, and systemic embolism. We selected a one-sided probability criterion of non-inferiority for the intervention of at least 97·5%, by use of a two-fold non-inferiority margin. Serious adverse events that constituted the primary endpoint for safety included major bleeding, pericardial effusion, and device embolisation. Analysis was by intention to treat. This study is registered with Clinicaltrials.gov , number NCT00129545. Findings At 1065 patient-years of follow-up, the primary efficacy event rate was 3·0 per 100 patient-years (95% credible interval CrI 1·9–4·5) in the intervention group and 4·9 per 100 patient-years (2·8–7·1) in the control group (rate ratio RR 0·62, 95% CrI 0·35–1·25). The probability of non-inferiority of the intervention was more than 99·9%. Primary safety events were more frequent in the intervention group than in the control group (7·4 per 100 patient-years, 95% CrI 5·5–9·7, vs 4·4 per 100 patient-years, 95% CrI 2·5–6·7; RR 1·69, 1·01–3·19). Interpretation The efficacy of percutaneous closure of the LAA with this device was non-inferior to that of warfarin therapy. Although there was a higher rate of adverse safety events in the intervention group than in the control group, events in the intervention group were mainly a result of periprocedural complications. Closure of the LAA might provide an alternative strategy to chronic warfarin therapy for stroke prophylaxis in patients with non-valvular atrial fibrillation. Funding Atritech.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
Left atrial appendage (LAA) occlusion with WATCHMAN has emerged as viable alternative to vitamin K antagonists in randomized controlled trials.
EWOLUTION was designed to provide data in routine ...practice from a prospective multicenter registry.
A total of 1025 patients scheduled for a WATCHMAN implant were prospectively and sequentially enrolled at 47 centers. Indication for LAA closure was based on European Society of Cardiology guidelines. Follow-up and transesophageal echocardiography (TEE) were performed per local practice.
The baseline CHA
DS
-VASc score was 4.5 ± 1.6; the mean age was 73.4 ± 9 years; previous transient ischemic attack/ischemic stroke was present in 312 (30.5%), 155 (15.1%) had previous hemorrhagic stroke, and 320 (31.3%) had a history of major bleeding; and 750 (73%) were deemed unsuitable for oral anticoagulation therapy. WATCHMAN implant succeeded in 1005 (98.5%) of patients, without leaks >5 mm in 1002 (99.7%) with at least 1 TEE follow-up in 875 patients (87%). Antiplatelet therapy was used in 784 (83%), while vitamin K antagonists were used in only 75 (8%). At 1 year, mortality was 98 (9.8%), reflecting the advanced age and comorbidities in this population. Device thrombus was observed in 28 patients at routine TEE (3.7%) and was not correlated with the drug regimen (P = .14). Ischemic stroke rate was 1.1% (relative risk 84% vs estimated historical data); the major bleeding rate was 2.6% and was predominantly (2.3%) nonprocedure/device related.
LAA closure with the WATCHMAN device has a high implant and sealing success. This method of stroke risk reduction appears to be safe and effective with an ischemic stroke rate as low as 1.1%, even though 73% of patients had a contraindication to and were not using oral anticoagulation.