In the frame of research and development for electromagnetic calorimetry at future e/sup +/e/sup -/ linear colliders, different techniques have been studied to implement longitudinal segmentation in ...Shashlik calorimeters. Two prototypes with 5/spl times/5 cm/sup 2/ lead/scintillator towers and readout by means of wavelength-shifting fibers have been built. The longitudinal segmentation of the shower is achieved by modifying the front part of the detector. In the first prototype, vacuum photodiodes have been inserted laterally for the first eight X/sub 0/, while in the second prototype a slow scintillator has been used in the first five X/sub 0/. Both of the prototypes have been exposed to beam at CERN. The performance in term of energy resolution, spatial resolution, and e//spl pi/ separation are described.
Two techniques for longitudinal segmentation of shashlik calorimeters are proposed. Results concerning energy resolution and e/π separation are reported.
Full text
Available for:
IJS, IMTLJ, KILJ, KISLJ, NUK, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
To sustain and extend its discovery potential, the Large Hadron Collider (LHC) will undergo a major upgrade in the coming years, referred to as High Luminosity LHC (HLLHC), aimed to increase its ...instantaneous luminosity, 5 times larger than the designed limit, and, consequently leading to high levels of radiation, with the goal to collect 10 times larger the original designed integrated luminosity. The drift tube chambers (DT) of CMS muon detector system is built to proficiently measure and trigger on muons in the harsh radiation environment expected during the HL-LHC era. Ageing studies are performed at the CERNs gamma ray irradiation facility (GIF++) by measuring the muon hit efficiency of these detectors at various LHC operation conditions. One such irradiation campaign was started in October 2017, when a spare MB2 chamber moved inside the bunker and irradiated at lower acceleration factors. Two out of twelve layers of the DT chamber were operated while being irradiated with the radioactive source and then their muon hit efficiency was calculated in coincidence with other ten layers which were kept on the standby. The chamber absorbed an integrated dose equivalent to two times the expected integrated luminosity of the HL-LHC. Investigation on the outgassing of cell materials and of the gas components used at the GIF++ are underway and strategies to mitigate the aging effects are also being developed. The effect of radiation on the performance of DT chamber and its impact on the overall muon reconstruction efficiency expected during the HL-LHC are presented.
An electromagnetic shashlik calorimeter with longitudinal segmentation Benvenuti, A.C; Britvich, I; Camporesi, T ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
08/1999, Volume:
432, Issue:
2-3
Journal Article
Peer reviewed
Open access
A novel technique for longitudinal segmentation of shashlik calorimeters has been tested in the CERN West Area beam facility. A 25 tower very fine samplings e.m. calorimeter has been built with ...vacuum photodiodes inserted in the first 8 radiation lengths to sample the initial development of the shower. Results concerning energy resolution, impact point reconstruction and e/π separation are reported.
Full text
Available for:
IJS, IMTLJ, KILJ, KISLJ, NUK, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK
The reaction of hydrogen evolution from the acids: hydrochloric, hydrogen sulfate ion, monochloroacetic and lactic have been studied by steady-state voltammetry at platinum microdisc electrodes. From ...the experimental voltammetric parameters, such as half-wave potential, (
E
1
4
– E
3
4
) values and steady-state limiting current, it has been ascertained that the second order CE mechanism, involved in the discharge of protons arising from the weak acids investigated, is characterized by a chemical reaction which is fast over the whole concentration range explored. Theoretical calibration plots have been examined in the concentration range 1 × 10
−6–1 × 10
−1
M and the zone over which linearity exists has been verified both from a theoretical and experimental point of view.
Full text
Available for:
IJS, IMTLJ, KILJ, KISLJ, NUK, SBCE, SBJE, UL, UM, UPCLJ, UPUK
9.
Shashlik calorimeter prototypes for a linear collider Benvenuti, A.C.; Britvich, I.; Camporesi, T. ...
1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019),
1999, Volume:
1
Conference Proceeding
Two techniques for longitudinal segmentation of shashlik calorimeters are proposed. Results concerning energy resolution, impact point reconstruction and e//spl pi/ separation are reported.