Background:
The incidence of surgical site infection (SSI) across surgical procedures, specialties, and conditions is reported to vary from 0.1% to 50%. Operative duration is often cited as an ...independent and potentially modifiable risk factor for SSI. The objective of this systematic review was to provide an in-depth understanding of the relation between operating time and SSI.
Patients and Methods:
This review included 81 prospective and retrospective studies. Along with study design, likelihood of SSI, mean operative times, time thresholds, effect measures, confidence intervals, and p values were extracted. Three meta-analyses were conducted, whereby odds ratios were pooled by hourly operative time thresholds, increments of increasing operative time, and surgical specialty.
Results:
Pooled analyses demonstrated that the association between extended operative time and SSI typically remained statistically significant, with close to twice the likelihood of SSI observed across various time thresholds. The likelihood of SSI increased with increasing time increments; for example, a 13%, 17%, and 37% increased likelihood for every 15 min, 30 min, and 60 min of surgery, respectively. On average, across various procedures, the mean operative time was approximately 30 min longer in patients with SSIs compared with those patients without.
Conclusions:
Prolonged operative time can increase the risk of SSI. Given the importance of SSIs on patient outcomes and health care economics, hospitals should focus efforts to reduce operative time.
Background A patient-level meta-analysis of 5 randomized trials including 4,896 patients found that the XIENCE(TM) cobalt chromium everolimus drug-eluting stent (DES) significantly improved ...cardiovascular (CV) outcomes compared with bare metal stents (BMS) (Valgimigli et al., 2014).
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Aim: Progel Pleural Air Leak Sealant (Progel) is currently the only sealant approved by the FDA for the treatment of air leaks during lung surgery. This study was performed to determine whether ...Progel use improves hospital length of stay (LOS) and hospitalization costs compared with other synthetic/fibrin sealants in patients undergoing lung surgery.
Methods: The US Premier hospital database was used to identify lung surgery discharges from January 1, 2010 to June 30, 2015. Eligible discharges were categorized as "Progel Sealant" or "other sealants" using hospital billing data. Propensity score matching (PSM) was performed to control for hospital and patient differences between study groups. Primary outcomes were hospital LOS and all-cause hospitalization costs. Clinical outcomes, hospital re-admissions, and sealant product use were also described.
Results: After PSM, a total of 2,670 discharges were included in each study group; baseline characteristics were balanced between groups. The hospital LOS (mean days ± standard deviation, median) was significantly shorter for the Progel group (9.9 ± 9.6, 7.0) compared with the other sealants group (11.3 ± 12.8, 8.0; p < .001). Patients receiving Progel incurred significantly lower all-cause hospitalization costs ($31,954 ± $29,696, $23,904) compared with patients receiving other sealants ($36,147 ± $42,888, $24,702; p < .001).
Limitations: It is not possible to say that sealant type alone was responsible for the findings of this study, and analysis was restricted to the data available in the Premier database.
Conclusions: Among hospital discharges for lung surgery, Progel use was associated with significantly shorter hospital LOS and lower hospitalization costs compared with other synthetic/fibrin sealants, without compromising clinical outcomes.
Objectives: Harmonic devices have become a world-wide standard for dissection and hemostasis in thyroidectomy. Numerous systematic reviews have reported superior operating times, blood loss, ...post-operative pain, length of stay, and overall safety outcomes. What has not been extensively evaluated in a robust manner is their economic impact. The purpose of this study is to evaluate the hospital costs associated with open thyroidectomy using Harmonic devices compared with conventional techniques for hemostasis. Methods: A systematic review of Medline, Scopus, and CENTRAL was performed from January 1, 2000 to May 23, 2014 without language restrictions for randomized clinical trials comparing Harmonic surgical devices to conventional methods in thyroidectomy. The main outcome measure was total reported costs. Costs were pooled using the ratio of means and a random effects model. Sensitivity analyses assessed whether differences in patient and trial characteristics, healthcare setting, or choice of statistical model affected outcomes. Results: Seven studies met the inclusion criteria. A total of 476 participants had procedures performed with Harmonic devices and 478 with conventional monopolar electrosurgery and clamp, cut and tie techniques. Compared with conventional techniques, Harmonic devices reduced total reported costs by 10% (p = 0.007), resulting in a $229 US dollars (USD) absolute reduction from mean baseline costs. Results remained relatively robust to additional sensitivity analyses. Conclusions: This systematic review and meta-analysis demonstrates that the Harmonic family of surgical devices is associated with a reduction in total reported costs in thyroidectomy compared with conventional techniques. A large portion of the overall savings derives from a reduction in operative costs.
Mastectomy and breast-conserving surgery (BCS) are important treatment options for breast cancer patients. A previous meta-analysis demonstrated that the risk of certain complications can be reduced ...with the Harmonic technology compared with conventional methods in mastectomy. However, the meta-analysis did not include studies of BCS patients and focused on a subset of surgical complications. The objective of this study was to compare Harmonic technology and conventional techniques for a range of clinical outcomes and complications in both mastectomy and BCS patients, including axillary lymph node dissection.
A comprehensive literature search was performed for randomized controlled trials comparing Harmonic technology and conventional methods in breast cancer surgery. Outcome measures included blood loss, drainage volume, total complications, seroma, necrosis, wound infections, ecchymosis, hematoma, hospital length of stay, and operating time. Risk of bias was analyzed for all studies. Meta-analysis was performed using random-effects models for mean differences of continuous variables and a fixed-effects model for risk ratios of dichotomous variables.
Twelve studies met the inclusion criteria. Across surgery types, compared to conventional techniques, Harmonic technology reduced total complications by 52% (P=0.002), seroma by 46% (P<0.0001), necrosis by 49% (P=0.04), postoperative chest wall drainage by 46% (P=0.0005), blood loss by 38% (P=0.0005), and length of stay by 22% (P=0.007). Although benefits generally appeared greatest in mastectomy patients with lymph node dissection, Harmonic technology showed significant reductions in complications in the BCS study subgroup.
In this meta-analysis of both mastectomy and BCS procedures, the use of Harmonic technology reduced the risk of most complications by about half across breast cancer surgery patients. These benefits may be due to superior hemostatic capabilities of Harmonic technology and better dissection, particularly lymph node dissection. Reduction in complications and other resource outcomes may engender lower downstream health care costs.
In pancreatic cancer, the incidence and mortality curves coincide. One major reason for this high mortality rate in pancreatic ductal adenocarcinoma (PDAC) patients is the dearth of effective ...diagnostic, prognostic, and disease-monitoring biomarkers. Unfortunately, existing tumor markers, as well as current imaging modalities, are not sufficiently sensitive and/or specific for early-stage diagnosis. There is, therefore, an urgent need for improved serum markers of the disease. Herein, we performed Orbitrap® mass spectrometry proteomic analysis of four PDAC tissues and their adjacent benign tissues and identified a total of 2190 nonredundant proteins. Sixteen promising candidates were selected for further scrutiny using a systematic scoring algorithm. Our preliminary serum verification of the top four candidates (DSP, LAMC2, GP73, and DSG2) in 20 patients diagnosed with pancreatic cancer and 20 with benign pancreatic cysts, showed a significant (p < 0.05) elevation of LAMC2 in pancreatic cancer serum. Extensive validation of LAMC2 in healthy, benign, and PDAC sera from geographically diverse cohorts (n = 425) (Japan, Europe, and USA) demonstrated a significant increase in levels in early-stage PDAC compared with benign diseases. The sensitivity of LAMC2 was comparable to CA19.9 in all data sets, with an AUC value greater than 0.85 in discriminating healthy patients from early-stage PDAC patients. LAMC2 exhibited diagnostic complementarity with CA19.9 by showing significant (p < 0.001 in two out of three cohorts) elevation in PDAC patients with clinically low CA19.9 levels.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
The identification of new serum biomarkers with high sensitivity and specificity is an important priority in pancreatic cancer research. Through an extensive proteomics analysis of pancreatic cancer ...cell lines and pancreatic juice, we previously generated a list of candidate pancreatic cancer biomarkers. The present study details further validation of four of our previously identified candidates: regenerating islet-derived 1 beta (REG1B), syncollin (SYCN), anterior gradient homolog 2 protein (AGR2), and lysyl oxidase-like 2 (LOXL2).
The candidate biomarkers were validated using enzyme-linked immunosorbent assays in two sample sets of serum/plasma comprising a total of 432 samples (Sample Set A: pancreatic ductal adenocarcinoma (PDAC, n = 100), healthy (n = 92); Sample Set B: PDAC (n = 82), benign (n = 41), disease-free (n = 47), other cancers (n = 70)). Biomarker performance in distinguishing PDAC from each control group was assessed individually in the two sample sets. Subsequently, multiparametric modeling was applied to assess the ability of all possible two and three marker panels in distinguishing PDAC from disease-free controls. The models were generated using sample set B, and then validated in Sample Set A.
Individually, all markers were significantly elevated in PDAC compared to healthy controls in at least one sample set (p ≤ 0.01). SYCN, REG1B and AGR2 were also significantly elevated in PDAC compared to benign controls (p ≤ 0.01), and AGR2 was significantly elevated in PDAC compared to other cancers (p < 0.01). CA19.9 was also assessed. Individually, CA19.9 showed the greatest area under the curve (AUC) in receiver operating characteristic (ROC) analysis when compared to the tested candidates; however when analyzed in combination, three panels (CA19.9 + REG1B (AUC of 0.88), CA19.9 + SYCN + REG1B (AUC of 0.87) and CA19.9 + AGR2 + REG1B (AUC of 0.87)) showed an AUC that was significantly greater (p < 0.05) than that of CA19.9 alone (AUC of 0.82). In a comparison of early-stage (Stage I-II) PDAC to disease free controls, the combination of SYCN + REG1B + CA19.9 showed the greatest AUC in both sample sets, (AUC of 0.87 and 0.92 in Sets A and B, respectively).
Additional serum biomarkers, particularly SYCN and REG1B, when combined with CA19.9, show promise as improved diagnostic indicators of pancreatic cancer, which therefore warrants further validation.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK