•PD-L1 ≥ 1% is expressed in 16% of stage IV LCNEC, 5% has expression ≥50%.•PD-L1 staining in LCNEC is comparable to values in SCLC, but lower than in NSCLC.•No difference in PD-L1 expression is found ...in RB1 mutated and RB1 wildtype subgroups.•Expression of PD-L1 (tumor cells) and CD8 (tumor infiltrating cells) is associated.•Overall survival is prolonged in patients with PD-L1+ and CD8+ LCNEC.
Pulmonary large cell neuroendocrine carcinoma (LCNEC) is a rare tumor with high mutational burden. Two subtypes of LCNEC are recognized, the co-mutated TP53 and RB1 group and the TP53 and STK11/KEAP1 group. We investigated PD-L1 and CD8 expression in a well characterized stage IV LCNEC cohort and compared expression in the two subtypes.
Immunohistochemical (IHC) analysis for PD-L1 and CD8 was performed on pathological reviewed pretreatment tumor samples for 148 stage IV LCNEC. Data about targeted next generation sequencing (TNGS) (TP53, RB1, STK11, KEAP1) and IHC for RB1 were available for most tumors. IHC staining for PD-L1 (DAKO 28-8) was performed and scored positive if tumors showed ≥1% membranous staining. CD8 was scored for intra-tumor T-cells and stromal cells.
PD-L1 IHC expression data could be generated in 98/148 confirmed LCNEC samples along with RB1 IHC (n = 97) of which 77 passed quality control for TNGS. PD-L1 expression was positive in 16/98 cases (16%); 5 (5%) with ≥50%. PD-L1 expression was equal in RB1 mutated and RB1 wildtype tumors. None of STK11 mutated tumors (n = 7) expressed PD-L1. PD-L1 expression was correlated with superior overall survival (OS), hazard ratio 0.55 ((95% Confidence Interval 0.31-0.96), p = 0.038). Intra-tumor CD8 was associated with PD-L1 expression (p = 0.021) and stromal and intra-tumor CD8 were correlated with improved OS (p = 0.037 and p = 0.026 respectively).
PD-L1 expression was positive in 16% of stage IV LCNEC tumors. This was independent of molecular subtype but associated with CD8 expression. In LCNEC patients with PD-L1 and/or CD8 expression superior OS was observed.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Up to 14% of large cell neuroendocrine carcinomas (LCNECs) are diagnosed in continuity with nonsmall cell lung carcinoma. In addition to these combined lesions, 1% to 7% of lung tumors present as ...co-primary tumors with multiple synchronous lesions. We evaluated molecular and clinicopathological characteristics of combined and co-primary LCNEC-adenocarcinoma (ADC) tumors. Ten patients with LCNEC-ADC (combined) and five patients with multiple synchronous ipsilateral LCNEC and ADC tumors (co-primary) were included. DNA was isolated from distinct tumor parts, and 65 cancer genes were analyzed by next generation sequencing. Immunohistochemistry was performed including neuroendocrine markers, pRb, Ascl1 and Rest. Pure ADC (N = 37) and LCNEC (N = 17) cases were used for reference. At least 1 shared mutation, indicating tumor clonality, was found in LCNEC- and ADC-parts of 10/10 combined tumors but only in 1/5 co-primary tumors. A range of identical mutations was observed in both parts of combined tumors: 8/10 contained ADC-related (EGFR/KRAS/STK11 and/or KEAP1), 4/10 RB1 and 9/10 TP53 mutations. Loss of pRb IHC was observed in 6/10 LCNEC- and 4/10 ADC-parts. The number and intensity of expression of Ascl1 and neuroendocrine markers increased from pure ADC (low) to combined ADC (intermediate) and combined and pure LCNEC (high). The opposite was true for Rest expression. In conclusion, all combined LCNEC-ADC tumors were clonally related indicating a common origin. A relatively high frequency of pRb inactivation was observed in both LCNEC- and ADC-parts, suggesting an underlying role in LCNEC-ADC development. Furthermore, neuroendocrine differentiation might be modulated by Ascl1(+) and Rest(-) expression.
Full text
Available for:
BFBNIB, FZAB, GIS, IJS, KILJ, NLZOH, NUK, OILJ, SBCE, SBMB, UL, UM, UPUK
An Ultra-Low-Cost RCL-Meter Inácio, Pedro M C; Guerra, Rui; Stallinga, Peter
Sensors (Basel, Switzerland),
03/2022, Volume:
22, Issue:
6
Journal Article
Peer reviewed
Open access
An ultra-low-cost RCL meter, aimed at IoT applications, was developed, and was used to measure electrical components based on standard techniques without the need of additional electronics beyond the ...AVR® micro-controller hardware itself and high-level routines. The models and pseudo-routines required to measure admittance parameters are described, and a benchmark between the ATmega328P and ATmega32U4 AVR® micro-controllers was performed to validate the resistance and capacitance measurements. Both ATmega328P and ATmega32U4 micro-controllers could measure isolated resistances from 0.5 Ω to 80 MΩ and capacitances from 100 fF to 4.7 mF. Inductance measurements are estimated at between 0.2 mH to 1.5 H. The accuracy and range of the measurements of series and parallel RC networks are demonstrated. The relative accuracy (ar) and relative precision (pr) of the measurements were quantified. For the resistance measurements, typically ar, pr < 10% in the interval 100 Ω−100 MΩ. For the capacitance, measured in one of the modes (fast mode), ar < 20% and pr < 5% in the range 100 fF−10 nF, while for the other mode (transient mode), typically ar < 20% in the range 10 nF−10 mF and pr < 5% for 100 pF−10 mF. ar falls below 5% in some sub-ranges. The combination of the two capacitance modes allows for measurements in the range 100 fF−10 mF (11 orders of magnitude) with ar < 20%. Possible applications include the sensing of impedimetric sensor arrays targeted for wearable and in-body bioelectronics, smart agriculture, and smart cities, while complying with small form factor and low cost.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
Point spread function (PSF) engineering is used in single emitter localization to measure the emitter position in 3D and possibly other parameters such as the emission color or dipole orientation as ...well. Advanced PSF models such as spline fits to experimental PSFs or the vectorial PSF model can be used in the corresponding localization algorithms in order to model the intricate spot shape and deformations correctly. The complexity of the optical architecture and fit model makes PSF engineering approaches particularly sensitive to optical aberrations. Here, we present a calibration and alignment protocol for fluorescence microscopes equipped with a spatial light modulator (SLM) with the goal of establishing a wavefront error well below the diffraction limit for optimum application of complex engineered PSFs. We achieve high-precision wavefront control, to a level below 20 mλ wavefront aberration over a 30 minute time window after the calibration procedure, using a separate light path for calibrating the pixel-to-pixel variations of the SLM, and alignment of the SLM with respect to the optical axis and Fourier plane within 3 μm (x/y) and 100 μm (z) error. Aberrations are retrieved from a fit of the vectorial PSF model to a bead z-stack and compensated with a residual wavefront error comparable to the error of the SLM calibration step. This well-calibrated and corrected setup makes it possible to create complex '3D+λ' PSFs that fit very well to the vectorial PSF model. Proof-of-principle bead experiments show precisions below 10 nm in x, y, and λ, and below 20 nm in z over an axial range of 1 μm with 2000 signal photons and 12 background photons.
Carrier multiplication is demonstrated in a solid-state dispersion of germanium nanocrystals in a silicon-dioxide matrix. This is performed by comparing ultrafast photo-induced absorption transients ...at different pump photon energies below and above the threshold energy for this process. The average germanium nanocrystal size is approximately 5-6 nm, as inferred from photoluminescence and Raman spectra. A carrier multiplication efficiency of approximately 190% is measured for photo-excitation at 2.8 times the optical bandgap of germanium nanocrystals, deduced from their photoluminescence spectra.
Abstract An ever-increasing amount of data on a person’s daily functioning is being collected, which holds information to revolutionize person-centered healthcare. However, the full potential of data ...on daily functioning cannot yet be exploited as it is mostly stored in an unstructured and inaccessible manner. The integration of these data, and thereby expedited knowledge discovery, is possible by the introduction of functionomics as a complementary ‘omics’ initiative, embracing the advances in data science. Functionomics is the study of high-throughput data on a person’s daily functioning, that can be operationalized with the International Classification of Functioning, Disability and Health (ICF). A prerequisite for making functionomics operational are the FAIR (Findable, Accessible, Interoperable, and Reusable) principles. This paper illustrates a step by step application of the FAIR principles for making functionomics data machine readable and accessible, under strictly certified conditions, in a practical example. Establishing more FAIR functionomics data repositories, analyzed using a federated data infrastructure, enables new knowledge generation to improve health and person-centered healthcare. Together, as one allied health and healthcare research community, we need to consider to take up the here proposed methods.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
We investigate photoluminescence of Eu-related emission in a GaN host consisting of thin layers grown by organometallic vapor-phase epitaxy. By comparing it with a reference sample of Eu-doped Y₂O₃, ...we find that the fraction of Eu(3+) ions that can emit light upon optical excitation is of the order of 1%. We also measure the quantum yield of the Eu-related photoluminescence and find this to reach (~10%) and (~3%) under continuous wave and pulsed excitation, respectively.
Full text
Available for:
IZUM, KILJ, NUK, PILJ, PNG, SAZU, UL, UM, UPUK
We present a new super-resolution technique, Re-scan Confocal Microscopy (RCM), based on standard confocal microscopy extended with an optical (re-scanning) unit that projects the image directly on a ...CCD-camera. This new microscope has improved lateral resolution and strongly improved sensitivity while maintaining the sectioning capability of a standard confocal microscope. This simple technology is typically useful for biological applications where the combination high-resolution and high-sensitivity is required.