The use of charge-reducing reagents to generate lower-charge ions has gained popularity in the field of native mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS). This is because the ...lower number of charged sites decreases the propensity for Coulombic repulsions and unfolding/restructuring, helping to preserve the native-like structure. Furthermore, lowering the charge state consequently increases the mass-to-charge values (m/z), effectively increasing spacing between signals originating from small mass differences, such as different proteoforms or protein–drug complexes. IM-MS yields collision cross section (CCS, Ω) values that provide information about the three-dimensional structure of the ion. Traveling wave IM (TWIM) is an established and expanding technique within the native MS field. TWIM measurements require CCS calibration, which is achieved via the use of standard species of known CCS. Current databases for native-like proteins and protein complexes provide CCS values obtained using normal (i.e., non-charge-reducing) conditions. Herein, we explored the validity of using “normal” charge calibrants to calibrate for charge-reduced proteins and show cases where it is not appropriate. Using a custom linear field drift cell that enables the determination of ion mobilities from “first principles”, we directly determined CCS values for 19 protein calibrant species under three solution conditions (yielding a broad range of charge states) and two drift gases. This has established a database of CCS and reduced-mobility (K 0) values, along with their associated uncertainties, for proteins and protein complexes over a large m/z range. TWIM validation of this database shows improved accuracy over existing methods in calibrating CCS values for charge-reduced proteins.
Full text
Available for:
IJS, KILJ, NUK, PNG, UL, UM
De novo design of transmembrane β barrels Vorobieva, Anastassia A; White, Paul; Liang, Binyong ...
Science (American Association for the Advancement of Science),
02/2021, Volume:
371, Issue:
6531
Journal Article
Peer reviewed
Open access
Transmembrane β-barrel proteins (TMBs) are of great interest for single-molecule analytical technologies because they can spontaneously fold and insert into membranes and form stable pores, but the ...range of pore properties that can be achieved by repurposing natural TMBs is limited. We leverage the power of de novo computational design coupled with a "hypothesis, design, and test" approach to determine TMB design principles, notably, the importance of negative design to slow β-sheet assembly. We design new eight-stranded TMBs, with no homology to known TMBs, that insert and fold reversibly into synthetic lipid membranes and have nuclear magnetic resonance and x-ray crystal structures very similar to the computational models. These advances should enable the custom design of pores for a wide range of applications.
A second-generation (“Gen 2”) device capable of surface-induced dissociation (SID) and collision-induced dissociation (CID) for Fourier transform ion cyclotron resonance mass spectrometry of protein ...complexes has been designed, simulated, fabricated, and experimentally compared to a first-generation device (“Gen 1”). The primary goals of the redesign were to (1) simplify SID by reducing the number of electrodes, (2) increase CID and SID sensitivity by lengthening the collision cell, and (3) increase the mass range of the device for analysis of larger multimeric proteins, all while maintaining the normal instrument configuration and operation. Compared to Gen 1, Gen 2 exhibits an approximately 10× increase in sensitivity in flythrough mode, 7× increase in CID sensitivity for protonated leucine enkephalin (m/z 556), and 14× increase of CID sensitivity of 53 kDa streptavidin tetramer. It also approximately doubles the useful mass range (from m/z 8000 to m/z 15 000) using a rectilinear ion trap with a smaller inscribed radius or triples it (to m/z 22 000) using a hexapole collision cell and yields a 3–10× increase in SID sensitivity. We demonstrate the increased mass range and sensitivity on a variety of model molecules spanning nearly 3 orders of magnitude in absolute mass and present examples where the high resolution of the FT-ICR is advantageous for deconvoluting overlapping SID fragments.
Full text
Available for:
IJS, KILJ, NUK, PNG, UL, UM
The use of submicrometer capillaries for nanoelectrospray ionization of native proteins and protein complexes effectively reduces the number of nonspecific salt adducts to biological molecules, ...therefore increasing the apparent resolution of a mass spectrometer without any further instrument modifications or increased ion activation. However, the increased interaction between proteins and the surface of the capillary has been shown to promote protein expansion and therefore loss of native structure. Here, we compare the effect of micrometer and submicrometer sized capillaries on the native structures of the protein complexes streptavidin, concanavalin A, and C-reactive protein under charge reducing conditions. We observe that the use of submicrometer capillaries did not result in a significantly higher charge state distribution, indicative of expansion, when compared to micrometer sized capillaries for complexes in 100 mM ammonium acetate and 100 mM triethylammonium acetate and for streptavidin in 200 mM ammonium acetate with no charge reduction. Additionally, no significant differences in collision cross sections were observed using ion mobility mass spectrometry. Finally, the dissociation behaviors of protein complexes ionized using micrometer and submicrometer capillaries were compared to determine if any structural perturbation occurred during ionization. Protein complexes from both capillary sizes displayed similar surface-induced dissociation patterns at similar activation energies. The results suggest that submicrometer capillaries do not result in significant changes to protein complex structure under charge reducing conditions and may be used for native mass spectrometry experiments. Submicrometer capillaries can be used to resolve small mass differences of biological systems on a QTOF platform; however, a laser tip puller is required for pulling reproducible submicrometer capillaries, and disruption in spray due to clogging was observed for larger protein complexes.
Full text
Available for:
IJS, KILJ, NUK, PNG, UL, UM
Ultraviolet photodissociation (UVPD) has emerged as a useful technique for characterizing peptide, protein, and protein complex primary and secondary structure. 193 nm UVPD, specifically, enables ...extensive covalent fragmentation of the peptide backbone without the requirement of a specific side chain chromophore and with no precursor charge state dependence. We have modified a commercial quadrupole-ion mobility-time-of-flight (Q-IM-TOF) mass spectrometer to include 193 nm UVPD following ion mobility. Ion mobility (IM) is a gas-phase separation technique that enables separation of ions by their size, shape, and charge, providing an orthogonal dimension of separation to mass analysis. Following instrument modifications, we characterized the performance of, and information that could be generated from, this new setup using the model peptides substance P, melittin, and insulin chain B. These experiments show extensive fragmentation across the peptide backbone and a variety of ion types as expected from 193 nm UVPD. Additionally, y-2 ions (along with complementary a+2 and b+2 ions) N-terminal to proline were observed. Combining the IM separation and mobility gating capabilities with UVPD, we demonstrate the ability to accomplish both mass- and mobility-selection of bradykinin des-Arg9 and des-Arg1 peptides followed by complete sequence characterization by UVPD. The new capabilities of this modified instrument demonstrate the utility of combining IM with UVPD because isobaric species cannot be independently selected with a traditional quadrupole alone.
Full text
Available for:
IJS, KILJ, NUK, PNG, UL, UM, UPUK
A Tilted Surface and Ion Carpet Array for SID Stiving, Alyssa Q; Gilbert, Joshua D; Jones, Benjamin J ...
Journal of the American Society for Mass Spectrometry,
02/2020, Volume:
31, Issue:
2
Journal Article
Peer reviewed
Open access
The development of native mass spectrometry (MS) has provided structural biologists an additional tool to probe the structures of large macromolecular systems. Surface-induced dissociation (SID) is ...one activation method used within tandem MS experiments that has proven useful in interrogating the connectivity and topology of biologically-relevant protein complexes. We present here the use of a tilted surface and ion carpet array within a new SID device design, enabling decreased dimensions along the ion path and fewer lenses to tune. This device works well in fragmenting ions of both low (peptides) and high (protein complexes) m/z. Results show that the ion carpet array, while enabling simplification of the back-end of the device, has deficiencies in product collection and subsequently signal at higher SID energies when fragmenting protein complexes. However, the use of the tilted surface is advantageous as an effective way to shorten the device and reduce the number of independent voltages.
Full text
Available for:
IJS, KILJ, NUK, PNG, UL, UM, UPUK
Monitoring and quantifying host cell proteins (HCPs) in biotherapeutic production processes is crucial to ensure product quality, stability, and safety. Liquid chromatography-mass spectrometry ...(LC-MS) analysis has emerged as an important tool for identifying and quantifying individual HCPs. However, LC-MS-based approaches face challenges due to the wide dynamic range between HCPs and the therapeutic protein as well as laborious sample preparation and long instrument time. To address these limitations, we evaluated the application of parallel accumulation-serial fragmentation combined with data-independent acquisition (diaPASEF) to HCP analysis for biopharmaceutical process development applications. We evaluated different library generation strategies and LC methods, demonstrating the suitability of these workflows for various HCP analysis needs, such as in-depth characterization and high-throughput analysis of process intermediates. Remarkably, the diaPASEF approach enabled the quantification of hundreds of HCPs that were undetectable by a standard data-dependent acquisition mode while considerably improving sample requirement, throughput, coverage, quantitative precision, and data completeness.Monitoring and quantifying host cell proteins (HCPs) in biotherapeutic production processes is crucial to ensure product quality, stability, and safety. Liquid chromatography-mass spectrometry (LC-MS) analysis has emerged as an important tool for identifying and quantifying individual HCPs. However, LC-MS-based approaches face challenges due to the wide dynamic range between HCPs and the therapeutic protein as well as laborious sample preparation and long instrument time. To address these limitations, we evaluated the application of parallel accumulation-serial fragmentation combined with data-independent acquisition (diaPASEF) to HCP analysis for biopharmaceutical process development applications. We evaluated different library generation strategies and LC methods, demonstrating the suitability of these workflows for various HCP analysis needs, such as in-depth characterization and high-throughput analysis of process intermediates. Remarkably, the diaPASEF approach enabled the quantification of hundreds of HCPs that were undetectable by a standard data-dependent acquisition mode while considerably improving sample requirement, throughput, coverage, quantitative precision, and data completeness.
Full text
Available for:
IJS, KILJ, NUK, PNG, UL, UM
The use of charge-reducing reagents to generate lower-charge ions has gained popularity in the field of native mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS). This is because the ...lower number of charged sites decreases the propensity for Coulombic repulsions and unfolding, helping to preserve the native-like structure. Furthermore, lowering the charge state consequently increases the mass-to-charge values (m/z), effectively increasing spacing between signals originating from small mass differences, such as different proteoforms or protein-drug complexes. IM-MS yields collision cross section (CCS, Ω) values that provide information about the three-dimensional structure of the ion. Travelling wave IM (TWIM) is an established and expanding technique within the native MS field. TWIM measurements require CCS calibration, which is achieved via the use of standard species of known CCS. Current databases for native-like proteins and protein complexes provide CCS values obtained using normal (i.e., non-charge-reducing) conditions. Herein, we explored the validity of using “normal” charge calibrants to calibrate for charge-reduced proteins and show cases where it is not appropriate. Using a custom linear field drift cell that enables the determination of ion mobilities from first principles, we directly determined CCS values for 19 protein calibrant species under 3 solution conditions (yielding a broad range of charge states) and 2 drift gases. This has established a database of CCS and reduced-mobility (K
0
) values, along with their associated uncertainties, for proteins and protein complexes over a large
m/z
range. TWIM validation of this database shows improved accuracy over existing methods in calibrating charge-reduced proteins.
Full text
Available for:
IJS, KILJ, NUK, PNG, UL, UM
Live virus vaccine (LVV) purification, employing chromatography, can be challenged by low binding capacities and elution yields. Alternatively, processes relying solely on enzymatic digestion steps ...and size‐based membrane separations can be limited by suboptimal reduction of process related impurities and poorly scalable unit operations. Here, we demonstrate that the combination of flowthrough mode chromatography and an ultrafiltration/diafiltration (UF/DF) unit operation delivers a purification process for two different LVV candidates, V590 and Measles, expressed in adherent Vero cells. For V590, chromatography with mixed mode cation exchange resins returned final product yields of ∼50% and logarithmic reduction values (LRVs) of 1.7–>3.4 and 2.5–3.0 for host cell DNA (hcDNA) and host cell proteins (HCPs), respectively. For Measles, chromatography with mixed mode anion exchange resins returned final product yields of ∼50% and LRVs of 1.6 and 2.2 for hcDNA and HCPs, respectively. For both V590 and Measles processing, the employed resins cleared a key HCP, fibronectin, which could foul the UF/DF unit operation, and thusly enabling it to further reduce HCPs and to formulate the final LVV products. This integrated purification process utilizes the complementary action of the two unit operations and its applicability across LVVs supports its consideration for their processing.
Full text
Available for:
BFBNIB, FZAB, GIS, IJS, KILJ, NLZOH, NUK, OILJ, SAZU, SBCE, SBMB, UL, UM, UPUK