Arrays of single photon avalanche diodes (SPADs) fabricated in a 150 nm CMOS technology have been exposed to neutrons up to fluences of about <inline-formula> <tex-math notation="LaTeX">4.3 \times ...10^{10}~1 </tex-math></inline-formula> MeV neutron equivalent cm<inline-formula> <tex-math notation="LaTeX">^{-2} </tex-math></inline-formula>, with fluxes around <inline-formula> <tex-math notation="LaTeX">3 \times 10^{6}~1 </tex-math></inline-formula> MeV neutron equivalent cm<inline-formula> <tex-math notation="LaTeX">^{-2}\text{s}^{-1} </tex-math></inline-formula>. Dark count rate (DCR) was monitored during irradiation and for some time, from 5 to 23 min, depending on the irradiation step, at the end of the irradiation interval to investigate the dynamics of defect formation and short-term annealing. Measurements were performed both on single- and on dual-layer devices, where SPAD arrays are face to face bonded and read out in coincidence. A range of different DCR behaviors were detected after single neutron interaction with the device substrate, including in particular partial performance recovery following a logarithmic relaxation process, but also damped oscillation phenomena, sudden step-shaped changes, and the emergence of RTS-like fluctuations, pointing to different defect reordering dynamics.
Abstract
The multi-TeV energy region of the cosmic-ray spectra has
been recently explored by direct detection experiments that used
calorimetric techniques to measure the energy of the cosmic
...particles. Interesting spectral features have been observed in both
all-electron and nuclei spectra. However, the interpretation of the
results is compromised by the disagreements between the data
obtained from the various experiments, that are not reconcilable
with the quoted experimental uncertainties. Understanding the
reason for the discrepancy among the measurements is of fundamental
importance in view of the forthcoming high-energy cosmic-ray
experiments planned for space, as well as for the correct
interpretation of the available results.
The purpose of this work is to investigate the possibility that a
systematic effect may derive from the non-proportionality of the
light response of inorganic crystals, typically used in high-energy
calorimetry due to their excellent energy-resolution performance.
The main reason for the non-proportionality of the crystals is that
scintillation light yield depends on ionisation density.
Experimental data obtained with ion beams were used to characterize
the light response of various scintillator materials. The obtained
luminous efficiencies were used as input of a Monte Carlo simulation
to perform a comparative study of the effect of the light-yield
non-proportionality on the detection of high-energy electromagnetic
and hadronic showers. The result of this study indicates that, if
the calorimeter response is calibrated by using the energy deposit
of minimum ionizing particles, the measured shower energy might be
affected by a significant systematic shift, at the level of few
percent, whose sign and magnitude depend specifically on the type of
scintillator material used.
The direct observation of high-energy cosmic rays, up to the PeV energy region, will increasingly rely on highly performing calorimeters, and the physics performance will be primarily determined by ...their geometrical acceptance and energy resolution. Thus, it is extremely important to optimize their geometrical design, granularity and absorption depth, with respect to the total mass of the apparatus, which is amongst the most important constraints for a space mission. CaloCube is an homogeneous calorimeter whose basic geometry is cubic and isotropic, obtained by filling the cubic volume with small cubic scintillating crystals. In this way it is possible to detect particles arriving from every direction in space, thus maximizing the acceptance. This design summarizes a three-year R&D activity, aiming to both optimize and study the full-scale performance of the calorimeter, in the perspective of a cosmic-ray space mission, and investigate a viable technical design by means of the construction of several sizable prototypes. A large scale prototype, made of a mesh of 5 × 5 × 18 CsI(Tl) crystals, has been constructed and tested on high-energy particle beams at CERN SPS accelerator. In this paper we describe the CaloCube design and present the results relative to the response of the large scale prototype to electrons.
Current research in High Energy Cosmic Ray Physics touches on fundamental questions regarding the origin of cosmic rays, their composition, the acceleration mechanisms, and their production. ...Unambiguous measurements of the energy spectra and of the composition of cosmic rays at the “knee” region could provide some of the answers to the above questions. So far only ground based observations, which rely on sophisticated models describing high energy interactions in the Earth's atmosphere, have been possible due to the extremely low particle rates at these energies. A calorimetry based space experiment that could provide not only flux measurements but also energy spectra and particle identification, would certainly overcome some of the uncertainties of ground based experiments. Given the expected particle fluxes, a very large acceptance is needed to collect a sufficient quantity of data, in a time compatible with the duration of a space mission. This in turn, contrasts with the lightness and compactness requirements for space based experiments. We present a novel idea in calorimetry which addresses these issues whilst limiting the mass and volume of the detector. In this paper we report on a four year R&D program where we investigated materials, coatings, photo-sensors, Front End electronics, and mechanical structures with the aim of designing a high performance, high granularity calorimeter with the largest possible acceptance. Details are given of the design choices, component characterisation, and of the construction of a sizeable prototype (Calocube) which has been used in various tests with particle beams.
Photon counting with a FDIRC Cherenkov prototype readout by SiPM arrays Marrocchesi, P.S.; Bagliesi, M.G.; Basti, A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2017, Volume:
845
Journal Article
Peer reviewed
A prototype of a Focused Internal Reflection Cherenkov, equipped with 16 arrays of NUV-SiPM, was tested at CERN SPS in March 2015 with beams of relativistic ions at 13, 19 and 30GeV/n obtained from ...fragmentation of an Ar primary beam. The detector, designed to identify cosmic nuclei, features a Fused Silica radiator bar optically connected to a cylindrical mirror of the same material and an imaging focal plane of dimensions ∼4cm×3cm covered with a total of 1024 SiPM photosensors. Thanks to the outstanding performance of the SiPM arrays, the detector could be operated in photon counting mode as a fully digital device. The Cherenkov pattern was recorded together with the total number of detected photoelectrons increasing as Z2 as a function of the atomic number Z of the beam particle. In this paper, we report on the characterization and test of the SiPM arrays and the performance of the Cherenkov prototype for the charge identification of the beam particles.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK, ZRSKP
The direct detection of high-energy cosmic rays up to the PeV region is one of the major challenges for the next generation of space-borne cosmic-ray detectors. The physics performance will be ...primarily determined by their geometrical acceptance and energy resolution. CaloCube is a homogeneous calorimeter whose geometry allows an almost isotropic response, so as to detect particles arriving from every direction in space, thus maximizing the acceptance. A comparative study of different scintillating materials and mechanical structures has been performed by means of Monte Carlo simulation. The scintillation-Cherenkov dual read-out technique has been also considered and its benefit evaluated.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK, ZRSKP
The CALorimetric Electron Telescope CALET is collecting science data on the International Space Station since October 2015 with excellent and continuous performance. Energy is measured with a deep ...homogeneous calorimeter (1.2 nuclear interaction lengths, 27 radiation lengths) preceded by an imaging pre-shower (3 radiation lengths, 1mm granularity) providing tracking and
electron/proton discrimination. Two independent sub-systems identify the charge
of the incident particle from proton to iron and above (
40). CALET measures the cosmic-ray electron + positron flux up to 20 TeV, gamma rays up to 10 TeV, and nuclei up to the PeV scale. In this paper, we report the on-orbit performance of the instrument and summarize the main results obtained during the first 5 years of operation, including the electron + positron energy spectrum and the individual spectra of protons, heavier nuclei and iron. Solar modulation and gamma-ray observations are also concisely reported, as well as transient phenomena and the search for gravitational wave counterparts.
Full text
Available for:
DOBA, EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, IZUM, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, SIK, UILJ, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
A multi-messenger, space-based cosmic ray detector for gamma rays and charged particles poses several design challenges due to the different instrumental requirements for the two kind of particles. ...Gamma-ray detection requires layers of high Z materials for photon conversion and a tracking device with a long lever arm to achieve the necessary angular resolution to separate point sources; on the contrary, charge measurements for atomic nuclei requires a thin detector in order to avoid unwanted fragmentation, and a shallow instrument so to maximize the geometric factor. In this paper, a novel tracking approach for gamma rays which tries to reconcile these two conflicting requirements is presented. The proposal is based on the Tracker-In-Calorimeter (TIC) design that relies on a highly-segmented calorimeter to track the incident gamma ray by sampling the lateral development of the electromagnetic shower at different depths. The effectiveness of this approach has been studied with Monte Carlo simulations and has been validated with test beam data of a detector prototype.
Given the good performances in terms of geometrical acceptance and energy resolution, calorimeters are the best suited detectors to measure high energy cosmic rays directly in space. However, in ...order to exploit this potential, the design of calorimeters must be carefully optimized to take into account all limitations related to space missions, due mainly to the mass of the experimental apparatus. CaloCube is a three years R&D project, approved and financed by INFN in 2014, aiming to optimize the design of a space-borne calorimeter by the use of a cubic, homogeneous and isotropic geometry. In order to maximize detector performances with respect to the total mass of the apparatus, comparative studies on different scintillating materials, different sizes of crystals and different spacings among them have been performed making use of Monte Carlo simulations. In parallel to this activity, several prototypes instrumented with CsI:Tl cubic crystals have been constructed and tested with particle beams (muons, electrons, protons and ions). Both simulations and prototypes showed that the CaloCube design leads to a good particle energy resolution (< 2% for electromagnetic showers, < 40% for hadronic showers) and a good effective geometric factor (> 3:5 m2 sr for electromagnetic showers, > 2:5 m2 sr for hadronic showers). Thanks to these performances, in 5 years of operation it would be possible to measure the ux of electrons+positrons up to some tens of TeV and the uxes of protons and nuclei up to some units of PeV/nucleon, hence extending these measurements by at least one order of magnitude in energy compared to the experiments currently operating in space.
The CALorimetric Electron Telescope (CALET) is an astroparticle physics experiment installed on the International Space Station since August 2015. The CALET mission was conceived to address several ...outstanding questions of high-energy astroparticle physics, like indirect detection of dark matter, the origin of cosmic rays (CRs), their mechanisms of acceleration and galactic propagation, the presence of possible nearby astrophysical CR sources. That can be achieved by precise measurements of the fluxes of CR electrons and gamma-rays up to the unexplored region above 1 TeV, and the energy spectra and composition of CR nuclei from a few tens of GeV to hundreds of TeV. In order to perform these observations, the instrument combines a thick total absorption PWO crystal calorimeter for energy measurement, a scintillator hodoscope for charge identi cation and thin imaging tungsten-scintillating fiber calorimeter providing accurate particle tracking and complementary charge measurement.
In this paper, we will present an overview of the main CALET results based on the data collected in the first three years of the mission.
Full text
Available for:
DOBA, EMUNI, FIS, FZAB, GEOZS, GIS, IJS, IMTLJ, IZUM, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, SIK, UILJ, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ