We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 tonne-years and an unprecedentedly low background ...rate of 76 ± 2stat events/(tonne × year × keVÞ between 1 and 30 keV, the data enable one of the most sensitive searches for solar axions, an enhanced neutrino magnetic moment using solar neutrinos, and bosonic dark matter. An excess over known backgrounds is observed at low energies and most prominent between 2 and 3 keV. The solar axion model has a 3.4σ significance, and a three-dimensional 90% confidence surface is reported for axion couplings to electrons, photons, and nucleons. This surface is inscribed in the cuboid defined by gae < 3.8 × 10−12, ..., and gaegaγ < 7.7 × 10−22 GeV−1, and excludes either gae = 0 or ... . The neutrino magnetic moment signal is similarly favored over background at 3.2σ, and a confidence interval of μν ∈ (1.4, 2.9) × 10−11 μB (90% C.L.) is reported. Both results are in strong tension with stellar constraints. The excess can also be explained by β decays of tritium at 3.2σ significance with a corresponding tritium concentration in xenon of (6.2 ± 2.0) × 10−25 mol/mol. Such a trace amount can neither be confirmed nor excluded with current knowledge of its production and reduction mechanisms. The significances of the solar axion and neutrino magnetic moment hypotheses are decreased to 2.0σ and 0.9σ, respectively, if an unconstrained tritium component is included in the fitting. With respect to bosonic dark matter, the excess favors a monoenergetic peak at (2.3 ± 0.2) keV (68% C.L.) with a 3.0σ global (4.0σ local) significance over background. This analysis sets the most restrictive direct constraints to date on pseudoscalar and vector bosonic dark matter for most masses between 1 and 210 keV/c2. We also consider the possibility that 37Ar may be present in the detector, yielding a 2.82 keV peak from electron capture. Contrary to tritium, the 37Ar concentration can be tightly constrained and is found to be negligible. (ProQuest: ... denotes formula omitted.)
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
We report constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment. We mitigate backgrounds with strong event selections, rather than requiring a scintillation ...signal, leaving an effective exposure of (22±3) tonne day. Above ∼0.4 keV_{ee}, we observe <1 event/(tonne day keV_{ee}), which is more than 1000 times lower than in similar searches with other detectors. Despite observing a higher rate at lower energies, no DM or CEvNS detection may be claimed because we cannot model all of our backgrounds. We thus exclude new regions in the parameter spaces for DM-nucleus scattering for DM masses m_{χ} within 3-6 GeV/c^{2}, DM-electron scattering for m_{χ}>30 MeV/c^{2}, and absorption of dark photons and axionlike particles for m_{χ} within 0.186-1 keV/c^{2}.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UL, UM
We report the first experimental results on spin-dependent elastic weakly interacting massive particle (WIMP) nucleon scattering from the XENON1T dark matter search experiment. The analysis uses the ...full ton year exposure of XENON1T to constrain the spin-dependent proton-only and neutron-only cases. No significant signal excess is observed, and a profile likelihood ratio analysis is used to set exclusion limits on the WIMP-nucleon interactions. This includes the most stringent constraint to date on the WIMP-neutron cross section, with a minimum of 6.3×10^{-42} cm^{2} at 30 GeV/c^{2} and 90% confidence level. The results are compared with those from collider searches and used to exclude new parameter space in an isoscalar theory with an axial-vector mediator.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UL, UM
We report on WIMP search results of the XENON100 experiment, combining three runs summing up to 477 live days from January 2010 to January 2014. Data from the first two runs were already published. A ...blind analysis was applied to the last run recorded between April 2013 and January 2014 prior to combining the results. The ultralow electromagnetic background of the experiment, ∼5×10−3 events/(keVee×kg×day)) before electronic recoil rejection, together with the increased exposure of 48 kg×yr, improves the sensitivity. A profile likelihood analysis using an energy range of (6.6–43.3) keVnr sets a limit on the elastic, spin-independent WIMP-nucleon scattering cross section for WIMP masses above 8 GeV/c2, with a minimum of 1.1×10−45 cm2 at 50 GeV/c2 and 90% confidence level. We also report updated constraints on the elastic, spin-dependent WIMP-nucleon cross sections obtained with the same data. We set upper limits on the WIMP-neutron (proton) cross section with a minimum of 2.0×10−40 cm2 (52×10−40 cm2) at a WIMP mass of 50 GeV/c2, at 90% confidence level.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
We report on a search for electronic recoil event rate modulation signatures in the XENON100 data accumulated over a period of 4 yr, from January 2010 to January 2014. A profile likelihood method, ...which incorporates the stability of the XENON100 detector and the known electronic recoil background model, is used to quantify the significance of periodicity in the time distribution of events. There is a weak modulation signature at a period of 431_{-14}^{+16} day in the low energy region of (2.0-5.8) keV in the single scatter event sample, with a global significance of 1.9σ; however, no other more significant modulation is observed. The significance of an annual modulation signature drops from 2.8σ, from a previous analysis of a subset of this data, to 1.8σ with all data combined. Single scatter events in the low energy region are thus used to exclude the DAMA/LIBRA annual modulation as being due to dark matter electron interactions via axial vector coupling at 5.7σ.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
Panic disorder is a common psychiatric diagnosis characterized by acute, distressing somatic symptoms that mimic medically-relevant symptoms. As a result, individuals with panic disorder overutilize ...personal and healthcare resources in an attempt to diagnose and treat physical symptoms that are often medically benign. A biobehavioral perspective on these symptoms is needed that integrates psychological and medical knowledge to avoid costly treatments and prolonged suffering. This narrative review examines six common somatic symptoms of panic attacks (non-cardiac chest pain, palpitations, dyspnea, dizziness, abdominal distress, and paresthesia), identified in the literature as the most severe, prevalent, or critical for differential diagnosis in somatic illness, including long COVID. We review somatic illnesses that are commonly comorbid or produce panic-like symptoms, their relevant risk factors, characteristics that assist in distinguishing them from panic, and treatment approaches that are typical for these conditions. Additionally, this review discusses key factors, including cultural considerations, to assist healthcare professionals in differentiating benign from medically relevant symptoms in panic sufferers.
The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of
136
Xe. Out of its 50 t total natural xenon inventory, ...40 t will be the active target of a time projection chamber which thus contains about 3.6 t of
136
Xe. Here, we show that its projected half-life sensitivity is
2.4
×
10
27
year
, using a fiducial volume of 5 t of natural xenon and 10 year of operation with a background rate of less than 0.2 events/(t
·
year) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in
136
Xe.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Abstract
The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of
$$^{136}$$
136
Xe. Out of its 50 t total ...natural xenon inventory, 40 t will be the active target of a time projection chamber which thus contains about 3.6 t of
$$^{136}$$
136
Xe. Here, we show that its projected half-life sensitivity is
$$2.4\times {10}^{27}\,{\hbox {year}}$$
2.4
×
10
27
year
, using a fiducial volume of 5 t of natural xenon and 10 year of operation with a background rate of less than 0.2 events/(t
$$\cdot $$
·
year) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in
$$^{136}$$
136
Xe.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. ...We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The precision in reconstructing events detected in a dual-phase time projection chamber depends on an homogeneous and well understood electric field within the liquid target. In the XENONnT TPC the ...field homogeneity is achieved through a double-array field cage, consisting of two nested arrays of field shaping rings connected by an easily accessible resistor chain. Rather than being connected to the gate electrode, the topmost field shaping ring is independently biased, adding a degree of freedom to tune the electric field during operation. Two-dimensional finite element simulations were used to optimize the field cage, as well as its operation. Simulation results were compared to
83
m
Kr
calibration data. This comparison indicates an accumulation of charge on the panels of the TPC which is constant over time, as no evolution of the reconstructed position distribution of events is observed. The simulated electric field was then used to correct the charge signal for the field dependence of the charge yield. This correction resolves the inconsistent measurement of the drift electron lifetime when using different calibrations sources and different field cage tuning voltages.
Full text
Available for:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK