Hemodynamics of Mechanical Circulatory Support Burkhoff, Daniel, MD, PhD; Sayer, Gabriel, MD; Doshi, Darshan, MD ...
Journal of the American College of Cardiology,
12/2015, Volume:
66, Issue:
23
Journal Article
Peer reviewed
Open access
Abstract An increasing number of devices can provide mechanical circulatory support (MCS) to patients with acute hemodynamic compromise and chronic end-stage heart failure. These devices work by ...different pumping mechanisms, have various flow capacities, are inserted by different techniques, and have different sites from which blood is withdrawn and returned to the body. These factors result in different primary hemodynamic effects and secondary responses of the body. However, these are not generally taken into account when choosing a device for a particular patient or while managing a patient undergoing MCS. In this review, we discuss fundamental principles of cardiac, vascular, and pump mechanics and illustrate how they provide a broad foundation for understanding the complex interactions between the heart, vasculature, and device, and how they may help guide future research to improve patient outcomes.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Mechanical Unloading in Heart Failure Uriel, Nir; Sayer, Gabriel; Annamalai, Shiva ...
Journal of the American College of Cardiology,
07/2018, Volume:
72, Issue:
5
Journal Article
Peer reviewed
Open access
Myocardial injury induces significant changes in ventricular structure and function at both the cellular and anatomic level, leading to ventricular remodeling and subsequent heart failure. Unloading ...left ventricular pressure has been studied in both the short-term and long-term settings, as a means of preventing or reversing cardiac remodeling. In acute myocardial infarction, cardiac unloading is used to reduce oxygen demand and limit infarct size. Research has demonstrated the benefits of short-term unloading with mechanical circulatory support devices before reperfusion in the context of acute myocardial infarction with cardiogenic shock, and a confirmatory trial is ongoing. In chronic heart failure, ventricular unloading using mechanical circulatory support can reverse many of the cellular and anatomic changes that accompany ventricular remodeling. Ongoing research is evaluating the ability of left ventricular assist devices to promote myocardial recovery and remission from clinical heart failure.
Display omitted
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
In a randomized trial, 294 patients with advanced heart failure were assigned to receive either a new centrifugal-flow pump or an axial-flow pump. At 6 months, the centrifugal-flow pump was ...associated with better outcomes.
A scarcity of effective therapeutic options for advanced heart failure has led to the development of durable mechanical circulatory support devices. Left ventricular assist devices, more accurately known as left ventricular assist systems, increase the rate of survival and improve quality of life among patients with advanced heart failure. However, these clinical benefits are balanced by an increased risk of infection, bleeding, neurologic events, and pump malfunction that is due principally to pump thrombosis.
1
,
2
As adoption of circulatory pumps has expanded, concerns about pump thrombosis have heightened. In 2013, two reports suggested that there has been an increase in . . .
COVID-19 and Cardiovascular Disease Clerkin, Kevin J; Fried, Justin A; Raikhelkar, Jayant ...
Circulation (New York, N.Y.),
2020-May-19, 2020-05-19, 20200519, Volume:
141, Issue:
20
Journal Article
Peer reviewed
Coronavirus disease 2019 (COVID-19) is a global pandemic affecting 185 countries and >3 000 000 patients worldwide as of April 28, 2020. COVID-19 is caused by severe acute respiratory syndrome ...coronavirus 2, which invades cells through the angiotensin-converting enzyme 2 receptor. Among patients with COVID-19, there is a high prevalence of cardiovascular disease, and >7% of patients experience myocardial injury from the infection (22% of critically ill patients). Although angiotensin-converting enzyme 2 serves as the portal for infection, the role of angiotensin-converting enzyme inhibitors or angiotensin receptor blockers requires further investigation. COVID-19 poses a challenge for heart transplantation, affecting donor selection, immunosuppression, and posttransplant management. There are a number of promising therapies under active investigation to treat and prevent COVID-19.
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the pathogen responsible for the coronavirus disease 2019 (COVID-19) pandemic, which has resulted in global healthcare crises and ...strained health resources. As the population of patients recovering from COVID-19 grows, it is paramount to establish an understanding of the healthcare issues surrounding them. COVID-19 is now recognized as a multi-organ disease with a broad spectrum of manifestations. Similarly to post-acute viral syndromes described in survivors of other virulent coronavirus epidemics, there are increasing reports of persistent and prolonged effects after acute COVID-19. Patient advocacy groups, many members of which identify themselves as long haulers, have helped contribute to the recognition of post-acute COVID-19, a syndrome characterized by persistent symptoms and/or delayed or long-term complications beyond 4 weeks from the onset of symptoms. Here, we provide a comprehensive review of the current literature on post-acute COVID-19, its pathophysiology and its organ-specific sequelae. Finally, we discuss relevant considerations for the multidisciplinary care of COVID-19 survivors and propose a framework for the identification of those at high risk for post-acute COVID-19 and their coordinated management through dedicated COVID-19 clinics.
Full text
Available for:
GEOZS, IJS, IMTLJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBMB, UL, UM, UPUK, ZAGLJ
Although COVID-19 is most well known for causing substantial respiratory pathology, it can also result in several extrapulmonary manifestations. These conditions include thrombotic complications, ...myocardial dysfunction and arrhythmia, acute coronary syndromes, acute kidney injury, gastrointestinal symptoms, hepatocellular injury, hyperglycemia and ketosis, neurologic illnesses, ocular symptoms, and dermatologic complications. Given that ACE2, the entry receptor for the causative coronavirus SARS-CoV-2, is expressed in multiple extrapulmonary tissues, direct viral tissue damage is a plausible mechanism of injury. In addition, endothelial damage and thromboinflammation, dysregulation of immune responses, and maladaptation of ACE2-related pathways might all contribute to these extrapulmonary manifestations of COVID-19. Here we review the extrapulmonary organ-specific pathophysiology, presentations and management considerations for patients with COVID-19 to aid clinicians and scientists in recognizing and monitoring the spectrum of manifestations, and in developing research priorities and therapeutic strategies for all organ systems involved.
Full text
Available for:
FZAB, GEOZS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
Left Ventricular Assist Devices for Lifelong Support Pinney, Sean P., MD; Anyanwu, Anelechi C., MD; Lala, Anuradha, MD ...
Journal of the American College of Cardiology,
06/2017, Volume:
69, Issue:
23
Journal Article
Peer reviewed
Open access
Abstract Continuous-flow left ventricular assist devices (LVADs) have revolutionized advanced heart failure care. These compact, fully implantable heart pumps are capable of providing meaningful ...increases in survival, functional capacity, and quality of life. Implantation volumes continue to grow, but several challenges remain to be overcome before LVADs will be considered as the therapy of choice for all patients with advanced heart failure. They must be able to consistently extend survival for the long term (7 to 10 years), rather than the midterm (3 to 5 years) more typical of contemporary devices; they must incorporate design elements that reduce shear stress and avoid stasis to reduce the frequent adverse events of bleeding, stroke, and pump thrombosis; and they must become more cost-effective. The advancements in engineering, implantation technique, and medical management detailed in this review will highlight the progress made toward achieving lifelong LVAD support and the challenges that remain.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Objectives The objective of the study was to determine the prevalence of bleeding during continuous-flow left ventricular assist device support and to identify potential mechanisms for those bleeding ...events. Background Bleeding is frequently reported with continuous-flow left ventricular assist devices and may result from anticoagulation coupled with bleeding diathesis such as acquired von Willebrand syndrome. Accordingly, the prevalence of coagulation abnormalities including laboratory assessment for von Willebrand syndrome, bleeding events during device support, and at heart transplantation were evaluated. Methods A retrospective study in all HeartMate II (HM II) (Thoratec Corp., Pleasanton, California) patients who underwent implantation between April 1, 2004, and August 1, 2009, was performed. Bleeding was defined as the need for transfusion >7 days after device insertion of 1 U of packed red blood cells. Transfusion at heart transplantation was compared with that in HeartMate XVE patients. Results Seventy-nine HM II devices were implanted. Anticoagulation included warfarin in 68.3%, aspirin in 55.7%, and dipyridamole in 58.2% of the patients. Of the patients, 44.3% had bleeding episodes at 112 ± 183 days after left ventricular assist device implantation, with 50% experiencing an event within 2 months. Gastrointestinal bleeding was the most frequent event. At the index event, the international normalized ratio averaged 1.67 ± 0.53, and the platelet count was 237 ± 119 × 109 /l. Comparison of the transfusion requirements at heart transplantation of 35 HM II patients with 62 HeartMate XVE patients demonstrated twice the transfusion requirements in HM II patients (packed red blood cells, 6.3 ± 0.8 U vs. 3.8 ± 0.5 U; platelets, 12.5 ± 5.4 U vs. 8.6 ± 6.4 U; fresh frozen plasma, 9.6 ± 4.9 U vs. 4.9 ± 3.6 U; and cryoprecipitate, 4.3 ± 3.6 U vs. 2.2 ± 3.5 U; p < 0.05 for all). High molecular weight von Willebrand factor multimers were measured in 31 HM II patients and were reduced in all patients; 18 of these 31 (58%) patients had bleeding. Conclusions Patients with the HM II had a high incidence of bleeding events during device support and at heart transplantation. All HM II patients had reduced high molecular weight von Willebrand factor multimers. The role of these abnormalities in the high incidence of bleeding deserves further investigation. Furthermore, alterations in anticoagulation should be considered during device support and before surgery in patients supported with the HM II.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Solid organ transplant recipients may be at a high risk for SARS‐CoV‐2 infection and poor associated outcomes. We herein report our initial experience with solid organ transplant recipients with ...SARS‐CoV‐2 infection at two centers during the first 3 weeks of the outbreak in New York City. Baseline characteristics, clinical presentation, antiviral and immunosuppressive management were compared between patients with mild/moderate and severe disease (defined as ICU admission, intubation or death). Ninety patients were analyzed with a median age of 57 years. Forty‐six were kidney recipients, 17 lung, 13 liver, 9 heart, and 5 dual‐organ transplants. The most common presenting symptoms were fever (70%), cough (59%), and dyspnea (43%). Twenty‐two (24%) had mild, 41 (46%) moderate, and 27 (30%) severe disease. Among the 68 hospitalized patients, 12% required non‐rebreather and 35% required intubation. 91% received hydroxychloroquine, 66% azithromycin, 3% remdesivir, 21% tocilizumab, and 24% bolus steroids. Sixteen patients died (18% overall, 24% of hospitalized, 52% of ICU) and 37 (54%) were discharged. In this initial cohort, transplant recipients with COVID‐19 appear to have more severe outcomes, although testing limitations likely led to undercounting of mild/asymptomatic cases. As this outbreak unfolds, COVID‐19 has the potential to severely impact solid organ transplant recipients.
In this multicenter study of 90 solid organ transplant recipients diagnosed with COVID‐19 during the first three weeks of the outbreak in New York City, the authors report on the clinical presentation, laboratory abnormalities, risk factors, disease severity, and outcomes.
Full text
Available for:
BFBNIB, FZAB, GEOZS, GIS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP