Fast radio bursts (FRBs) are millisecond-duration radio transients
of unknown origin. Two possible mechanisms that could generate extremely coherent emission from FRBs invoke neutron star ...magnetospheres
or relativistic shocks far from the central energy source
. Detailed polarization observations may help us to understand the emission mechanism. However, the available FRB polarization data have been perplexing, because they show a host of polarimetric properties, including either a constant polarization angle during each burst for some repeaters
or variable polarization angles in some other apparently one-off events
. Here we report observations of 15 bursts from FRB 180301 and find various polarization angle swings in seven of them. The diversity of the polarization angle features of these bursts is consistent with a magnetospheric origin of the radio emission, and disfavours the radiation models invoking relativistic shocks.
Full text
Available for:
FZAB, GEOZS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
Gravitational waves are expected to be radiated by supermassive black hole binaries formed during galaxy mergers. A stochastic superposition of gravitational waves from all such binary systems would ...modulate the arrival times of pulses from radio pulsars. Using observations of millisecond pulsars obtained with the Parkes radio telescope, we constrained the characteristic amplitude of this background, Ac,yr, to be <1.0 × 10–15 with 95% confidence. This limit excludes predicted ranges for Ac,yr from current models with 91 to 99.7% probability. We conclude that binary evolution is either stalled or dramatically accelerated by galactic-center environments and that higher-cadence and shorter-wavelength observations would be more sensitive to gravitational waves.
Full text
Available for:
BFBNIB, NMLJ, NUK, PNG, SAZU, UL, UM, UPUK
Fast radio bursts (FRBs) are millisecond-duration radio transients of unknown physical origin observed at extragalactic distances
. It has long been speculated that magnetars are the engine powering ...repeating bursts from FRB sources
, but no convincing evidence has been collected so far
. Recently, the Galactic magnetar SRG 1935+2154 entered an active phase by emitting intense soft γ-ray bursts
. One FRB-like event with two peaks (FRB 200428) and a luminosity slightly lower than the faintest extragalactic FRBs was detected from the source, in association with a soft γ-ray/hard-X-ray flare
. Here we report an eight-hour targeted radio observational campaign comprising four sessions and assisted by multi-wavelength (optical and hard-X-ray) data. During the third session, 29 soft-γ-ray repeater (SGR) bursts were detected in γ-ray energies. Throughout the observing period, we detected no single dispersed pulsed emission coincident with the arrivals of SGR bursts, but unfortunately we were not observing when the FRB was detected. The non-detection places a fluence upper limit that is eight orders of magnitude lower than the fluence of FRB 200428. Our results suggest that FRB-SGR burst associations are rare. FRBs may be highly relativistic and geometrically beamed, or FRB-like events associated with SGR bursts may have narrow spectra and characteristic frequencies outside the observed band. It is also possible that the physical conditions required to achieve coherent radiation in SGR bursts are difficult to satisfy, and that only under extreme conditions could an FRB be associated with an SGR burst.
Full text
Available for:
FZAB, GEOZS, IJS, IMTLJ, KILJ, KISLJ, MFDPS, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, SBMB, SBNM, UKNU, UL, UM, UPUK, VKSCE, ZAGLJ
Preoperative evaluation of the number of lymph node metastasis (LNM) is the basis of individual treatment of locally advanced gastric cancer (LAGC). However, the routinely used preoperative ...determination method is not accurate enough.
We enrolled 730 LAGC patients from five centers in China and one center in Italy, and divided them into one primary cohort, three external validation cohorts, and one international validation cohort. A deep learning radiomic nomogram (DLRN) was built based on the images from multiphase computed tomography (CT) for preoperatively determining the number of LNM in LAGC. We comprehensively tested the DLRN and compared it with three state-of-the-art methods. Moreover, we investigated the value of the DLRN in survival analysis.
The DLRN showed good discrimination of the number of LNM on all cohorts overall C-indexes (95% confidence interval): 0.821 (0.785–0.858) in the primary cohort, 0.797 (0.771–0.823) in the external validation cohorts, and 0.822 (0.756–0.887) in the international validation cohort. The nomogram performed significantly better than the routinely used clinical N stages, tumor size, and clinical model (P < 0.05). Besides, DLRN was significantly associated with the overall survival of LAGC patients (n = 271).
A deep learning-based radiomic nomogram had good predictive value for LNM in LAGC. In staging-oriented treatment of gastric cancer, this preoperative nomogram could provide baseline information for individual treatment of LAGC.
•Evaluation of the lymph node metastasis (LNM) is the basis of individual treatment of locally advanced gastric cancer (LAGC).•Deep leaning radiomic nomogram (DLRN) based on CT images can preoperatively determine the number of LNM in LAGC.•DLRN is significantly superior to the routinely used clinical N stages, tumor size, and clinical model.•DLRN is significantly associated with the overall survival of LAGC.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NLZOH, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UILJ, UL, UM, UPCLJ, UPUK, ZAGLJ, ZRSKP
Close white dwarf binaries consisting of a white dwarf and an A-, F-, G-, or K-type main-sequence star, henceforth close WD+AFGK binaries, are ideal systems to understand the nature of type Ia ...supernovae progenitors and to test binary evolution models. In this work we identify 775 WD+AFGK candidates from TGAS (The Tycho-Gaia Astrometric Solution) and Gaia Data Release 2 (DR2), a well-defined sample of stars with available parallaxes, and we measure radial velocities (RVs) for 275 of them with the aim of identifying close binaries. The RVs have been measured from high-resolution spectra obtained at the Xinglong 2.16 m Telescope and the San Pedro Mártir 2.12 m Telescope and/or from available LAMOST DR6 (low-resolution) and RAVE DR5 (medium-resolution) spectra. We identify 23 WD+AFGK systems displaying more than 3 RV variation among 151 systems for which the measured values are obtained from different nights. Our WD+AFGK binary sample contains both AFGK dwarfs and giants, with a giant fraction ∼43%. The close binary fractions we determine for the WD+AFGK dwarf and giant samples are 24% and 15%, respectively. We also determine the stellar parameters (i.e., effective temperature, surface gravity, metallicity, mass, and radius) of the AFGK companions with available high-resolution spectra. The stellar parameter distributions of the AFGK companions that are members of close and wide binary candidates do not show statistically significant differences.
Background
Delirium is common in elderly patients after surgery and is associated with poor outcomes. This study aimed to investigate the impact of intraoperative dexmedetomidine on the incidence of ...delirium in elderly patients undergoing major surgery.
Methods
This was a randomized double‐blind placebo‐controlled trial. Elderly patients (aged 60 years or more) scheduled to undergo major non‐cardiac surgery were randomized into two groups. Patients in the intervention group received a loading dose of dexmedetomidine 0·6 μg/kg 10 min before induction of anaesthesia followed by a continuous infusion (0·5 μg per kg per h) until 1 h before the end of surgery. Patients in the control group received volume‐matched normal saline in the same schedule. The primary outcome was the incidence of delirium during the first 5 days after surgery. Delirium was assessed with the Confusion Assessment Method (CAM) for non‐ventilated patients and CAM for the Intensive Care Unit for ventilated patients.
Results
In total, 309 patients who received dexmedetomidine and 310 control patients were included in the intention‐to‐treat analysis. The incidence of delirium within 5 days of surgery was lower with dexmedetomidine treatment: 5·5 per cent (17 of 309) versus 10·3 per cent (32 of 310) in the control group (relative risk (RR) 0·53, 95 per cent c.i. 0·30 to 0·94; P = 0·026). The overall incidence of complications at 30 days was also lower after dexmedetomidine (19·4 per cent (60 of 309) versus 26·1 per cent (81 of 310) for controls; RR 0·74, 0·55 to 0·99, P = 0·047).
Conclusion
Intraoperative dexmedetomidine halved the risk of delirium in the elderly after major non‐cardiac surgery. Registration number: ChiCTR‐IPR‐15007654 (
www.chictr.org.cn).
Antecedentes
El delirio después de la cirugía es frecuente en los pacientes de edad avanzada y se asocia con malos resultados. El objetivo de este estudio fue investigar el impacto de la administración intraoperatoria de dexmedetomidina en la incidencia de delirio en pacientes mayores sometidos a operaciones de cirugía mayor.
Métodos
Se trataba de un ensayo aleatorizado, doble ciego y controlado con placebo. Un total de 620 pacientes mayores (60 años o más) fueron programados para ser sometidos a intervenciones (no cardiacas) de cirugía mayor y se aleatorizaron a dos grupos. Los pacientes en el grupo de intervención recibieron una dosis de carga de dexmedetomidina (0,6 μg/kg, 10 minutos antes de la inducción anestésica) seguida de una infusión continua (0,5 μg/kg/h) hasta 1 h antes de la finalización de la cirugía. Los pacientes del grupo control recibieron el mismo volumen de suero salino siguiendo la misma pauta. El resultado principal era la incidencia de delirio durante los primeros 5 días postoperatorios. Para la valoración del delirio se utilizó el método para la evaluación de la confusión (Confusion Assessment Method, CAM) en pacientes no intubados y el CAM‐UCI para los pacientes intubados.
Resultados
En total, 309 pacientes que recibieron dexmedetomidina y 310 del grupo control se incluyeron en el análisis por intención de tratar. La incidencia de delirio durante los primeros 5 días tras la cirugía fue inferior en presencia de tratamiento con dexmedetomidina que en ausencia del mismo: 5,5% (17/309) versus 10,3% (32/310); riesgo relativo (RR) 0,53, i.c. del 95% 0,30‐0,94, P = 0,026. La incidencia global de complicaciones a los 30 días excluyendo el delirio también fue inferior en presencia que en ausencia de tratamiento con dexmedetomidina (19,4% (60/309) versus 26,1% (81/301), RR 0,74, i.c. del 95% 0,55‐0,99, P = 0,047).
Conclusión
La administración intraoperatoria de dexmedetomidina reduce la presencia de delirio en los pacientes mayores tras cirugía mayor no cardiaca.
In this RCT, intraoperative infusion of dexmedetomidine was found to reduce the rate of postoperative delirium and surgery‐related complications. The shortcomings of previous studies, such as study design and sample size, were amended, providing more robust evidence for clinical practice.
Halved the rate of delirium
Full text
Available for:
BFBNIB, FZAB, GIS, IJS, KILJ, NLZOH, NUK, OILJ, SAZU, SBCE, SBMB, UL, UM, UPUK
Abstract Understanding the jitter noise resulting from single-pulse phase and shape variations is important for the detection of gravitational waves using pulsar timing arrays. We present ...measurements of the jitter noise and single-pulse variability of 12 millisecond pulsars that are part of the International Pulsar Timing Array sample using the Five-hundred-meter Aperture Spherical radio Telescope. We find that the levels of jitter noise can vary dramatically among pulsars. A moderate correlation with a correlation coefficient of 0.57 between jitter noise and pulse width is detected. To mitigate jitter noise, we perform matrix template matching using all four Stokes parameters. Our results reveal a reduction in jitter noise ranging from 6.7% to 39.6%. By performing longitude-resolved fluctuation spectrum analysis, we identify periodic intensity modulations in 10 pulsars. In PSR J0030+0451, we detect single pulses with energies more than 10 times the average pulse energy, suggesting the presence of giant pulses. We also observe a periodic mode-changing phenomenon in PSR J0030+0451. We examine the achievable timing precision by selecting a subset of pulses with a specific range of peak intensity, but no significant improvement in timing precision is achievable.
Two-dimensional (2D) materials have been studied extensively as monolayers, vertical or lateral heterostructures. To achieve functionalization, monolayers are often patterned using soft lithography ...and selectively decorated with molecules. Here we demonstrate the growth of a family of 2D materials that are intrinsically patterned. We demonstrate that a monolayer of PtSe
can be grown on a Pt substrate in the form of a triangular pattern of alternating 1T and 1H phases. Moreover, we show that, in a monolayer of CuSe grown on a Cu substrate, strain relaxation leads to periodic patterns of triangular nanopores with uniform size. Adsorption of different species at preferred pattern sites is also achieved, demonstrating that these materials can serve as templates for selective self-assembly of molecules or nanoclusters, as well as for the functionalization of the same substrate with two different species.
Full text
Available for:
IJS, KISLJ, NUK, SBMB, UL, UM, UPUK
The formation and growth processes of supermassive black holes (SMBHs) are not well constrained. SMBH population models, however, provide specific predictions for the properties of the ...gravitational-wave background (GWB) from binary SMBHs in merging galaxies throughout the universe. Using observations from the Parkes Pulsar Timing Array, we constrain the fractional GWB energy density (Ω GW ) with 95% confidence to be Ω GW (H₀/73 kilometers per second per megaparsec)² < 1.3 × 10⁻⁹ (where H₀ is the Hubble constant) at a frequency of 2.8 nanohertz, which is approximately a factor of 6 more stringent than previous limits. We compare our limit to models of the SMBH population and find inconsistencies at confidence levels between 46 and 91%. For example, the standard galaxy formation model implemented in the Millennium Simulation Project is inconsistent with our limit with 50% probability.
Full text
Available for:
BFBNIB, NMLJ, NUK, PNG, SAZU, UL, UM, UPUK
The highly stable spin of neutron stars can be exploited for a variety of (astro)physical investigations. In particular, arrays of pulsars with rotational periods of the order of milliseconds can be ...used to detect correlated signals such as those caused by gravitational waves. Three such ‘pulsar timing arrays’ (PTAs) have been set up around the world over the past decades and collectively form the ‘International’ PTA (IPTA). In this paper, we describe the first joint analysis of the data from the three regional PTAs, i.e. of the first IPTA data set. We describe the available PTA data, the approach presently followed for its combination and suggest improvements for future PTA research. Particular attention is paid to subtle details (such as underestimation of measurement uncertainty and long-period noise) that have often been ignored but which become important in this unprecedentedly large and inhomogeneous data set. We identify and describe in detail several factors that complicate IPTA research and provide recommendations for future pulsar timing efforts. The first IPTA data release presented here (and available online) is used to demonstrate the IPTA's potential of improving upon gravitational-wave limits placed by individual PTAs by a factor of ∼2 and provides a 2σ limit on the dimensionless amplitude of a stochastic gravitational-wave background of 1.7 × 10−15 at a frequency of 1 yr−1. This is 1.7 times less constraining than the limit placed by Shannon et al., due mostly to the more recent, high-quality data they used.