Free neutron decay is a fundamental process in particle and nuclear physics. It is the prototype for nuclear beta decay and other semileptonic weak particle decays. Neutron decay played a key role in ...the formation of light elements in the early universe. The precise value of the neutron mean lifetime, about 15 min, has been the subject of many experiments over the past 70 years. The two main experimental methods, the beam method and the ultracold neutron storage method, give average values of the neutron lifetime that currently differ by 8.7 s (4 standard deviations), a serious discrepancy. The physics of neutron decay, implications of the neutron lifetime, previous and recent experimental measurements, and prospects for the future are reviewed.
The standard model predicts that, in addition to a proton, an electron, and an antineutrino, a continuous spectrum of photons is emitted in the β decay of the free neutron. We report on the RDK II ...experiment which measured the photon spectrum using two different detector arrays. An annular array of bismuth germanium oxide scintillators detected photons from 14 to 782 keV. The spectral shape was consistent with theory, and we determined a branching ratio of 0.00335±0.00005stat±0.00015syst. A second detector array of large area avalanche photodiodes directly detected photons from 0.4 to 14 keV. For this array, the spectral shape was consistent with theory, and the branching ratio was determined to be 0.00582±0.00023stat±0.00062syst. We report the first precision test of the shape of the photon energy spectrum from neutron radiative decay and a substantially improved determination of the branching ratio over a broad range of photon energies.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
We report the first result for the electron-antineutrino angular correlation (a coefficient) in free neutron β decay from the aCORN experiment. aCORN uses a novel method in which the a coefficient is ...proportional to an asymmetry in proton time of flight for events where the β electron and recoil proton are detected in delayed coincidence. Data are presented from a 15 month run at the NIST Center for Neutron Research. We obtained a=-0.1090±0.0030(stat)±0.0028(sys), the most precise measurement of the neutron a coefficient reported to date.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
We present an apparatus for detection of cyclotron radiation yielding a frequency-based β± kinetic energy determination in the 5 keV to 2.1 MeV range, characteristic of nuclear β decays. The ...cyclotron frequency of the radiating β particles in a magnetic field is used to determine the β energy precisely. Our work establishes the foundation to apply the cyclotron radiation emission spectroscopy (CRES) technique, developed by the Project 8 Collaboration, far beyond the 18-keV tritium endpoint region. We report initial measurements of β–’s from 6He and β+’s from 19Ne decays to demonstrate the broadband response of our detection system and assess potential systematic uncertainties for β spectroscopy over the full (MeV) energy range. To our knowledge, this is the first direct observation of cyclotron radiation from individual highly relativistic β’s in a waveguide. Furthermore, this work establishes the application of CRES to a variety of nuclei, opening its reach to searches for new physics beyond the TeV scale via precision β-decay measurements.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
The most precise determination of the neutron lifetime using the beam method was completed in 2005 and reported a result of τ(n)=(886.3±1.2stat±3.2syst) s. The dominant uncertainties were attributed ...to the absolute determination of the fluence of the neutron beam (2.7 s). The fluence was measured with a neutron monitor that counted the neutron-induced charged particles from absorption in a thin, well-characterized 6Li deposit. The detection efficiency of the monitor was calculated from the areal density of the deposit, the detector solid angle, and the evaluated nuclear data file, ENDF/B-VI 6Li(n,t)4He thermal neutron cross section. In the current work, we measure the detection efficiency of the same monitor used in the neutron lifetime measurement with a second, totally absorbing neutron detector. This direct approach does not rely on the 6Li(n,t)4He cross section or any other nuclear data. The detection efficiency is consistent with the value used in 2005 but is measured with a precision of 0.057%, which represents a fivefold improvement in the uncertainty. We verify the temporal stability of the neutron monitor through ancillary measurements, allowing us to apply the measured neutron monitor efficiency to the lifetime result from the 2005 experiment. The updated lifetime is τ(n)=(887.7±1.2stat±1.9syst) s.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UM
The aCORN backscatter-suppressed beta spectrometer Hassan, M.T.; Bateman, F.; Collett, B. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
09/2017, Volume:
867, Issue:
C
Journal Article
Peer reviewed
Open access
Backscatter of electrons from a beta detector, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a ...backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electron–antineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter veto detectors surrounds a plastic scintillator beta energy detector. The spectrometer contains an axial magnetic field gradient, so electrons are efficiently admitted but have a low probability for escaping back through the entrance after backscattering. The design, construction, calibration, and performance of the spectrometer are discussed.
Full text
Available for:
GEOZS, IJS, IMTLJ, KILJ, KISLJ, NUK, OILJ, PNG, SAZU, SBCE, SBJE, UL, UM, UPCLJ, UPUK, ZRSKP
We report a 0.08% measurement of the bound neutron scattering length of 4He using neutron interferometry. The result is b = (3.0982 ± 0.0021 stat ± 0.0014 syst) fm . The corresponding free atomic ...scattering length is a = (2.4746 ± 0.0017 stat ± 0.0011 syst) fm . With this result the world average becomes b = (3.0993 ± 0.0025) fm , a 2% downward shift and a reduction in uncertainty by more than a factor of six. Our result is in disagreement with a previous neutron interferometric measurement but is in good agreement with earlier measurements using neutron transmission.
Full text
Available for:
CMK, CTK, FMFMET, IJS, NUK, PNG, UL, UM